Contec Ms100 Hospital Portable Patient Simulator for Blood Oxygen Saturation Measuring

Price $500.00 Compare
Min Order 1 Piece
Shipping From Hebei, China
Popularity 325 people viewed
Quantity
+-
 

Contec Medical Systems Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
Ms100
Physiological Functions of Diagnosis and Monitoring Equipment
Multiparameter Simulator
CE
Middle-aged and Old
Medical Equipment Simulator
12 Month for Main Unit
3.5'' TFT Touch Screen
Rechargeable Lithium Battery
Simulate Four-Channel IBP Data
Simulate Arrhythmia and Pacemaker Waveforms
Simulate Respiration Signal
Simulate Standard ECG Calibration
CONTEC
Carton
27 cm*26.5 cm*13.2 cm
China
8543201000
Product Description

Contec Ms100 Hospital Portable  Patient Simulator for Blood Oxygen Saturation Measuring

Product Description



-NIBP Simulator MS200 is a multi-purpose test instrument for use with oscillometric Non-Invasive Blood Pressure(NIBP) Monitors.

-The appearance is concision,operation is simple and convenient,with its internal pump, the Simulator can generate pressures up to 400 mmHg (53.3 kPa).
-NIBP Simulator provides dynamic blood pressure simulations, static pressure calibration, automated leak testing,and pressure relief valve testing.You can quickly and exact analyse different NIBP Monitors.
 
Main features
1.Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
2.Build-in pump provides pressure source with leak and pressure relief tests
3.NIBP simulations for both arm and wrist cuffs.
4.Provides adult,neonate, eight variations patients conditions,user-defined simulations.
5.Provides arrhythmias,respiratory artifact simulations.
6.65k colors,4.3" LCD display.
7.Built-in air chamber to simulate adult and neonate cuff.


Technical index
Pressure measurement1.Units:mmHg,kPa,cmH2O,inH2O,psi
2.Range:0mmHg-400mmHg
3.Resolution:1 mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1 psi
4.Accuracy:0-300 mmHg:±0.5% of reading ±1 mmHg;
           301-400 mmHg:±2%of reading
Pressure Generator1.Static Pressure Range:50 mmHg-400 mmHg
2.Resolution:1mmHg
3.Difference between target pressure and actual pressure :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc 
Internal leak rate<2 mmHg per minute, with a minimum volume of 300 cc
Pressure Leak TestPressure generate up to 400 mmHg (53.3 kPa) with internal pump.The screen always show the peak pressures and the real-time pressures.Leak rate displayed after 10 seconds. 
Pressure Relief TestPressure generate up to 400 mmHg (53.3 kPa) with internal pump,Displays peak pressure
Standard BP SimulationsPreset blood pressure:
1#: BP: 120/80(93) HR: 80 Pulse Volume: 0.68
2#: BP: 150/100(116) HR: 80 Pulse Volume: 0.65
3#: BP: 200/150(166) HR: 80 Pulse Volume: 0.60
4#: BP: 255/195(215) HR: 80 Pulse Volume: 0.55
5#: BP: 60/30(40) HR: 80 Pulse Volume: 0.75
6#: BP: 80/50(60) HR: 80 Pulse Volume: 0.71
7#: BP: 100/65(76) HR: 80 Pulse Volume: 0.69
Patient Conditions BP Simulations
1.Healthy: BP: 120/80(93) HR:75 Pulse Volume: 0.68
2.Weak Pulse: BP: 110/80(90) HR:95 Pulse Volume: 0.50
3.Mild Exercise: BP: 140/90(106) HR:120 Pulse Volume: 1.00
4.Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume: 1.40
5.Obese: BP: 120/80(93) HR:90 Pulse Volume: 0.50 
6.Geriatric: BP: 150/110(123) HR:95 Pulse Volume: 0.40
7.Tachycardia: BP: 120/105(110) HR:130 Pulse Volume: 0.40
8.Bradycardia: BP: 120/60(80) HR:45 Pulse Volume: 1.10
Arrhythmia SimulationsPremature Atrial Contract 1,Premature Atrial Contract 2,Premature Ventricular Contract,Atrial Fib and PVCs
Respiratory ArtifactsSpontaneous Breathing 1,Spontaneous Breathing 2,Spontaneous Breathing 3,Controlled Ventilation
Neonate simulationsUser can select External or Internal Neonate;
1#: BP: 35/15 HR: 120bpm Pulse Volume: 0.11
2#: BP: 60/30 HR: 120bpm Pulse Volume: 0.10
3#: BP: 80/50 HR: 120bpm Pulse Volume: 0.10
4#: BP: 100/70 HR: 120bpm Pulse Volume: 0.10
Wrist simulations1#: BP:120/80(93) HR: 80bpm Pulse Volume: 0.50
2#: BP:160/100(120) HR: 80bpm Pulse Volume: 0.50
3#: BP:80/55(63) HR: 80bpm Pulse Volume: 0.50
User-Defined simulationsAllows the operator to define blood pressure simulations.
1.Systolic(mmHg) 20-250
2.Diastolic(mmHg) 10-200
3.Heart Rate,(bpm) 30-250
4.Pulse Volume,(cc) 0.1-2.4
Simulant characteristics1.The maximum pulse volume:2.4cc
2.The maximum heart rate:250bpm,200bpm at pulse volume>2.00cc.
3.Internal Adult cuff volume:20cc
4.Internal neonate cuff volume:300cc
5.Blood pressure units: mmHg,kPa
6.Heart Rate Accuracy:±1BPM
7.Patient Conditions:
-Weak pulse, Tachycardia,Obese,Geriatric ±1%±1BPM
-Mild exercise±1.5%±1BPM
-Strenuous exercise±3%±1BPM
Display65k colors 4.3 inch TFT Display, brightness can be changed.
PowerAC100 - 240 V 50/60 Hz, 60 VA
Environmental ConditionsWorking temperature: 15ºC to 40ºC(59ºF to 104ºF)
Storage temperature: -20ºC to +65ºC(-4ºF to +149ºF)
Relative humidity: < 90%,No condensation.
Size (L x W x H)27 cm x 26.5 cm x 13.2 cm
WeightAbout 4kg

Accessories
1.Power cord
2.Fuse
3.User Manual

Certificate
CE

 

Company Profile

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA