Fully-Auto Biochemistry Analyzer

Price $4500.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 390 people viewed
Quantity
+-
 

SINNOWA Medical Science & Technology Co., Ltd.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
DS-161
Biological Diagnostics
Biochemistry Analyzer
CE, EEC, MSDS, ISO13485
SINNOWA
Wooden
China
90275000
Product Description
Application:
Biochemistry Analyzer is designed for hospital or clinical laboratory to measure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.

Technical Specifications
ModelDS161
Analytical SystemFully automatic, Random Access
MethodEnd point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc
Assay Item30 assay
Throughput1 Reagent160 tests/hr
2 Reagent100 tests/hr
Test MenuT.BILI         r-GT/GGT    CHO    Ca      APOB-1/B   CHE
D.BILI        ALP/AKP     TG      CL      APOB       CREA
TP           UREA        CK      P       CK-MB      Mg
ALB          CREA        LDH    C        ASO        AFU
Lactic Acid    ALT/GPT      UA    α-HBDH  CO2        FMN
LP(a)         AST/GOT     GLU   AMY      LDL-C      HDL-C
CHE          LA           TBA    ADA      HS-CRP    PA
Fe            Cu           Zn     C3       C4          IgG
IgM           IgA           and drug, toxicity,etc.
Sample Position50
Including standard, control and STAT; either serum cup or primary tube available
Sample Volume1~100ul, 0.1ul/step
Reagent Position36
Reagent VolumeR1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step
Reagent/Sample ProbeWith liquid level sensor, collision sensor, Teflon coating and automatic washing station
Reaction Time0~999 seconds
CuvetteHigh quality uv-transmitted plastic cuvette.
Cuvette Washing5 channels automatic washing system for reaction cuvettes
Probe and Mixer WashingIndependent washing station for each sample/reagent probe and mixer
AlarmAutomatic alarm for malfunction (eg: collision, reagent/sample insufficiency, full waste container, etc)
CalibrationLinear, Non-linear, Multi standard, K factor
Sample Dilution/RetestSample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function
Wavelength340-810nm
Light SourceHalogen lamp
Absorbance Resolution0.0001A
Absorbance Accuracy±0.0003A(0-2.5A)
Repeatability±2%
Quality ControlLevy jennings quality control program at 3 levels
BarcodeOptional
PrinterMultiple report formats available
SystemWindows XP; Windows 7
Power Supply220V or 110V, 50~60Hz
Dimension65×53×52(cm)
Weight45kg


Features:

Random access fully automatic biochemistry analyzer
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection and collision protection for both sample and reagent probe
Reliable cooling system for reagent chamber
Powerful reaction cuvette washing system
barcode scanner (optional)
Lower waste and pro-environment

Structure:
1. Optical System
Light source: Halogen-tungsten lamp, 2000hours working life about
Wavelength: 340nm-810nm
Linear range:0~3ABS
2. Sample System
Sample tray: 50 sample position,available to use serum cup or blood tubeSample volume:1~100ul, programmed by 0.1ul stepSample probe: Liquid level detection and collision protection automaticallyProbe cleaning: automatic washing both inside and outside, Carryover<0.1%Automatic sample dilution
3. Reagent System
Reagent tray: 36 positions for single &dual Reagents.Refrigeration: Refrigerated reagentCompartment 24h Cooling system maintaining temperature 2~8°CReagent volume:1~400ul, programmed by 0.1ul stepReagent probe: Liquid level detection and collision protection automaticallyPre-heating function.Real-time monitoring of reagent volume and auto alarmProbe cleaning: automatic washing both inside and outside, Carry over<0.1%
4. Reaction System
Reaction tray: 60 reaction cuvettes, High quality UV-transmitted plastic cuvettes adoptBack-Dividing-Light technologyMin Reaction volume: 200ulReaction Temperature:37°C+0.1°CMixing system: Independent mixing probeAutomatic washing cuvettes
5. Washing System
Automatic cleaning Sample/mixer probeFive channels washing station for each cuvetteAutomatic record and deduct cuvette blank value
6. Operation Unit
Operation system: Windows XP, WIN 7, WIN 8, or upper
Interface: RS-232
7. Working Conditions
Power Supply: 220V±10%, 50/60HZ; 110V (optional)Power consumption: ≤1200VATemperature:15~30°CHumidity: ≤85%Water consumption: 4L/h