DS-161
Biochemical Apparatus
Biochemistry Analyzer
CE, MSDS, ISO13485
Brown
Small
SINNOWA
Wooden
China
9027509090
Product Description

Biochemistry Analyzer is designed for hospital or clinical laboratory to measure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.
Technical Specifications
Model | DS161 | |
Analytical System | Fully automatic, Random Access | |
Method | End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc | |
Assay Item | 30 assay | |
Throughput | 1 Reagent | 160 tests/hr |
2 Reagent | 100 tests/hr | |
Test Menu | T.BILI r-GT/GGT CHO Ca APOB-1/B CHE | |
D.BILI ALP/AKP TG CL APOB CREA | ||
TP UREA CK P CK-MB Mg | ||
ALB CREA LDH C ASO AFU | ||
Lactic Acid ALT/GPT UA α-HBDH CO2 FMN | ||
LP(a) AST/GOT GLU AMY LDL-C HDL-C | ||
CHE LA TBA ADA HS-CRP PA | ||
Fe Cu Zn C3 C4 IgG | ||
IgM IgA and drug, toxicity,etc. | ||
Sample Position | 50 | |
Including standard, control and STAT; either serum cup or primary tube available | ||
Sample Volume | 1~100ul, 0.1ul/step | |
Reagent Position | 36 | |
Reagent Volume | R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step | |
Reagent/Sample Probe | With liquid level sensor, collision sensor, Te flon coating and automatic washing station | |
Reaction Time | 0~999 seconds | |
Cuvette | High quality uv-transmitted plastic cuvette. | |
Cuvette Washing | 5 channels automatic washing system for reaction cuvettes | |
Probe and Mixer Washing | Independent washing station for each sample/reagent probe and mixer | |
Alarm | Automatic alarm for malfunction (eg: collision, reagent/sample insufficiency, full waste container, etc) | |
Calibration | Linear, Non-linear, Multi standard, K factor | |
Sample Dilution/Retest | Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function | |
Wavelength | 340-810nm | |
Light Source | Halogen lamp | |
Absorbance Resolution | 0.0001A | |
Absorbance Accuracy | ±0.0003A(0-2.5A) | |
Repeatability | ±2% | |
Quality Control | Levy jennings quality control program at 3 levels | |
Barcode | Optional | |
Printer | Multiple report formats available | |
System | Windows XP; Windows 7 | |
Power Supply | 220V or 110V, 50~60Hz | |
Dimension | 65×53×52(cm) | |
Weight | 45kg |
Features:
Random access fully automatic biochemistry analyzer
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection and collision protection for both sample and reagent probe
Reliable cooling system for reagent chamber
Powerful reaction cuvette washing system
barcode scanner (optional)
Lower waste and pro-environment
Structure:
1. Optical System
Light source: Halogen-tungsten lamp, 2000hours working life about
Wavelength: 340nm-810nm
Linear range:0~3ABS
2. Sample System
- Sample tray: 50 sample position,available to use serum cup or blood tube
- Sample volume:1~100ul, programmed by 0.1ul step
- Sample probe: Liquid level detection and collision protection automatically
- Probe cleaning: automatic washing both inside and outside, Carryover<0.1%
- Automatic sample dilution
- Reagent tray: 36 positions for single &dual Reagents.
- Refrigeration: Refrigerated reagent
- Compartment 24h Cooling system maintaining temperature 2~8°C
- Reagent volume:1~400ul, programmed by 0.1ul step
- Reagent probe: Liquid level detection and collision protection automatically
- Pre-heating function.
- Real-time monitoring of reagent volume and auto alarm
- Probe cleaning: automatic washing both inside and outside, Carry over<0.1%
- Reaction tray: 60 reaction cuvettes, High quality UV-transmitted plastic cuvettes adopt
- Back-Dividing-Light technology
- Min Reaction volume: 200ul
- Reaction Temperature:37°C+0.1°C
- Mixing system: Independent mixing probe
- Automatic washing cuvettes
- Automatic cleaning Sample/mixer probe
- Five channels washing station for each cuvette
- Automatic record and deduct cuvette blank value
Operation system: Windows XP, WIN 7, WIN 8
Interface: RS-232
7. Working Conditions
- Power Supply: 220V±10%, 50/60HZ; 110V (optional)
- Power consumption: ≤1200VA
- Temperature:15~30°C
- Humidity: ≤85%
- Water consumption: 4L/h
Certificates

Clients & Service
SINNOWA have had clients in more than 80 countries. We provide online service and training.

Packing & Shipping
Standard Shipping Wooden Package with foam materials inside.
Usually ship them by air, by sea or express.
Company Profile
Founded in 2002, SINNOWA specializes in developing, manufacturing and marketing IVD devices and reagents. We have two plants with GMP standard workshop and multiple production lines. Professionals from biomedical, chemical, mechanical control and automatic control are providing more convenient and reliable diagnostic solutions and service for in vitro diagnostic industry.

SINNOWA Medical Science & Tehcnology Co., Ltd.
No.7 Baoshan Road, Qilin, Nanjing, China