LADX-COPP-ZR
Data Center Enterprise, Communication Transmision
Ethernet
CE, ISO, RoHS, FCC Reach
New
Ethernet
CE, ISO, RoHS, FCC Reach
New
Data Center Enterprise, Communication Transmision
Both Single Mode and Multi Mode
Linksall
Blister Pack
China
8517706000
Product Description
10G Base-T Copper SFP transceiver module
Features
- Support 10GBASE-T Operation in Host Systems
- Support RX_LOS as Link indication function
- Hot-Pluggable SFP Footprint
- Compact RJ-45 Connector Assembly
- Compliant with SFP MSA
- Operating Case Temperature: 0ºC~70ºC
Applications
- 10G BASE-T IEEE 802.3an
- 1000BASE-T IEEE 802.3ab
- 100BASE-TX IEEE 802.3u
- 5G MGBASE-T
- 2.5G MGBASE-T
Product Description
UNSFP-10G-T, 10G BASE-T Copper Small Form Pluggable (SFP) modules are based on the SFP Multi Source Agreement (MSA). It is compliant with the 10G BASE-T, 1000BASE-T, 100BASE-TX standards as specified in IEEE STD 802.3an, 802.3ab and 802.3au.Absolute Maximum Ratings*
Parameter | Symbol | Min | Type | Max | Units |
Maximum Supply Voltage | Vcc | -0.5 | 4.0 | V | |
Storage Temperature | TS | -40 | 85 | °C |
Normal operating condition
Parameter | Symbol | Min | Type | Max | Units | |
Operating Case Temperature | Tc | UNSFP-10G-T | 0 | 70 | °C | |
Supply Voltage | Vcc | 3.14 | 3.3 | 3.46 | V | |
Regulatory Compliance*Note1
Product Certificate | Certificate Number | Applicable Standard |
TUV | R50135086 | EN 60950-1:2006+A11+A1+A12+A2 |
EN 60825-1:2014 | ||
EN 60825-2:2004+A1+A2 | ||
UL | E317337 | UL 60950-1 |
CSA C22.2 No. 60950-1-07 | ||
EMC CE | AE 50285865 0001 | EN 55022:2010 |
EN 55024:2010 | ||
FCC | WTF14F0514417E | 47 CFR PART 15 OCT., 2013 |
FDA | / | CDRH 1040.10 |
ROHS | / | 2011/65/EU |
Electrical Characteristics
Parameter | Symbol | Min | Typ | Max | Units | Notes/Conditions |
+3.3 Volt Electrical Power Interface | ||||||
Supply Current | Icc | 800 | mA | |||
Input Voltage | Vcc | 3.13 | 3.3 | 3.47 | V | |
Low-Speed Signals, Electronic Characteristics | ||||||
SFP Output LOW | VOL | 0 | 0.5 | V | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector | |
SFP Output HIGH | OH | host_ Vcc - 0.5 | host_ Vcc + 0.3 | V | 4.7k to 10k pull-up to host_Vcc, measured at host side of connector | |
SFP Input LOW | VIL | 0 | 0.8 | V | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector | |
SFP Input HIGH | VIH | 2 | Vcc + 0.3 | V | 4.7k to 10k pull-up to Vcc, measured at SFP side of connector | |
High-Speed Electrical Interface, Transmission Line-SFP | ||||||
Tx Output impedance | Zout,TX | 100 | Ohm | Differential, for all frequencies between 1MHz and 125MHz | ||
Rx Input Impedance | Zin,RX | 100 | Ohm | Differential, for all frequencies between 1MHz and 125MHz | ||
High-Speed Electrical Interface, Host-SFP | ||||||
Single ended data input swing | Vin | 250 | 1200 | mV | Single ended | |
Single ended data output swing | Vout | 350 | 800 | mV | Single ended | |
Rise/Fall Time | Tr,Tf | 20 | psec | 20%-80% | ||
Tx Input Impedance | Zin | 50 | Ohm | Single ended | ||
Rx Output Impedance | Zout | 50 | Ohm | Single ended |
Pin Descriptions
Pin No. | Name | Function | Plug Seq. | Notes |
1 | VeeT | Transmitter Ground | 1 | |
2 | TX Fault | Transmitter Fault Indication | 3 | Not used |
3 | TX Disable | Transmitter Disable | 3 | 1 |
4 | MOD-DEF2 | Module Definition 2 | 3 | 2 |
5 | MOD-DEF1 | Module Definition 1 | 3 | 2 |
6 | MOD-DEF0 | Module Definition 0 | 3 | 2 |
7 | RS0 | No Connection required | 3 | |
8 | LOS | Loss of Signal | 3 | RX_LOSS |
9 | RS1 | No Connection required | 1 | |
10 | VeeR | Receiver Ground | 1 | |
11 | VeeR | Receiver Ground | 1 | |
12 | RD- | Inv. Received Data Out | 3 | |
13 | RD+ | Received Data Out | 3 | |
14 | VeeR | Receiver Ground | 1 | |
15 | VccR | Receiver Power | 2 | |
16 | VccT | Transmitter Power | 2 | |
17 | VeeT | Transmitter Ground | 1 | |
18 | TD+ | Transmit Data In | 3 | |
19 | TD- | Inv. Transmit Data In | 3 | |
20 | VeeT | Transmitter Ground | 1 |
- PHY disabled on TDIS > 2.0V or open, enabled on TDIS < 0.8V, used to reset the module.
