GT-80KW
1 Year/1000 Hours
1 Year/1000 Hours
Trailer Type/Movalble Type
Fixed
Four Stroke
Water Cooling
AC Three Phase
Speed
Land Use
Common Units
Low Noise Automation Type
AC Rotating Exciter
with Cummins Engine
Leroy Somer
Trailer Type(off-Road)
8 Hours Base Fuel Tank
Comap/Smartgen
Installing with ATS
Depends
440V/254V 380V/220V
Gspark
Wooden Package
7CBM
Fujian
8502
Product Description
Brief introduction: Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.
With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.

GT- Series Trailer type Diesel Generators: | ||||||
Model | Rated Power(KW) | Rated Volt(V) | Rated Current(A) | Fre(Hz) | Installed Generator | Wheels No. |
GT-15 | 15 | 400V/230V | 27.2 | 50/60 | Leroy Somer | Two |
GT-20 | 20 | 400V/230V | 36.1 | 50/60 | Leroy Somer | Two |
GT-24 | 24 | 400V/230V | 43.3 | 50/60 | Leroy Somer | Two |
GT-30 | 30 | 400V/230V | 54.1 | 50/60 | Leroy Somer | Two |
GT-40 | 40 | 400V/230V | 72.1 | 50/60 | Leroy Somer | Two |
GT-50 | 50 | 400V/230V | 90.2 | 50/60 | Leroy Somer | Two |
GT-64 | 64 | 400V/230V | 115.8 | 50/60 | Leroy Somer | Four |
GT-75 | 75 | 400V/230V | 135.3 | 50/60 | Leroy Somer | Four |
GT-90 | 90 | 400V/230V | 162.3 | 50/60 | Leroy Somer | Four |
GT-100 | 100 | 400V/230V | 180.4 | 50/60 | Leroy Somer | Four |
GT-120 | 120 | 400V/230V | 216.5 | 50/60 | Leroy Somer | Four |
GT-150 | 150 | 400V/230V | 271 | 50/60 | Leroy Somer | Four |
GT-200 | 200 | 400V/230V | 361 | 50/60 | Leroy Somer | Four |
GT-250 | 250 | 400V/230V | 451 | 50/60 | Leroy Somer | Four |
GT-300 | 300 | 400V/230V | 541 | 50/60 | Leroy Somer | Four |
GT-350 | 350 | 400V/230V | 633.5 | 50/60 | Leroy Somer | Four |
GT-400 | 400 | 400V/230V | 723.2 | 50/60 | Leroy Somer | Four |
GT-500 | 500 | 400V/230V | 815.1 | 50/60 | Leroy Somer | Four |









-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault | |||
When fault occurs during generator set running,could do primary judgement according to following tips. | |||
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light is off. | Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker. |
Cerficates

Welcome your sending inquiry mail or direct contact!