Microapproach Surgical Supplies Guiding Catheter Sheath

Price $50.00 Compare
Min Order 500 Pieces
Shipping From Guangdong, China
Popularity 433 people viewed
Quantity
+-
 

Shenzhen Microapproach Medical Technology Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
XB/MP
Surgical Supplies Materials
Plastic
Ethylene Oxide Sterilization
2 Years
Adult
Without Logo Printing
OEM/ODM
Interventional Procedure Surgery
3-4 Weeks
Class III
Medical Disposable/Consumable
Tiger Jl Jr Al Ar Pigtail
CE, ISO13485, FSC, Cfda
Implant Materials & Artificial Organs
MicroApproach
Sterile Bag+ Inner Box + Outer Carton
6F/8F
China
9018390000
Product Description

Guiding Catheters are intended for use for intravascular introduction of interventional/diagnostic devices into coronary or peripheral vascular systems.
 

 
1. Flat-wire-braided, 100-cm catheter shaft with PTFE liner
2. One-piece molded hub and strain relief
3. Curves designed for transradial access
4. Radiopaque for fluoroscopic visualization
5. Soft, radiused tip 
6. Ultra-thin tube with flat wire braid pattern to provide large lument for devices smooth delivery
7. Hydrophilic coating
8. Kink resistance


** Recommended Procedure

1) Remove the guiding catheter from its packaging using
sterile techniques.
2) Flush the guiding catheter lumen with a heparinized
saline solution.
3) Appropriate anticoagulation and vasodilation therapy
should be used.
4) Introduce the guiding catheter into the vasculature through
the catheter sheath introducer, and/or over an indwelling
guidewire using a percutaneous entry technique of choice.
5) Under fluoroscopic guidance, advance the guiding catheter over
the guidewire or introducer until the desired position is attained.
6) Remove the guidewire prior to introduction of other
intravascular devices or infusion of contrast agents.


** Complications
Use of guiding catheters should be restricted to those specialists trained to perform procedures for which the product is indicated.Complications may occur at any time during or after the procedure and may include, but are not limited to, the following: hemorrhage, hematoma, allergic reaction, infection, embolism, blood vessel dissection or occlusion.

Size comparison table of specifications and models
Terminal configuration    Size
Models
Nominal outer diameter
D1 (Fr/mm)
Internal diameter
D2 (mm)
Effective length
L(cm)
Multifunctional tube (XB)XB3.0-6-1006/2.061.80100
XB3.5-6-1006/2.061.80100
XB4.0-6-1006/2.061.80100
XB4.5-6-1006/2.061.80100
Multipurpose tube(MP)MPA1-8-908/2.672.1690
MPD-6-1006/2.061.80100

 
 