72.5kv/630~1250A Oip Condenser Transformer Bushing (Draw lead) Brdlw

Price $80000.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 389 people viewed
Quantity
+-
 

Ningbo Ville Electric Co., Ltd.

VIP   Audited Supplier 17 years
Profile Certified by SGS/BV
BRDLW-72.5-1250-4
Power
Three
Core-type Transformer
Oil-immersed Type Transformer
Two-winding Transformer
ISO9001
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Ville
Porcelain
Bushing Insulator
B Type Insulator
Trough Type
5000n
Brown
Enter Value Here (e.g.: 12 Inches)
72.5kv
630~1250A
Short Tail Bushing
VILLE
Wooden Cases
IEC
Made in China
85
Product Description
Technical parameters:
Main properties
electric properties 
System nominal voltage Un(Kv)3566110132150220
Rated voltage Ur(Kv)40.572.5126145170252
60s power frequency withstand voltage:Dry kv95147230275325460
Wet Kv80140230275325460
Lightning impulse withstand voltage chopped waveFull wave Kv(peak)2003255506507501050
Kv(peak) 3756357508651210
Operating impulse withstand voltage(dry or wet)                                850
dielectric dissipation factor                     tanδ(20ºC temperature)Max.Ur:0.004
increment1.05Ur/√3-Ur:0.0005
Ur Partial discharge under voltage≤5pC
1.5Ur Partial discharge under voltage≤10pC
 
Bending testing load
Rated voltage Ur(Kv)Bending testing load(N)
Rated current Ir(A)
≤800800-16001600-2500≥3150
≤521250200020002500
72.51250125040004000
126-1703150400040004000
2524000500050005000
 
other properties
Item#Testingperformance index
1The bushing can withstand the gauge pressure of the sealing test at 0.2MPa no leakage
2interior tranformer oilPressure value(Kv)≥55
Dielectric loss factor tanδ(90ºC)≤0.004
Mico water(μg/g)≤10
ChromatographyAcetylene(μL/L)0
Hydrogen(μL/L)≤30
Total hydrocarbons(μL/L)≤9
3Measurement of Dielectric Loss Factor of Terminal to earth under 2kV voltage≤0.02
 
Type designation
BRDLW- (rated voltage:kV)/ (rated current:A)- (Antifouling grade)
BR-OIP Condenser transformer bushing,OIP Condenser wall bushing represent as CR
D-Short tail bushing,if no "D" it should be Medium-short tail bushing
L:can install CT
W:Antifouling type,3 means creepage distance is 25mm/kV,4 means creepage distance is 31mm/Kv
 
72.5Kv/630~1250A OIP Condenser transformer bushing(Draw lead)
CodeTypeRated voltage KvRated current
A
Main Dimensions(mm)Creepage distanceMASS KG
LL1L2L3L4L5D1D2D3d1d2d3d4AZX
BR4134ABRDLW-72.5/630-372.56301955165070067040035180138280283518144060120190088
BR4144ABRDLW-72.5/630-472.56302010170575567040035180138280283518144060120225092
BR4135ABRDLW-72.5/630-372.56302055175070077050035180138280283518144060120190088
BR4145ABRDLW-72.5/630-472.56302110180575577050035180138280283518144060120225086
BR4143ABRDLW-72.5/630-472.56301910160575557030035180138280283518144060120225088
BR4132ABRDLW-72.5/630-372.56301820161570053526535180138280283518144060120190081
BR4142ABRDLW-72.5/630-472.56301875157075553526535180138280283518144060120225087
BR4130ABRDLW-72.5/630-372.5630158512807003003035180138280283518144060120190075
BR4140ABRDLW-72.5/630-472.5630164013357553003035180138280283518144060120225080
BR4154ABRDLW-72.5/630-472.56302105180085067040035180138280283518144060120261098
BR4234ABRLW-72.5/1250-372.51250210018057008004504020016035036482418501101451900109
BR4244ABRLW-72.5/1250-472.51250215518607558004504020016035036482418501101452250118
BR4235ABRDLW-72.5/1250-372.51250210017057008005004020016035036482418501101401900106
BR4245ABRDLW-72.5/1250-472.51250215518607558005004020016035036482418501101402250114

Other HV bushing reference:








Package reference:


Ville Electric Company will keep up with the century, the epoch,


Sincerely look forward to your cooperation and win-win!

Create brilliant!