Power Cable
Construction, Overhead, Underground, Power Station
Low and Medium Voltage Cable
DC & AC
XLPE
PVC
Round Wire
Copper&Aluminum
ISO, CCC, CE, RoHS
Yjv22&Yjv32&Yjlv22&Yjlv22
Hnbf Cable
1, 2, 3, 3+1, 3+2, 4+1, 5
Steel Wire&Steel Tape
Armoured Cable
Provide
12 Months
Fob, CIF, CFR
HNBF
Wodden Drum&Iron-Wooden Drum
0.75(sqmm),1.0,1.5,2.5,4,6,10,16,25,35,50,70.
Zhengzhou China
8544492100
Product Description
Product Description
XLPE Insulated Power Cable
Type | Description | Main application |
YJV/YJLV | Cu or Al conductor XLPE insulated PVC Sheath Power cable | For laying indoor and outdoor,unable to bear certain extermal mechanical force but the tractive force during laying.Laying Single core cable in magnetic duct is not permissble |
YJV22/YJLV22 | Cu or Al conductor XLPE insulated steel tape armored PVC sheathed power cable | For laying underground, bear external mechanical force, but unable to bear large pulling force |
YJV32/YJLV32 | Cu or Al conductor XLPE insulated thin steel wire armoured PVC sheathed power cable | For laying under ground, vertical well, or underwater, able to bear certain pulling force. |
a. Excellent electric and mechanical characteristics
b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant
c. Simple in structure,Convenient to use
d. Reduce costs
Rated Voltage of XLPE Cable
Extruded XLPE insulation with rated voltage from 0.6/1kv to 8.7/15kv
Conductor: Aluminium or Copper
Insulation: XLPE
Armoured: Galvanized steel tape,Galvanized steel wire
Outer Sheath: PVC OR PE
The number of core: 1,2,3,3+1,3+2,4+1,5
We will try our best to meet the customer's requirement.
* Max Permissible continous operating temperature of Conductors shall not exceed 90ºC
* Not exceeding 250ºC.(Max. Duration5 seconds)
* The lowest temperature of installation is 0ºC.
* Unable be laid without the limit of fall with enough mechanical pull,Single core cable can not be laid in iron tube or fixed by circled iron tools around cables





