MS400
Physiological Functions of Diagnosis and Monitoring Equipment
Multiparameter Simulator
Middle-aged and Old
Medical Equipment Simulator
12 Month for Main Unit
3.5'' TFT Touch Screen
Rechargeable Lithium Battery
Simulate Four-Channel IBP Data
Simulate Arrhythmia and Pacemaker Waveforms
Simulate Respiration Signal
Simulate Standard ECG Calibration
CONTEC
Carton
18.86 cm(L)*12.50 cm(W)*4.32 cm(H)
China
8543201000
Product Description
Ms400 ECG, Arrhythmia, IBP, Respiration Multi-Parameter Patient ECG Simulator
Model:MS400 Brand:CONTEC
Introduction


MS400 Multiparameter Simulator(ECG simulator) is a portable device, can simulate accurately 12-lead ECG, Respiration, Temperature,2-channel IBP or 4-channel IBP, the default is 4-channel IBP.
Main Features
ECG:
1.Conventional: All leads have the same voltage with the II-lead as the reference
2.Amplitude: 0.5, 1.0, 1.5 and 2.0mV
3.ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
4.ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
5.The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV
Arrhythmia:
1.ATRIAL: Atrial Fib(coarse), Atrial Fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
2.Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
3.Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PAC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, R on T Left Ventricular Focus, Right Ventricular Focus PVC2, Early Right Ventricular Focus PVC2, R on T Right Ventricular Focus, Multifocal PVC
4.Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
Four IBP Channels:
1.The default: 00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Ventricle 25/00
Channel 2: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 3: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 4:
1.Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
2.Man Swan-Ganz: press ENTER key to change every time
3.Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4: P4 tracks the static pressure levels of P3
Respiration:
1.Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
2.Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
3.Baseline impedance: 500, 1000, 1500, 2000Ω
4.Apnea: 12 s, 22 s, 32 s
Temperature:
Four temperature: 0ºC(32°F), 24ºC( 75°F), 37ºC(98.6°F), 40ºC(104°F)
Simulate the signal of square,triangle, pulse and sine with adjustable frequency.
Simulate the pacemaker signal.
Simulate the signal of standard ECG calibration.
Including the ECG waveforms of ANSI/AAMI EC13.
Packaging & Shipping
30*19*10(cm) 1.2 KG
Delevery:within 5-10 working days after payment is confirmed by our company.
Our Services
Warranty: 18-month for main unit,6-month for accessaries
Technical support





