Diesel Generator Set Silent 40 kVA Dg Set Price with UK Perkin Power

Price $5600.00 Compare
Min Order 1 set
Shipping From Fujian, China
Popularity 381 people viewed
Quantity
+-
 

Fuzhou Genspark Equipment Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
GF/GFS-P32KW
1 Year/1200 Hours
1 Year/1200 Hours
Basic Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
AC Rotating Exciter
1104A-44tg2
Leroy Somer or Equivalent
Open Type/Silent Type/Trailer Type/Container Type
8-9 Hous Fuel Tank
Comap/Smartgen/Deepsea
Installing with ATS
Depends
50Hz
400V/230V 3 Phase
Perkins Diesel Generator
Gspark
Wooden Package
4CBM
Fujian
8502
Product Description
Brief introduction:  Genspark Equipment Co.,Ltd mainly Supply Diesel Generator Set and Gas Generator set,including in Famous brands,Deutz,Doosan,MTU,ShangHai Diesel,YangDong etc,raning from 10KW-2000KW Outputs.Having Open type,Silent type,Container type and trailer type generator models.

With more than 10 years experience on supplying Generator sets,We always offer Most Suitable Products for Customers Abroad.












 


 
50Hz Diesel Generator Series Specification 
 
Generator Set PerformanceEngine SpecificationOpen Genset
Genset Model50Hz OutputEngine ModelCylinder NODimensionWeight
50HzPrime StandbyL*W*H (mm)KG
KVAKWKVAKW
GS-P886.597403D-11G31580*810*930359
GS-P2020162318404D-22G41580*810*990460
GS-P30302433261103A-33G31580*810*1150660
GS-P45453650401103A-33TG131580*810*1150722
GS-P60604865521103A-33TG231580*810*1150780
GS-P65655273581104A-44TG141580*810*1165800
GS-P80806488701104A-44TG241760*810*1165840
GS-P10010080110881006TG2A62240*960*1315905
GS-P1351351081481181006TAG62240*960*13151035
GS-P1501501201651321006TAG262240*960*13151100
GS-P1801801441981581106C-E66TAG462345*810*13651300
GS-P2502502002752201306C-E87TAG662430*960*15902270
GS-P3003002403302642306A-E13TAG263280*1130*19503100
GS-P3503502804003202306A-E13TAG263280*1130*19503500
GS-P4004003204503602306A-E13TAG363280*1130*19503800
GS-P4504503605004002506A-E15TAG163310*1180*19503950
GS-P5005004005504402506A-E15TAG263310*1180*19504000
GS-P5505504406255002806A-E18TAG1A63380*1500*21004700
GS-P6256255006905502806A-E18TAG263380*1500*21004800
GS-P8008006408807044006-23TAG3A64450*1750*23504900
GS-P1000100080011008804008TAG2A84850*1870*23507600
GS-P125012501000137511004012-46TWG2A124900*1860*23509150
 
 




























-------------------------------- -----------------------------------------------------After-Sale Part------------------------------------------------------------------------------------
Helpful tips on Generator Set Fault
When fault occurs during generator set running,could do primary judgement according to following tips.
IconIndicator LightReasonFault Analysis and Solve Method
High Water Temperature AlarmHigh Water Temperature AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is caused by lack of Water or Oil Shortage,or Overload. ----Should Automatically Shutdown Generator set Immediately.
Low Oil Pressure AlarmLow Oil Pressure AlarmWhen water Temperature has risen to a level higher than or equal to the sensor setting,the light is on.Normally,it is because of lack of Oil or Lubrication System Failure which caused by refueling or replacing the Oil Filter.----- When occurs this fault,should automatically shutdown generator set immediately.
Low Fuel Level AlarmLow Fuel Level AlarmWhen Fuel level has been detected by sensor fitted to the daily tank,the light is off.Normally,it caused by lacking of Water or Oil Shortage,or Overload.-----When occures this Fault,should automatically shutdown Generator set Immediately.
Battery Charger Fault AlarmBattery Charger Fault AlarmThe Charing System has fault while engine still running,the light is off.Battery Charging System Fault Caused.---The light in on at the initial Start,when the charger reaches a certain speed,the light is off.---This Failure will not lead to Automatic Shutdown Generating Unit.
Crank Failure AlarmCrank Failure AlarmWhen Generator set fail three times(or six times) in arow starting,the light is onIt is caused by Oil Supply System or Re-Start System Failure.
Overload or Breaker Tripping AlarmOverload or Breaker Tripping AlarmWhen Overloading or Short Circuit,the light is on. Tripping Circuit Breaker cause generator set load out.For this fault,it needs to load or unload some parts to eliminate short-Circuit,and then re-close the circuit Breaker.


 