Opgw Optical Fiber Cable 24 48 Cores Outdoor Overhead Power Ground Wire

Price $16.69 Compare
Min Order 2000 Meters
Shipping From Shanghai, China
Popularity 483 people viewed
Quantity
+-
 

Shanghai Gengyun Industrial Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
T-FC055
Communication, Optical Fiber Cable
Optical Cable
Round Wire
100(N/100mm)
<100N
Multicore
CE, ISO9001
Toem OEM
Ss
NA
Carton
Customized
China
Product Description
Fiber optic composite overhead power ground wire (OPGW) is a type of overhead ground wire containing optical fibers, which has multiple functions such as overhead ground wire and optical communication. It is mainly used for communication lines in 110kV, 220kV, 500kV, 750kV, and new overhead high-voltage transmission systems. It can also be used to replace the existing ground wire of old overhead high-voltage transmission systems, add optical communication lines, conduct short-circuit currents, and provide lightning protection. Special structures can be customized according to user needs.
 

Application


1. Communication lines in high-voltage transmission systems;
2. Lighting waveform monitoring system;
3. Overhead power ground wire fiber cable is perfect for an observation system for overhead test line;
4. Maintenance data information system;
5. Opgw optical fiber composite cable is suitable for Power line protection system;
6. Power line operation system;
7. Unmanned substation monitoring.

Product Features


1.Stainless steel tube protects optical fibers with high tensile strength;
2.Small cable diameter, light weight, and low additional load on the tower;
3.The optical unit forms a suitable excess length of primary optical fiber;
4.Slightly poor performance in terms of tensile resistance, torque resistance, and lateral pressure resistance;

 

Characters

 
 AttenuationTape WidthPolarization mode dispersion(PMD)
@850nm@1300nm@1310nm@1550nm@850nm@1300nmSingle FiberLink capacity(M=20,Q=0.01%)
G652D----≤0.35dB/km≤0.21dB/km----≤0.20ps/km≤0.1ps/km
G655------≤0.22dB/km----≤0.20ps/km≤0.1ps/km
50/125μm≤3.0dB/km≤1.0dB/km----≥600MHz.km≥1200MHz.km----
62.5/125μm≤3.5dB/km≤1.0dB/km----≥200MHz.km≥600MHz.km----
 
 TypeMaterialValue
StructureFiber OpticG652D/G655,etc2~48 cores
Protective tubeStainless steel pipe1.5~6mm
Twisted single wireAluminum clad steel/aluminum alloy/aluminum rod1.5~6mm
Maximum diameter18mm
Maximum cross-sectional area200mm2
Mechanical PerformanceMeet Standard DL/T832-2016
Maximum tensile force(RTS)(kN)280
Maximum flattening force(N/100mm)2200
Maximum short-circuit current capacity(40ºC~200ºC)(kA2s)100
Minimum bending radius(dynamic)20D
Minimum bending radius(static)15D
Environmental PerformanceInstallation temperature range (ºC)-10~+50
Operating and storage temperature range(ºC)-40~+65
NO.Technical Parameter
ModelFiber optic cable structure formMaximum number of optical fibers (core)Aluminum clad steel section
(mm2)
Outer diameter

(mm)
Mass per unit length(kg/km)Rated breaking force(kN)20 ºC DC resistance
(Q/km)
Allow short-circuit current capacity
(40-200ºCkA2.s)
1T-FC0526/3.0/20AS,optical unit
1/3.0
24≈409.0≤304≥51≤2.10≥9
2T-FC0536/3.2/20AS,optical unit
1/3.2
24≈509.6≤345≥58≤1.82≥11.5
3T-FC0546/3.8/20AS,optical unit
1/3.8
48≈7011.4≤475≥77≤1.30≥24
4T-FC0556/3.8/40AS,optical unit
1/3.8
48≈7011.4≤340≥42≤0.70≥38
Other fiber cores, fiber types, and strand types can all be designed.
 

Technology Parameters

 
ItemTesting MethodAcceptance criteria
PullGB/T7424.2-E1
Load: Based on changes in fiber optic cable structure
Sample length: not less than 10m;
Link not less than 100m
Duration: 1 minute
40% RTS fiber has no significant strain (0.01%), and the fiber has no significant additional attenuation (0.03dB).
60% RTS fiber strain ≤ 0.25%, fiber additional attenuation ≤ 0.05dB (after tension cancellation, there is no significant residual additional attenuation of the fiber (0.03dB)
FlatteningGB/T7424.2-E3
Load: According to the above table,
Test 3 points for a duration of 10 minutes
After the experiment, the additional attenuation of single-mode fiber at 1550nm wavelength should not exceed 0.05dB/fiber, and there should be no mechanical damage to the OPGW.
Seepage waterGB/T7424.2-F5
Time: 1 hour
Sample length: 0.5m Water height: 1m
No water seepage
Temperature cyclingGB/T7424.2-F1
Sample length: not less than 500m
Temperature range: -40 ºC~+70 ºC
Number of cycles: 2 
Insulation time: not less than 12 hours
After experiment,the additional attenuation of single-mode fiber at 1550nm wavelength should not exceed 0.1dB.
 

Package


Standard disc tools;


What We Have In The Field Of Telecom Optical & Electric Cable :
1>Mature and Efficient Supply Chain System And Rich Industrial Resources
2>Complete Materials Demand Solutions For Cable Manufacturing And Technical Services
3>Overall Solutions And Customized Services In Factory Design, Equipment Configuration, Product Development And Rawmaterial Supply

*Quotation Varies According To Customer's Requirements And Quantity Of Products
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA