Contec Tlc6000 Handheld Holter Monitor CE Portable 12-Channel ECG Holter

Price $399.00 Compare
Min Order 1 Piece
Shipping From Hebei, China
Popularity 283 people viewed
Quantity
+-
 

Contec Medical Systems Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
TLC6000
Physiological Functions of Diagnosis and Monitoring Equipment
ECG
CE
Middle-aged and Old
Holter ECG
18 Months for Main Unit, 6 Months for Accessory
12
24-Hours
Two "AA" Batteries
About 61.5g(Without Batteries)
CONTEC
Carton
81mm(L) × 60mm(W) × 22mm(H)
Hebei, China
9018110000
Product Description
Contec TLC6000 Handheld Holter Monitor CE FDA Portable 12-Channel ECG Holter
Product Description

12-Channel Dynamic ECG System-TLC6000
Model:TLC6000   Certificate:CE/FDA

Introduction

Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
 
Function
1)Adopt 12-lead system of international standard, continuously record ECG waveform for 24-hour.
2)Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
3)With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
4)Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
5)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function. 
6)Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
7)With analysis functions for 5-minute, 1-hour and whole heart rate variability.
8)One-key print, convenient and fast to print the reports.
9)The death risk in patients with myocardial infarction can be predicted by the "HRT" analysis function.
10)"T-Wave alternation" is an important index to predict the malignant arrhythmia and sudden cardiac death.
11)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
 
Performance
1)Lead: standard 12-lead
2)Power supply: one "AAA" alkaline battery
3)Interface: USB2.0
4)Input impedance: ≥10MΩ
5)CMR: ≥60dB
6)Gain accuracy: At all possible gain settings, the maximum amplitude error of the output is ±10%
7)Gain stability: One minute after energizing the device, the gain change in stable ambient conditions shall not exceed 3% over a 24h period.
8)System noise: ≤50µVp-p
9)Multichannel crosstalk: ≤0.2mV
10)Frequency response: The amplitude response to sinusoidal signals within the frequency range 0.05Hz to 40Hz shall be between the +3dB to -3dB of the response at 5 Hz.
11)Minimum measure signal: 50 µV
12)Timing accuracy: the overall error during 24h shall not exceed 30s.


Physical characteristic

Dimension81mm(L) × 60mm(W) × 22mm(H)
Weightabout 61.5g(without batteries)