CMS8000S
Physiological Functions of Diagnosis and Monitoring Equipment
ECG
CE, FDA
Middle-aged and Old
About 94.6g (Without Battery)
Less Than 50na
Max. 24bits
Max. 1000 Hz
1mv
0.05Hz~150Hz (-3dB~+0.4dB)
CONTEC
Carton
94mm(L) *66mm(W)*31mm(H)
China
90181100
Product Description
CONTEC CMS8000S Stress ECG System Stress ECG Treadmill
2. Observation of the changes of ST segment in real-time, enlargement display of user selected lead, automatic calculation of ST related data.
3. Adopt anti-interference technology to ensure the stabilization of baseline, reduce the effect on ECG waveform from EMG interference, baseline drift and AC interference.
4. Available for both standard and user-defined exercise scheme, automatic instantaneous notice of print and BP measure can be set according to exercise phrase.
5. Operator can mark events during exercise, the ECG waveform of marked event can be compared with current waveform. The event can be observed, edited and printed after excise.
6. Display and print of all kinds of trend chart. Mainly including: HR, BP, METS, HR*BP, exercise trend, ST segment level/influence/slope/3D/J level and ST/HR, etc.
7. Dynamic/static review function after exercise, representation of the whole exercise testing process.
8. Case Import/Export function. Compress the case for storage, which takes up less disk space. The compressed case shall be associated with the file type in operation system. This will make the import operation much more simple and quick.
9. System setting function includes multiple setting items. For example, switching Chinese/English language, format and mode of displaying waveform (12 leads * 1column / 6leads * 1column / 6leads * 2columns / 3leads * 2columns / 3 leads * 1column, etc), color of background, print related setting, filter setting and displaying of optional parameters, etc.
10. Provide multiple functional tools, which are used for device management, cases statistics and other operations.
11. Wireless mode of ECG data sampling, improves the anti-interference capability.
12. Supportive for variety types of exercise equipment
Input impedance: ≥50MΩ
Frequency response: 0.05Hz~150Hz (-3dB~+0.4dB)
Time constant: ≥3.2s
Common mode rejection ratio (CMRR):>60dB, >100dB (filter on)
Calibration voltage: 1mV
Sampling frequency: max. 1000 Hz
Sampling accuracy: max. 24bits
Input loop current: ≤50nA
Polarization resistance voltage: ±500mV
Noise level: ≤15µVp-p
Safety type: internally powered equipment, type BF
Lead cables 1pc
Electrodes 1pc
Grounding wire 1pc
Velcro 2pcs
Serial-port cable 1pc
CD 1pc
Software dog 1pc
Serial-port card 1pc
Introduction
Features
2. Observation of the changes of ST segment in real-time, enlargement display of user selected lead, automatic calculation of ST related data.
3. Adopt anti-interference technology to ensure the stabilization of baseline, reduce the effect on ECG waveform from EMG interference, baseline drift and AC interference.
4. Available for both standard and user-defined exercise scheme, automatic instantaneous notice of print and BP measure can be set according to exercise phrase.
5. Operator can mark events during exercise, the ECG waveform of marked event can be compared with current waveform. The event can be observed, edited and printed after excise.
6. Display and print of all kinds of trend chart. Mainly including: HR, BP, METS, HR*BP, exercise trend, ST segment level/influence/slope/3D/J level and ST/HR, etc.
7. Dynamic/static review function after exercise, representation of the whole exercise testing process.
8. Case Import/Export function. Compress the case for storage, which takes up less disk space. The compressed case shall be associated with the file type in operation system. This will make the import operation much more simple and quick.
9. System setting function includes multiple setting items. For example, switching Chinese/English language, format and mode of displaying waveform (12 leads * 1column / 6leads * 1column / 6leads * 2columns / 3leads * 2columns / 3 leads * 1column, etc), color of background, print related setting, filter setting and displaying of optional parameters, etc.
10. Provide multiple functional tools, which are used for device management, cases statistics and other operations.
11. Wireless mode of ECG data sampling, improves the anti-interference capability.
12. Supportive for variety types of exercise equipment
Performance
Input impedance: ≥50MΩ
Frequency response: 0.05Hz~150Hz (-3dB~+0.4dB)
Time constant: ≥3.2s
Common mode rejection ratio (CMRR):>60dB, >100dB (filter on)
Calibration voltage: 1mV
Sampling frequency: max. 1000 Hz
Sampling accuracy: max. 24bits
Input loop current: ≤50nA
Polarization resistance voltage: ±500mV
Noise level: ≤15µVp-p
Safety type: internally powered equipment, type BF
Accessories
Wireless network card 1pcLead cables 1pc
Electrodes 1pc
Grounding wire 1pc
Velcro 2pcs
Serial-port cable 1pc
CD 1pc
Software dog 1pc
Serial-port card 1pc
Physical Characteristic
Dimension | 94mm(L) *66mm(W)*31mm(H) |
Weight | about 94.6g (without battery) |