Features | - Compared with other brands of the planetary centrifugal mixer, MSK-PCV-300 has the following unique features:
- Mixing under vacuum for deaeration
- Dual containers for larger quantity
- Minimized contamination (no metal mixing blade)
- Sample Materials
- Nanopowders, ceramic powders
- Grease
- Slurry
- Paste
|
Voltage Input | - Single Phase AC 208 - 240V, 50/60 Hz
|
Power | - Maximum: 2000 W
- Motor Power: 750 W
|
Mixing
| - Planetary Centrifugal Vacuum Mixing
- The centrifugal force of rotation and revolution induces convection, homogenizing the materials
- With the vacuum pressure, submicron air bubbles can be efficiently eliminated from the materials
|
Vacuum Capability | - Pumping Rate: 165 L/min
- Ultimate Vacuum: -95 kPa
- Built-in vacuum pump with integrated control
|
Speed | - Fixed speed ratio ( 0.6X between main plate revolution and container rotating )
- Sample Platen Rotation (revolution motion):600 rpm - 2,000 rpm (adjustable)
- Container Spin (rotation motion):360 rpm - 1,200 RPM (fixed at 0.6X of the revolution speed)
|
Containers and Counter-Weights | - Two standard containers and counter-weights are included
- Two 300 mL containers with gas vent, made of high-density Polyethylene ( Pic 1, 2 )
- Counter-weights (10, 20, 50 g) with adapter, made of high-density Polyethylene (pic 3)
- For ball milling application, please choose stainless steel liner, which will reduce jar compacity to 200 ml ( Pic 4)
Pic. 1 Pic.2 Pic. 3 Pic. 4 |
Optional | - Optional containers, which can be ordered at MTI at extra cost:
- Two 100 mL containers (not included) with adapter and gas vent, made of high-density Polyethylene
- Two 30 mL containers (not included) with adapter and gas vent, made of high-density Polyethylene
- 26 mm Dia. adapter for 30 mL syringe (not included), made of high-density Polyethylene
- Two 3-container-sets (7 ml, 16 mm ID x 90 mm H) in one adapter are available for high throughput research (6 samples per batch)
- You may order stainless steel container for ball milling application (Pic second to the right)
- You may also order stainless steel container with a thicker wall for smaller sized ball milling application (the rightmost pic)
|
Max. Mixing Volume and Weight | Container | Max Sample Volume | Max Sample Weight | Max Gross Weight (Container Included) | 300 mL | 150 mL | 140 g | 300 g | 100 mL | 50 mL | 45 g | 80 g (adapter not included) | 80 mL(SS) | 60 mL | 90 g | 300 g (adapter included) | 30 mL | 15 mL | 12 g | 20 g (adapter not included) |
- Attention: Sample overload might damage the motor and/or cause spilling. Follow both the volume and weight limit when loading the
|
Program | - Store up to 6 programs in memory, as shown in Fig.1
- 3 programmable segments, as shown in Fig.2. For example:
- 800 rpm revolution speed (480 rpm rotation speed) for 60 sec;
- 1500 rpm revolution speed (900 rpm rotation speed) for 180 sec;
- 1000 rpm revolution speed (600 rpm rotation speed) for 60 sec.
- Maximum running time for each segment is 200 sec. Maximum total running time is 600 sec
- The rotation direction could be either clockwise (mode A) or counter-clockwise (mode B)
Fig.1 Fig.2 |
Safety and Protection | - Safety warning and interlocks are integrated. The unit automatically stops when
- The unit is overloaded with the sample
- The sample is loaded in an unbalanced way
- The top cover is opened
|
Warranty | - One year limited standard warranty with lifetime technical support
|
Dimension | - 400 mm (W) x 590 mm (H) x 580 mm (D)
-
|
Weight | |
Shipping Weight & Dimensions | |
Application Notes | - Always use the mixer on level & stable surface for best performance and maximum safety
- Do not use the mixer in a hazardous atmosphere, or with flammable, explosive, corrosive, poisonous material! Check the chemical resistanceof the container with the different material before loading the sample!!!
- Do not overload the mixer! Stop the mixing operation immediately if abnormal sound/vibration are observed
- Use a digital balance to make sure the sample loading is balanced before mixing
- Double check if the containers are mounted correctly and securely before mixing
- Do not open the cover lid until the rotation has completely stopped! Do not retrieve the containers and/or put hand close to mixing fixture while the rotation has not completely stopped!
- Only use the included containers for the mixing operation! Double check to make sure there is no foreign object in the mixer before mixing
- Please click underline to learn Centrifugal Force calculation.
|