According to GB12706(Equal to IEC60502)
Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request.
single core
Normal cross-sectional area of conductor mm2 | Normal thickness of insulation mm | Normal thickness of sheath mm | Approx. overall diameter mm | Approx.Weight KG/KM | |||
YJV | YJY | YJLV | YJLY | ||||
1×1.5 | 0.7 | 1.4 | 6 | 47 | 37 | 38 | 28 |
1×2.5 | 0.7 | 1.4 | 6 | 59 | 49 | 44 | 33 |
1×4 | 0.7 | 1.4 | 7 | 77 | 65 | 52 | 40 |
1×6 | 0.7 | 1.4 | 7 | 99 | 86 | 62 | 49 |
1×10 | 0.7 | 1.4 | 8 | 147 | 131 | 84 | 68 |
1×16 | 0.7 | 1.4 | 9 | 209 | 191 | 109 | 91 |
1×25 | 0.9 | 1.4 | 11 | 304 | 283 | 149 | 127 |
1×35 | 0.9 | 1.4 | 12 | 400 | 377 | 184 | 160 |
1×50 | 1.0 | 1.4 | 13 | 524 | 498 | 232 | 205 |
1×70 | 1.1 | 1.4 | 15 | 732 | 701 | 310 | 279 |
1×95 | 1.1 | 1.5 | 17 | 991 | 953 | 404 | 367 |
1×120 | 1.2 | 1.5 | 18 | 1230 | 1189 | 490 | 449 |
1×150 | 1.4 | 1.6 | 20 | 1516 | 1467 | 603 | 554 |
1×185 | 1.6 | 1.7 | 23 | 1890 | 1832 | 748 | 690 |
1×240 | 1.7 | 1.8 | 26 | 2454 | 2384 | 954 | 884 |
1×300 | 1.8 | 1.8 | 28 | 3041 | 2965 | 1157 | 1081 |
two cores
Normal cross-sectional area of conductor mm2 | Normal thickness of insulation mm | Normal thickness of sheath mm | Approx. overall diameter mm | Approx.Weight KG/KM | |||
YJV | YJY | YJLV | YJLY | ||||
2×1.5 | 0.7 | 1.8 | 10 | 105 | 84 | 86 | 62 |
2×2.5 | 0.7 | 1.8 | 10 | 134 | 111 | 102 | 79 |
2×4 | 0.7 | 1.8 | 11 | 173 | 148 | 123 | 99 |
2×6 | 0.7 | 1.8 | 12 | 226 | 198 | 150 | 122 |
2×10 | 0.7 | 1.8 | 15 | 342 | 307 | 214 | 178 |
2×16 | 0.7 | 1.8 | 17 | 488 | 448 | 285 | 244 |
2×25 | 0.9 | 1.8 | 21 | 711 | 663 | 393 | 345 |
2×35 | 0.9 | 1.8 | 23 | 927 | 873 | 486 | 433 |
2×50 | 1.0 | 1.8 | 21 | 1096 | 1045 | 499 | 448 |
2×70 | 1.1 | 1.8 | 23 | 1518 | 1460 | 657 | 598 |
three cores
Normal cross-sectional area of conductor mm2 | Normal thickness of insulation mm | Normal thickness of sheath mm | Approx. overall diameter mm | Approx.Weight KG/KM | |||
YJV | YJY | YJLV | YJLY | ||||
3×1.5 | 0.7 | 1.8 | 10 | 127 | 105 | 99 | 77 |
3×2.5 | 0.7 | 1.8 | 11 | 167 | 143 | 120 | 96 |
3×4 | 0.7 | 1.8 | 12 | 221 | 194 | 145 | 118 |
3×6 | 0.7 | 1.8 | 13 | 293 | 263 | 179 | 149 |
3×10 | 0.7 | 1.8 | 16 | 445 | 408 | 253 | 215 |
3×16 | 0.7 | 1.8 | 18 | 647 | 604 | 342 | 299 |
3×25 | 0.9 | 1.8 | 22 | 959 | 908 | 482 | 431 |
3×35 | 0.9 | 1.8 | 24 | 1274 | 1217 | 613 | 556 |
3×50 | 1.0 | 1.8 | 24 | 1590 | 1530 | 695 | 634 |
3×70 | 1.1 | 1.8 | 28 | 2228 | 2154 | 935 | 861 |
3×95 | 1.1 | 2.0 | 31 | 3015 | 2927 | 1220 | 1132 |
3×120 | 1.2 | 2.1 | 34 | 3763 | 3661 | 1497 | 1396 |
3×150 | 1.4 | 2.3 | 38 | 4965 | 4533 | 1861 | 1738 |
3×185 | 1.6 | 2.4 | 42 | 5778 | 5636 | 2281 | 2138 |
3×240 | 1.7 | 2.6 | 47 | 7513 | 7339 | 2920 | 2746 |
3×300 | 1.8 | 2.8 | 52 | 9409 | 9202 | 3642 | 3535 |
four cores
Normal cross-sectional area of conductor mm2 | Normal thickness of insulation mm | Normal thickness of sheath mm | Approx. overall diameter mm | Approx.Weight KG/KM | |||
YJV | YJY | YJLV | YJLY | ||||
4×1.5 | 0.7 | 1.8 | 11 | 154 | 130 | 117 | 93 |
4×2.5 | 0.7 | 1.8 | 12 | 204 | 177 | 142 | 109 |
4×4 | 0.7 | 1.8 | 13 | 274 | 245 | 175 | 146 |
4×6 | 0.7 | 1.8 | 14 | 363 | 330 | 214 | 181 |
4×10 | 0.7 | 1.8 | 17 | 559 | 518 | 307 | 266 |
4×16 | 0.7 | 1.8 | 20 | 815 | 767 | 416 | 368 |
4×25 | 0.9 | 1.8 | 25 | 1208 | 1151 | 585 | 528 |
4×35 | 0.9 | 1.8 | 27 | 1612 | 1549 | 747 | 684 |
4×50 | 1.0 | 1.9 | 28 | 2057 | 1983 | 886 | 812 |
five cores
Normal cross-sectional area of conductor mm2 | Normal thickness of insulation mm | Normal thickness of sheath mm | Approx. overall diameter mm | Approx.Weight KG/KM | |||
YJV | YJY | YJLV | YJLY | ||||
5×4 | 0.7 | 1.8 | 14 | 332 | 300 | 206 | 174 |
5×6 | 0.7 | 1.8 | 15 | 446 | 410 | 256 | 220 |
5×10 | 0.7 | 1.8 | 19 | 691 | 646 | 370 | 325 |
5×16 | 0.7 | 1.8 | 22 | 1007 | 954 | 499 | 446 |
5×25 | 0.9 | 1.8 | 25 | 1504 | 1441 | 710 | 835 |
5×35 | 0.9 | 1.8 | 28 | 2007 | 1937 | 905 | 947 |
5×50 | 1.0 | 2.0 | 33 | 2726 | 2634 | 1234 | 1142 |
5×70 | 1.1 | 2.1 | 37 | 3823 | 3712 | 1669 | 1558 |
5×95 | 1.1 | 2.3 | 43 | 5190 | 5050 | 2199 | 2059 |
5×120 | 1.2 | 2.4 | 48 | 6349 | 6187 | 2575 | 2413 |
5×150 | 1.4 | 2.6 | 53 | 7869 | 7673 | 3213 | 3017 |
5×185 | 1.6 | 2.8 | 59 | 9788 | 9552 | 3962 | 3726 |
5×240 | 1.7 | 3.0 | 67 | 12849 | 12564 | 5198 | 4913 |
5×300 | 1.8 | 3.2 | 74 | 15920 | 15584 | 6314 | 5978 |


*Henan Baofeng Cable Co., Ltd. is a professional cable & wire manufacturer which integrates R&D, production and sales together.
*Our products sales network has covered more than 20 provinces and municipalities in China. Most of products are sold to many countries for overseas marketing including the following areas like Philippines, Indonesia, Bangladesh, UK, Congo, Iran, Australia, Tanzania, USA, Madagascar, Pakistan, South Africa, Tunis, Dominica, Honduras, Guatemala, Iraq, Chile, Brazil, Peru etc.

Our Package& delivery
Our company will design very reasonable packaging and very strong.
Our company will provide excellent service and guarantee the timeliness of supply.

Why Choose Us
1. Strict quality control system, excellent quality with reasonable price.
2. Strong and professional R&D team to meet your specific needs.
3. Rapid delivery and feedback. Faster lead time than our competitors.
4. OEM service available based on offical & legal authorization.
5. Prouducts are various,and free sample is available.
6. Appointed shipping company is acceptable.