Yjv Yjv22 Yjv32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage

Price $30.00 Compare
Min Order 100 Meters
Shipping From Shandong, China
Popularity 386 people viewed
Quantity
+-
 

Shandong New Luxing Cable Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
low voltage cable
Construction, Underground, Industrial, Power Station, Telecommunication
Low and Medium Voltage Cable
DC & AC
PVC
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE, RoHS, VDE
VV, Yjv...
Chang Qing Teng
Low Voltage Cable/ PVC Cable/ XLPE Cable/ Armoured
Single/2/3/4/5/6/7/8/10/16 Core...
3.5/4/6/10/16/25/35/50/70/95/120/150/185/240/300/4
IEC 60502-1, BS 7870-6, BS 6622, BS 7835, GB 5023-
Stranded/Solid/Flexible Copper/Aluminum Conductor
XLPE/PVC/PE/PUR
Electric, House Wire, Building Wire...
Copper Wire Screen(Cws), Aluminium Wire Screen(Aws
Steel Tape Armoured (Sta) or Steel Wire Armoured (
Luxing
Non-Fumigation Wooden Drum, Iron-Wooden Drum.
350x160x270,800x350x550,1000x500x600,1200x500x900.
Shandong
8544492100
Product Description

YJV YJV22 YJV32 VV VV22 VV32 PVC/XLPE/Armoured Cable with Low Voltage 


1.Applications
-These cables are used for electricity supply in low voltage installation system.
-They are suitable for installation in indoors and outdoors,in cable ducts, underground, in power and switching stations,
local energy distributions, industrial plants, where there is no risk of mechanical damage.

IEC60502 PVC Insulated Low Voltage Power Cables

2.Construction
IEC60502 PVC Insulated Low Voltage Power Cables


-Conductors
The conductors shall be either of Class 1 or Class 2 of plain  accordance with IEC 60228.

-Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
-Assembly / Inner Covering
The inner coverings may be extruded or lapped. 
-Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,

 
-Outer Sheath
Outer sheath shall be of extruded PVC  as per IEC 60502-1, Polyethylene, Halogen free compound.
Polychloroprene, chlorosulfonated polyethylene or similar polymers.
-Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

3.Parameters

Single core(unarmoured)IEC60502 PVC Insulated Low Voltage Power Cables
Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
1x42.311.47.1
1x62.811.47.6
1x103.611.48.4
1x164.511.49.3
1x255.61.21.410.8
1x356.71.21.411.9
1x5081.41.413.6
1x709.41.41.415.1
1x95111.61.517.2
1x12012.41.61.518.7
1x15013.81.81.620.6
1x18515.321.722.7
1x24017.52.21.825.4
1x30019.52.41.928.0
1x40022.62.62.031.7
1x50025.22.82.135.0
1x63028.32.82.238.3
 
Two cores(unarmoured)IEC60502 PVC Insulated Low Voltage Power Cables
Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
2x1.51.40.81.89.6
2x2.51.80.81.810.4
2x42.311.812.2
2x62.811.813.2
2x103.611.814.8
2x164.511.816.6
2x255.61.21.819.6
2x356.71.21.821.8
2x5081.41.825.2
2x709.41.41.928.1
2x95111.62.032.4
2x12012.41.62.135.4
2x15013.81.82.239.2
2x18515.322.443.3
2x24017.52.22.548.9
2x30019.52.42.754.0
2x40022.62.62.961.5
 
Three cores(unarmoured)IEC60502 PVC Insulated Low Voltage Power Cables
Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
3x1.51.40.81.810.1
3x2.51.80.81.810.9
3x42.311.812.9
3x62.811.813.9
3x103.611.815.7
3x164.511.817.6
3x255.61.21.820.8
3x356.71.21.823.2
3x5081.41.826.9
3x709.41.41.930.1
3x95111.62.134.7
3x12012.41.62.238.0
3x15013.81.82.342.1
3x18515.322.546.5
3x24017.52.22.752.5
3x30019.52.42.858.0
3x40022.62.63.166.1
 
Three cores+1(unarmoured)IEC60502 PVC Insulated Low Voltage Power Cables
Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2(3)mm(1)mm(3)mm(1)mmmmmm
3x 16/104.53.6111.819.0
3x 25/165.64.51.211.822.6
3x 35/166.74.51.211.825.3
3x 50/258.05.61.41.21.929.6
3x 70/359.46.71.41.22.033.2
3x 95/5011.08.01.61.42.238.4
3x120/7012.49.41.61.42.342.0
3x150/7013.89.41.81.42.546.6
3x185/9515.311.021.62.651.6
3x240/12017.512.42.21.62.958.3
3x300/15019.513.82.41.83.164.5
3x400/18522.615.32.623.373


 
Four cores(unarmored)IEC60502 PVC Insulated Low Voltage Power Cables
Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
4x1.51.40.81.810.8
4x2.51.80.81.811.8
4x42.311.814.0
4x62.811.815.2
4x103.611.817.1
4x164.511.819.3
4x255.61.21.822.9
4x356.71.21.825.6
4x5081.41.929.9
4x709.41.42.033.5
4x95111.62.238.7
4x12012.41.62.342.3
4x15013.81.82.546.9
4x18515.322.651.9
4x24017.52.22.958.6
4x30019.52.43.164.8
4x40022.62.63.373.8


 
Multi-cores(unarmoured)IEC60502 PVC Insulated Low Voltage Power Cables
Nominal Cross SectionDiameter of Conductor (Approx.)Nominal Insulation ThicknessNominal Sheath ThicknessOverall Diameter (Approx.)
mm^2mmmmmmmm
5x1.51.40.81.811.7
7x1.51.40.81.812.6
10x1.51.40.81.815.6
12x1.51.40.81.816.1
14x1.51.40.81.816.8
19x1.51.40.81.818.6
21x1.51.40.81.819.5
24x1.51.40.81.821.6
30x1.51.40.81.822.8
40x1.51.40.81.827.7
48x1.51.40.81.928.2
61x1.51.40.81.930.9
5x2.51.80.81.812.8
7x2.51.80.81.813.8
10x2.51.80.81.817.2
12x2.51.80.81.817.7
14x2.51.80.81.818.6
19x2.51.80.81.820.6
21x2.51.80.81.821.6
24x2.51.80.81.824.0
30x2.51.80.81.825.4
40x2.51.80.82.031.1
48x2.51.80.82.031.7
61x2.51.80.82.134.7


4.Contact us

If you need low voltage cable, medium voltage cable, control cable, rubber cable,
ABC cable, ACSR, underground cable, armoured cable, XLPE cable, PVC cable,

 


IEC60502 PVC Insulated Low Voltage Power Cables

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA