18/20kv 3-Cores Cold Shrinkable Outdoor Termination Kits Cold Shrinkable Cable Termination

Price $74.29 Compare
Min Order 10 Sets
Shipping From Jiangsu, China
Popularity 329 people viewed
Quantity
+-
 

Suzhou Jiuwei Electric Made Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
VLZ / VLJ / VLN / VLW
Cable Accessories
Silicone Rubber
Cable Connection
Insulation
Terminal
Injection Molding
Tbd
Tbd
CNAS
9V
LV & Mv (up to 18/20kv)
Grey
Pass
Not Flashover and Not Breakdown
9V
Carton
Customized
Jiangsu, China
8547909000
Product Description
Product Description

  Cold-shrinkable cable termination kit & straight joint kit

This product adopts high quality liquid silicone rubber,The excellent performance, stress control material, and strong resistance to electric traces will make the cold shrinkable cable accessories become the first choice in the industry.
Advantages include installation without fire, construction time and space saving, a model can be applied to a variety of cable diameter.
Detailed Photos
 
Product Parameters

0.6/1KV-Cold Shrinkable Cable Accessories

NameItem No.Suit cables' sectional area (sqmm)NameItem No.Suit cables' sectional area (sqmm)
0.6/1kV 3-cores Cold Shrinkable Termination KitsVLZ-1/3.010~160.6/1kV 3-cores Cold Shrinkable JointVLJ-1/3.010~16
VLZ-1/3.125~50VLJ-1/3.125~50
VLZ-1/3.270~120VLJ-1/3.270~120
VLZ-1/3.3150~240VLJ-1/3.3150~240
VLZ-1/3.4300~400VLJ-1/3.4300~400
0.6/1kV 4-cores Cold Shrinkable Termination KitsVLZ-1/4.010~160.6/1kV 4-cores Cold Shrinkable JointVLJ-1/4.010~16
VLZ-1/4.125~50VLJ-1/4.125~50
VLZ-1/4.270~120VLJ-1/4.270~120
VLZ-1/4.3150~240VLJ-1/4.3150~240
VLZ-1/4.4300~400VLJ-1/4.4300~400
0.6/1kV 5-cores Cold Shrinkable Termination KitsVLZ-1/5.010~160.6/1kV 5-cores Cold Shrinkable JointVLJ-1/5.010~16
VLZ-1/5.125~50VLJ-1/5.125~50
VLZ-1/5.270~120VLJ-1/5.270~120
VLZ-1/5.3150~240VLJ-1/5.3150~240
VLZ-1/5.4300~400VLJ-1/5.4300~400
 
Test ProjectStandard RequirementsTest Result/Conclusion
Power Frequency Voltage Test4kV/1min,No breakdown no flashoverPass,meet the requirements
Power Frequency Voltage Test2.4kV/4 hours,No breakdown no flashoverPass,meet the requirements
 
8.7/15KV-Cold Shrinkable Cable Accessories
NameItem No.Suit cables' sectional area (sqmm)NameItem No.Suit cables' sectional area (sqmm)
8.7/15kV 3-cores Cold Shrinkable Indoor Termination KitsVLN-10/3.125~508.7/15kV Single Core Cold Shrinkable Indoor Termination KitsVLN-10/1.125~50
VLN-10/3.270~120VLN-10/1.270~120
VLN-10/3.3150~240VLN-10/1.3150~240
VLN-10/3.4300~400VLN-10/1.4300~400
VLN-10/3.5500~630VLN-10/1.5500~630
8.7/15kV 3-cores Cold Shrinkable Outdoor Termination KitsVLW-10/3.125~508.7/15kV Single Core Cold Shrinkable Outdoor Termination KitsVLW-10/1.125~50
VLW-10/3.270~120VLW-10/1.270~120
VLW-10/3.3150~240VLW-10/1.3150~240
VLW-10/3.4300~400VLW-10/1.4300~400
VLW-10/3.5500~630VLW-10/1.5500~630
8.7/15kV 3-cores Cold Shrinkable JointVLJ-10/3.125~508.7/15kV Single Core Cold Shrinkable JointVLJ-10/1.125~50
VLJ-10/3.270~120VLJ-10/1.270~120
VLJ-10/3.3150~240VLJ-10/1.3150~240
VLJ-10/3.4300~400VLJ-10/1.4300~400
VLJ-10/3.5500~630VLJ-10/1.5500~630
Test ProjectStandard RequirementsTest Result/Conclusion
Power Frequency Voltage39kV 5min Not Flashover and Not BreakdownPass
Partial DischargeUnder 15kV, Discharge volume≤10pcPass
Impulse Voltage TestUnder 95kV, ±10 times,No breakdown no flashoverNot Flashover and Not Breakdown
Constant Voltage load Cycle (in air)The conductor applied voltage 23kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cyclesNot Flashover and assessed by the following test results
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC)Under 15kV, Discharge volume≤10pcPass
Constant load Cycle TestThe conductor applied voltage 23kV, and heated to (95-100ºC). In which the temperature stability 2h, cooling 3h, a total of 60 cyclesNot Flashover and assessed by the following test results
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC,and at ambient temperature)Under 15kV, Discharge volume≤10pcPass
Thermal Stability TestUnder 23 KA, Short circuit 2 times, No visible damagePass
Dynamic Stability TestUnder 81 KA, Short circuit 1 time, No visible damagePass
Impulse Voltage Test95kV, ±10 timesNot Flashover and Not Breakdown
AC Withstand Voltage23kV, 15minNot Flashover and Not Breakdown
Tide Temperature Test11kV, 300hNot Flashover,Not Breakdown and No Overcurrent Release
Salt Spray Test11kV, 1000hNot Flashover,Not Breakdown and No Overcurrent Release
 
