T-ZSTZ 80 Q5 J
Upright, Pendent
Closed
Wet Alarm Valve
Can Automatically Opened and Closed
Deluge System
Wet Fire Sprinkler System
Differential Type
Seat Type
100mm
K5.6; K8.0: K11.2
Diaphragm Type
K5.6; K8.0: K11.2 Fire Sprinkler
Chrome; Original
3/4''; 1/2''; Bsp/NPT
Brass
68 Degree
Workable, MOQ=5000PCS
Cccf, ISO9001, ISO14001
FOREDE
Carton
65*50*50
Fujian, China
8424901000
Product Description
K=5.6/8.0 FIRE SPRINKLER
A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by properly designed and maintained fire sprinklers, over 99% of fires were controlled by fire sprinklers alone.
K=11.2 FIRE SPRINKLER
FOREDE Series FRD004/FRD005 11.2K Standard Response, Standard Coverage Upright and Pendent Sprinklers are automatic sprinklers of the frangible bulb type. They are standard response, spray sprinklers that produce a hemi-
spherical water distribution pattern below the deflector.
The 11.2 K-factor, FRD004/FRD005 Sprinklers were subjected to full-scale, high-piled storage fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor standard spray sprinklers for the protection of high-piled storage.
Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, FRD004/FRD005 Sprinklers, making their use highly advantageous in high density applications, such as the protection of high-piled storage.
Chrome coatings can be used to extend the life of the brass components used in Series FRD004/FRD005 Sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end-user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed.




A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by properly designed and maintained fire sprinklers, over 99% of fires were controlled by fire sprinklers alone.
K=11.2 FIRE SPRINKLER
FOREDE Series FRD004/FRD005 11.2K Standard Response, Standard Coverage Upright and Pendent Sprinklers are automatic sprinklers of the frangible bulb type. They are standard response, spray sprinklers that produce a hemi-
spherical water distribution pattern below the deflector.
The 11.2 K-factor, FRD004/FRD005 Sprinklers were subjected to full-scale, high-piled storage fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor standard spray sprinklers for the protection of high-piled storage.
Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, FRD004/FRD005 Sprinklers, making their use highly advantageous in high density applications, such as the protection of high-piled storage.
Chrome coatings can be used to extend the life of the brass components used in Series FRD004/FRD005 Sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although coated sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end-user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed.
K=5.6/8.0 FIRE SPRINKLER

K=11.2 FIRE SPRINKLER


Model | FRD001 | FRD002 | FRD003 | FRD004 | FRD005 | FRD006 |
Style | Pendent | Upright | Sidewall | Pendent | Upright | Sidewall |
Response | Standard response | Quick response | ||||
Response Temp. | 68°C/155°F | |||||
Working Pressure | 1.2 MPa/12 bar | |||||
Normal Diameter | DN15; DN20 | |||||
Thread | BSP / NPT | |||||
K Factor | 80 @metric (5.6@US); 115 @metric (8.0@US) | |||||
Material | Brass frame,brass deflector,Glass bulb,Teflon (PTFE) plated metal sealing ring |
K=11.2 FIRE SPRINKLER


TECHNICAL DATA
Physical Characteristics
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Sealing Assembly Glass bulb 5mm. . . . . .Glass
Physical Characteristics
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Cap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Sealing Assembly Glass bulb 5mm. . . . . .Glass
Compression Screw . . . . . . . . . . . . . . . . .Brass
Deflector . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Refer to TABLE A & TABLE B for additional technical data.
TABLE B | |
MODEL | FRD005 |
WORKING PRESSURE | 175 psi (12,1 bar) |
CONNECTION | 3/4'' BSP (NPT OPTIONAL) |
K-FACTOR | 11.2 GPM/psi½ (161,4 LPM/bar½) |
TEMPERATURE RATING | 155 ºF (68 ºC) 200 ºF (93 ºC) 286 ºF (141 ºC) |
INSTALLATION | Pendent |




How To Cooperate With Us?
Dear Customer,
Before ordering, please contact with our sales team to discuss order information, such as Model Number, Flow Rate, Material, Control Ways, Package,Etc.
If you have any other requirements or wanna know more info about our products, welcome to contact as well. Our Sales team and Technical Department are willing to support you.
Our address
Nan'an City, Quanzhou City Fujian PRC-China
Dear Customer,
Before ordering, please contact with our sales team to discuss order information, such as Model Number, Flow Rate, Material, Control Ways, Package,Etc.
If you have any other requirements or wanna know more info about our products, welcome to contact as well. Our Sales team and Technical Department are willing to support you.
Our address
Nan'an City, Quanzhou City Fujian PRC-China