Multiparameter Sensor

Price Negotiable Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 315 people viewed
Quantity
+-
 

Suzhou Yosemite Technologies Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
Y4000
Input Type
Light Absorption Measurement
Contact
Digital Type
Integration
POM, Titanium Alloy, Anti-Fouling Copper
Liquid
IP68
ISO
Non-Customized
0-50ºC
Supports RS-485, Modbus Protocol
Complete Machine: DC 12-24V, ≥1A; Probe: 9-24V
IP 68
Yosemitech
Box
Φ 84mm*476mm
China
Product Description

 

Yosemitech Y4000 Multiparameter Sonde for Water Quality Monitoring adopts multi-in-one structure design, each single parameter sensor is RS485 digital probe and tightly inserted with the parent water surface, calibration data is stored in the single parameter sensor, which can be easily calibrated or replaced on site. Online monitoring of conventional 5 parameters (water temperature, pH/ORP, dissolved oxygen, conductivity, turbidity), can also monitor chlorophyll, blue-green algae, oil in water, etc., up to support a mother insert 6 probes, detect 7 parameters.

 

This Multi-Parameter Water Quality Probe also comes with a clean scraper, which can effectively clean the measurement end face, scrape out bubbles, prevent microbial attachment, and can calmly meet the monitoring needs of various water environment conditions such as sewage treatment, surface water, ocean and groundwater.

 

 

Features

- Digital sensor with RS485 output and standard MODBUS protocol

- All calibration parameters are stored in the sensor, and each probe is equipped with a waterproof connector for easy plug-in and replacement

- Equipped with a self-cleaning brush for regular cleaning at set intervals to eliminate errors caused by bubbles or contamination, suitable for long-term unattended online monitoring

- The main unit can be connected to up to 6 probes, allowing for the use of various sensors such as dissolved oxygen, conductivity (salinity), turbidity, pH, ORP, chlorophyll, blue-green algae, and oil in water

- Each sensor can be replaced, calibrated, and maintained on site, providing flexibility and convenience to users

- Efficient acquisition algorithm with a whole machine response time of ≤30s, main unit integrated voltage abnormal shutdown, communication abnormal alarm, and cleaning brush abnormal alarm for convenient operation and maintenance judgment.   

 

Product Parameters
NameOnline multi-parameter sensor
ModelY4000
Main body informationSupport up to 6 sensor access, 1 central cleaning brush, probe and cleaning brush can be disassembled, free combination
SizeΦ84mm*476mm
Operating temperature0-50ºC
Calibration dataThe calibration data is stored in the probe, which can be disassembled for direct calibration
OutputSupports RS-485, MODBUS protocol
Cleaning brushYes/Standard configuration
Brush controlThe default cleaning time is 30 minutes. the cleaning interval can be setted
Full load power consumption0.8W(non wiping), 2W(wiping)
Power supply requirementComplete machine:DC 12-24V,≥1A;probe:9-24V,≥1A
IP rangeIP68
MaterialPOM, titanium alloy, anti-fouling copper
Status alertInternal power supply exception alarm, internal communication exception alarm, and cleaning brush exception alarm
Cable lengthWith waterproof connector, 10m (default), customizable
Optional sensors
DOModelY504-BTurbidityModelY510-C
PrincipleFluorescence methodPrinciple90°Scattered light
Range0-20mg/L or 0-200% SaturationRange0.1-1000NTU
Accuracy±1% or ±0.3mg/L, (take the bigger one) Accuracy±5% or 0.3NTU,(take the bigger one)
Max depth40mMax depth40m
Electrical conductivity (salinity)ModelY521-BOil-in-waterModelY616-C
PrincipleFour-electrodePrincipleUltraviolet fluorescence method
Conductivity range0-5mS/cm or 0-100mS/cmRange0-150ppm
Salinity range0-2.5ppt or 0-80pptLinearityR²>0.999
Max depth40mMax depth40m
pHModelY532-BORPModelY533-B
PrincipleGlass electrode methodPrinciplePlatinum electrode method
Range0-14 pHRange-1999~1999mV
Accuracy±0.02 pHAccuracy±20mV
Max depth20mMax depth20m
ChlorophyllModelY515-BBlue-green algaeModelY613-C
PrincipleFluorescence methodPrincipleFluorescence method
Range0-500μg/LRange0-300,000 cells/mL(adjustable 0-2 million)
Accuracy±5% or 0.5μg/L,(take the bigger one)LinearityR²>0.999
Max depth40mMax depth40m
Message Type
* Message Content
* Name  
* Phone
* Email