Model:MS400 Brand:CONTEC
Introduction


MS400 Multiparameter Simulator(ECG simulator) is a portable device, can simulate accurately 12-lead ECG, Respiration, Temperature,2-channel IBP or 4-channel IBP, the default is 4-channel IBP.
Project | Name | Description | |
1 | IBP1 port | Used to connect IBP1 cable plug. (Refer to "IBP Line Orders") | |
2 | IBP2 port | Used to connect IBP2 cable plug. (Refer to "IBP Line Orders") | |
3 | IBP3 port | Used to connect IBP3 cable plug. (Refer to "IBP Line Orders") | |
4 | IBP4 port | Used to connect IBP4 cable plug. (Refer to "IBP Line Orders") | |
5 | C.O./TEMP port | The port is temperature port at present. Note: if you use this port, plugged the body temperature cables before turned on the simulator. | |
6 | USB port | Reserved port | |
7 | Reset port | Switch the simulator. | |
8 | TF port | Plug SD card. Note: If use the SD card, you need to put the SD card into the simulator before turning it on. | |
9 | Equivalent power jack | According to the instructions of our company's power supply. | |
10 | 10-lead jacks | Output to 10 Universal ECG Jacks, color-coded to AHA and IEC Standards. | |
Label | Meaning | ||
RA or R | Right arm | ||
LA or L | Left arm | ||
RL or N | Right leg(reference or grounded) | ||
LL or F | Left leg | ||
V1, V2, V3, V4, V5 and V6 | V Leads (U.S. and Canada), also referred to as pericardial, precordial or unipolar chest leads. | ||
C1, C2, C3, C4, C5 and C6 | Chest leads (International) | ||
11 | The indicator light of charging | Charge indicator light is red : AC power supply / charging. Green : full electricity. Red and flashing: battery low. | |
12 | Display | The display shows the selected code, the meanings of the code, the waveforms, the list of the functions, System Setting and so on. | |
13 | Keys | There are two kinds of keys: the numeric keys and function keys. | |
0 | View the current settings. | ||
1 | Normal sinus rhythm, 80BPM, 1mV. | ||
2 | Set the ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM. | ||
3 | Set amplitude: 0.5, 1.0, 1.5 and 2.0 mV. | ||
4 | Set the respiratory Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80,100, 120 and 150 R/MIN. | ||
5 | Set the baseline impedance : 500, 1000, 1500 and 2000Ω. | ||
6 | Set the respiratory impedance : 0.2, 0.5, 1.0 and 3.0 Ω. | ||
7 | Channel 1, 2,3 and 4 will be reset to 0. | ||
8 | Set all the channels as IBP waveform. | ||
9 | Set all the channels as static-pressure level. | ||
14 | Control keys | ||
Up and down keys | When select a key which can adjust a setting, you can click the up and down keys to adjust it. | ||
Left and right keys | Switch the pages and browse the codes. | ||
Enter | Determine the choice. | ||
CLEAR | Cancel the current selection, select the code again. | ||
On/Off | Long press the key to turn on or turn off the simulator. |
Main Features
ECG:
1.Conventional: All leads have the same voltage with the II-lead as the reference
2.Amplitude: 0.5, 1.0, 1.5 and 2.0mV
3.ECG Rate: 15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPM
4.ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
5.The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV
Arrhythmia:
1.ATRIAL: Atrial Fib(coarse), Atrial Fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
2.Ventricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
3.Premature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PAC, Left Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, R on T Left Ventricular Focus, Right Ventricular Focus PVC2, Early Right Ventricular Focus PVC2, R on T Right Ventricular Focus, Multifocal PVC
4.Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
Four IBP Channels:
1.The default: 00/00mmHg
Dynamic IBP(unit: mmHg)
Channel 1: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Ventricle 25/00
Channel 2: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 3: Artery 120/80, Radial 120/80, Left Ventricle 120/00, Right Atrium(CVP) 15/10, Right Ventricle 25/00, P-ulmonary Artery 25/10, Pulmonary Wedge 10/2, Left Atrium 14/4
Channel 4:
1.Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
2.Man Swan-Ganz: press ENTER key to change every time
3.Static-Pressure Levels
Channel 1: 0, 80, 160, 240, 320 and 400mmHg
Channel 2: 0, 50, 100, 150, 200 and 250mmHg
Channel 3: 0, 20, 40, 60, 80 and 100mmHg
Channel 4: P4 tracks the static pressure levels of P3
Respiration:
1.Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
2.Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
3.Baseline impedance: 500, 1000, 1500, 2000Ω
4.Apnea: 12 s, 22 s, 32 s
Temperature:
Four temperature: 0ºC(32°F), 24ºC( 75°F), 37ºC(98.6°F), 40ºC(104°F)
Simulate the signal of square,triangle, pulse and sine with adjustable frequency.
Simulate the pacemaker signal.
Simulate the signal of standard ECG calibration.
Including the ECG waveforms of ANSI/AAMI EC13.
Item | Quantity |
Standard components: | |
User Manual (print version) | 1 |
15V adapter or 9V adapter ( USA Porduction) | 1 |
Optional Accessories: | |
Temperature Cable | 1 |
IBP Cable | 1 |
Case Convertion Software and Operating Introduction | 1 |
For more information, please contact your local dealer. |
Packaging & Shipping
30*19*10(cm) 1.2 KG
Delevery:within 5-10 working days after payment is confirmed by our company.
Our Services
Warranty: 18-month for main unit,6-month for accessaries
Technical support