- Should be pulled up with 4.7k - 10k Ohm on host board to a voltage between 2.0 V and 3.6 V. MOD_DEF(0) pulls line low to indicate module is plugged in.Serial Communication Protocol
UNSFP-10G-T support the 2-wire serial communication protocol outlined in the SFP MSA, These SFP use a 128 byte EEPROM with an address of A0H.
EEPROM Serial ID Memory Contents
Accessing Serial ID Memory uses the 2 wire address 1010000X (A0H). Memory Contents of Serial ID are shown in Table 1.Table 1 Serial ID Memory Contents
Addr. | Size (Bytes) | Name of Field | Hex | Description | |||
BASE ID FIELDS | |||||||
0 | 1 | Identifier | 03 | SFP | |||
1 | 1 | Ext. Identifier | 04 | SFP function is defined by serial ID only | |||
2 | 1 | Connector | 07 | -LC | |||
3-10 | 8 | Transceiver | 10 00 00 00 00 00 00 00 | Transmitter Code | |||
11 | 1 | Encoding | 06 | 64B/66B | |||
12 | 1 | BR, Nominal | 67 | 10.3G | |||
13 | 1 | Reserved | 00 | - | |||
14 | 1 | Length (9µm)km | 00 | ||||
15 | 1 | Length(9µm)100m | 00 | ||||
16 | 1 | Length (50µm) 10m | 08 | 80m | |||
17 | 1 | Length(62.5µm)10m | 02 | 20m | |||
18 | 1 | Length (Copper) | 00 | ||||
19 | 1 | Reserved | 1E | 300m | |||
20-35 | 16 | Vendor name | XX XX XX XX XX XX XX XX(note2)20 20 20 20 20 20 20 20 | Vendor name (ASCII) | |||
36 | 1 | Reserved | 00 | - | |||
37-39 | 3 | Vendor OUI | XX XX XX(note2) | - | |||
40-55 | 16 | Vendor PN | XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX(note2) | Transceiver part number | |||
56-59 | 4 | Vendor rev | XX XX XX XX(note2) | - | |||
60-61 | 2 | Wavelength | 03 52 | -850nm | |||
62 | 1 | Reserved | 00 | - | |||
63 | 1 | CC_BASE | Check Sum (Variable) | Check code for Base ID Fields | |||
EXTENDED ID FIELDS | |||||||
64-65 | 2 | Options | 00 1A | TX_DISABLE, TX_FAULT and Loss of Signal implemented. | |||
66 | 1 | BR, max | 00 | ||||
67 | 1 | BR, min | 00 | ||||
68-83 | 16 | Vendor SN | XX XX XX XX XX XX XX XX 20 20 20 20 20 20 20 20(note2) | Serial Number of transceiver (ASCII). For example "B000822". | |||
84-91 | 8 | Date code | XX XX XX XX XX XX XX XX(note2) | Manufactory date code. For example "080405". | |||
92 | 1 | Diagnostic Monitoring Type | XX(note2) | Digital diagnostic monitoring implemented | |||
93 | 1 | Enhanced Options | XX(note2) | Optional flags | |||
94 | 1 | SFF_8472 Compliance | XX(note2) | 01 for diagnostics (Rev9.3 SFF-8472). | |||
95 | 1 | CC_EXT | Check Sum | Check sum for Extended ID | |||
(Variable) | Field. | ||||||
VENDOR SPECIFIC ID FIELDS | |||||||
96-127 | 32 | Vendor Specific | Read only | Depends on customer information | |||
128-255 | 128 | Reserved | Read only | - | |||
Order Information
Part No. | Data Rate | Media type | Distance | Connector | Temperature |
UNSFP-10G-T* Note3 | 10G | CAT6A/CAT7 | 30m | RJ45 | Standard |
*The product image only for reference purpose.