12/20KV 18/20KV-Cold Shrinkable Cable Accessories
NameItem No.Suit cables' sectional area (sqmm)NameItem No.Suit cables' sectional area (sqmm)
18/20kV 3-cores Cold Shrinkable Indoor Termination KitsVLN-20/3.135~7018/20kV Single Core Cold Shrinkable Indoor Termination KitsVLN-10/1.135~70
VLN-20/3.295~185VLN-10/1.295~185
VLN-20/3.3240~400VLN-10/1.3240~400
VLN-20/3.4500~630VLN-10/1.4500~630
18/20kV 3-cores Cold Shrinkable Outdoor Termination KitsVLW-20/3.135~7018/20kV Single Core Cold Shrinkable Outdoor Termination KitsVLW-10/1.135~70
VLW-20/3.295~185VLW-10/1.295~185
VLW-20/3.3240~400VLW-10/1.3240~400
VLW-20/3.4500~630VLW-10/1.4500~630
18/20kV 3-cores Cold Shrinkable JointVLJ-20/3.135~7018/20kV Single Core Cold Shrinkable JointVLJ-10/1.135~70
VLJ-20/3.295~185VLJ-10/1.295~185
VLJ-20/3.3240~400VLJ-10/1.3240~400
VLJ-20/3.4500~630VLJ-10/1.4500~630
Test ProjectStandard RequirementsTest Result/Conclusion
Power Frequency Voltage54kV 5min Not Flashover and Not BreakdownPass
Partial DischargeUnder 20kV, Discharge volume≤10pcPass
Impulse Voltage TestUnder 125kV, ±10 times,No breakdown no flashoverNot Flashover and Not Breakdown
Constant Voltage load Cycle (in air)The conductor applied voltage 35kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cyclesNot Flashover and assessed by the following test results
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC)Under 20kV, Discharge volume≤10pcPass
Constant load Cycle TestThe conductor applied voltage 35kV, and heated to (95-100ºC). In which the temperature stability 2h, cooling 3h, a total of 60 cyclesNot Flashover and assessed by the following test results
Partial Discharge (the normal operation of the high temperature and conductor 5-10ºC,and at ambient temperature)Under 20kV, Discharge volume≤10pcPass
Thermal Stability TestUnder 23 KA, Short circuit 2 times, No visible damagePass
Dynamic Stability TestUnder 81 KA, Short circuit 1 time, No visible damagePass
Impulse Voltage Test125kV, ±10 timesNot Flashover and Not Breakdown
AC Withstand Voltage30kV, 15minNot Flashover and Not Breakdown
Tide Temperature Test15kV, 300hNot Flashover,Not Breakdown and No Overcurrent Release
Salt Spray Test15kV, 1000hNot Flashover,Not Breakdown and No Overcurrent Release
 
26/35KV-Cold Shrinkable Cable Accessories
NameItem No.Suit cables' sectional area (sqmm)NameItem No.Suit cables' sectional area (sqmm)
26/35kV 3-cores Cold Shrinkable Indoor Termination KitsVLN-35/3.150~9526/35kV Single Core Cold Shrinkable Indoor Termination KitsVLN-35/1.135~70
VLN-35/3.2120~185VLN-35/1.295~185
VLN-35/3.3240~400VLN-35/1.3240~400
VLN-35/3.4500~630VLN-35/1.4500~630
26/35kV 3-cores Cold Shrinkable Outdoor Termination KitsVLW-35/3.150~9526/35kV Single Core Cold Shrinkable Outdoor Termination KitsVLW-35/1.135~70
VLW-35/3.2120~185VLW-35/1.295~185
VLW-35/3.3240~400VLW-35/1.3240~400
VLW-35/3.4500~630VLW-35/1.4500~630
26/35kV 3-cores Cold Shrinkable JointVLJ-35/3.150~9526/35kV Single Core Cold Shrinkable JointVLJ-35/1.135~70
VLJ-35/3.2120~185VLJ-35/1.295~185
VLJ-35/3.3240~400VLJ-35/1.3240~400
VLJ-35/3.4500~630VLJ-35/1.4500~630
Test ProjectStandard RequirementsTest Result/Conclusion
Power Frequency Voltage105kV 1min Not Flashover and Not BreakdownPass
Partial DischargeUnder 39kV, Discharge volume≤10pcPass
Constant Voltage load Cycle (in air)The conductor applied voltage 23kV,and heated to (95-100ºC). In which the temperature stability 2h,cooling 3h, a total of 3 cyclesNot Flashover and assessed by the following test results
Impulse Voltage TestUnder 250kV, ±10 times,No breakdown no flashoverNot Flashover and Not Breakdown
DC Voltage156kV, 15minNot Flashover and Not Breakdown
AC Withstand Voltage104kV, 4hNot Flashover and Not Breakdown
Recommended Product

View more products,you can click photos...

 

      66~500kV High Voltage Cable Accessories                 1~35kV Heat Shrink Cable Accessories                                     Grounding Box

        Customized Silicone Rubber Protector                                Heat Shrinkable Tubing                                                  Explosion Proof Box

Company Profile
Packaging & Shipping
FAQ
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA