Parameter | Precision | Linear Range | Contamination Rate |
WBC | ≤2.0% (3.5-15.0×109)/L | (0-300.0×109)/L | ≤0.5% |
RBC | ≤1.5% (3.0-6.0×1012)/L | (0.10-8.00×1012)/L | ≤0.5% |
HGB | ≤1.5% (100-180) g/L | (0-250) g/L | ≤0.6% |
MCV | ≤1.0% (70-120)fL | - | - |
PLT | ≤4.0% (150-500×109)/L | (0-4000×109)/L | ≤1.0% |


Model | SA-3200 | |||||
Throughput | 60 samples/hour | |||||
Principle | Impedance for WBC differentiation and WBC/RBC/PLT count; Colorimetric method for HGB | |||||
Channels | 2 | |||||
Parameters | 21 parameters(including WBC, Mid#, Lym#, Gran#, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC,RDW-SD, RDW-CV, PLT, MPV,PDW,PCT, P-LCR, P-LCC) | |||||
Histograms | 3 histograms (including WBC, RBC, PLT histograms) | |||||
Sample Volume | Whole blood: 12μl, Prediluted: 20μl | |||||
Calibration | Manual, auto calibration | |||||
Counting Modes | Venous, capilary, prediluted | |||||
Printing Model | Auto print, manual print | |||||
LIS | Support Bi-directional LIS | |||||
Language | Chinese, English, Spanish, French, Russian, Ukrainian | |||||
Reagent | Diluent 10L, Hemolytic agent 250ml, Probe cleanser: 50ml | |||||
Data Input | 9.7-inch touch screen, mouse, keyboard (optional) | |||||
Output | Internal printer, support external printer | |||||
Printer paper | 57*30mm | |||||
Interface | 4 USB ports, network port,RS232 serial port. | |||||
Storage | 100,000 results with histogram | |||||
Unclog | High voltage burn, reverse high-pressure flush | |||||
Work Temperature | 15-30°C | |||||
Power Supply | 100~240 AC, 50/60Hz, 150VA | |||||
Relative Humidity | 30~85% | |||||
Atmospheric Pressure | 70.0kPa-110.0kPa | |||||
Carry-over rate | Parameter | WBC | RBC | HGB | PLT | |
CV | ≤ 1.5% | ≤ 1% | ≤ 1% | ≤ 3% | ||
Background | Parameter | WBC | RBC | HGB | HCT | PLT |
Background | ≤ 0.3×109/L | ≤ 0.03×1012/L | ≤ 1 g/L | ≤ 0.5% | ≤ 10×109/L | |
Linearity | Parameter | Measurement range | CV | |||
WBC | (0.5~10.00×109)/L | (±0.5×109)/L | ||||
RBC | (0.05~1.00×1012)/L (1.01~9.99×1012)/L | (±0.05×1012)/L | ||||
HGB | (2~70g)/L | (±2.0g)/L | ||||
PLT | (10~100×109)/L | (±10.0×109)/L | ||||
Precision | Parameter | Repeatability | Measurement range | |||
WBC | ≤ 6.0% | (3.5~9.5×109)/L | ||||
RBC | ≤ 3.0% | (3.8~5.8×1012)/L | ||||
HGB | ≤ 2.5% | (115~175g)/L | ||||
PLT | ≤ 10.0% | (125-350×109)/L | ||||
HCT | ≤3.0% | 35%~50% | ||||
External Size(W*D*H) | 295*467*418mm | |||||
Packed Size(W*D*H) | Instrument: 404*564*616mm; Reagent: 340*340*340mm | |||||
Net weight | 19 KG | |||||
Gross weight | Instrument: 31KG; Reagent:13Kg |
The production of the Auto Hematology Analyzer machine introduce
1.Start by the blanking process for the metal part
The part was beginning as the blanking
1.Laser blanking machine capacity :8000*2000*10mm
2.We had about 15 pcs of the laser cutting machine in blanking workshop ,name from No1 to No 15,
3.6S fully carry out in our workshop according to the iso13485,
4.All of the raw material can be Traceability

To form the metal part into the shape we need ,the first part was by the bending press and the bending die


1.QTY of the welding robot :23pcs
2.Capacity of the welding robot :500A
3.Work station:2000*1500mm


We had about 10 sets of the plastic injection work for the Lab Horizontal Stacked CO2 Incubator Shaker
1.The capacity for plastic injection machine was :1000*850*750mm
2.The max ton for plastic injection machine was 1000T
1.We need to know how many part in our warehouse
2.We need to anticipate the part when to full fill in for all the benchtop Autoclave with Drying Function Water Storage Tank

9.Electric part assemble to the Multifunction Steam Sterilization Machine workshop,the plc or the other computer control part connect to the machine before move to the next production procss.



Customer review our Laboratory co2 incubator Machine workshop,We were welcome all of our customer to visit our company to review and test the co2 incubator for Organisms, Medical, Chemistry,Our business vision was :long term business ,win-win for the future



From the packing for Laboratory Medical Sterilization Machine to the container loading detail show as below
Warehouse and stroage for the medical Medical Sterilization Machine,the temperature should be control within 18-25° for all equipment and test machine ,all the record can trace within 3 years.


The maintain and repair guarantee for the Medical Sterilization Machine workshop was the key to the business ,when a customer bought a machine from us ,the guarantee was the most importance things customer concern.we sent out technical service team to oversea customer site for the maintain and repair for our customer .Our service for the lab equipment was not stop after the Vacuum Steam Machine Machine sold ,it was the start for our company and your company for win win situation .You use the Vacuum Steam Machine Machine we take care of the rest.



We take part into the MedtecChina Canton Fair (The China Import and Export Fair) exhibition every year ,hope one day we can meet each on the fair
The supplier and the customer was togeher for the future ,both parties should be in win-win situation ,so we were looking forwarder to hold hand by hand for bright future.
Introduction
The Automatic Hematology Analyzer is an in vitro diagnostic device that used for quantitative analysis of blood cells in medical
laboratories, and it can realize three classifications of the count results of white blood cells. This analyzer is a clinical
inspection instrument for screening. When making a clinical judgment based on the analysis results, the doctor should take the
clinical examination results or other test results into consideration. This analyzer is suitable for the detection of white blood
cells, red blood cells, platelets, hemoglobin and other parameters and counting of white blood cells into three classifications.
Function
l Automatic storage of test results, review and print all parameters in test results;
l Color touch screen, all parameters and histograms can be displayed in the same screen;
l Support the expansion of external devices such as mouse, keyboard and printer;
l Optical five reference ranges: newborn, children, adult women, adult men, and general use;
l Multiple clogging elimination methods: high-pressure burning jewel hole, high-pressure reverse rinsing and soaking;
l Automatic cleaning of sample probe;
l By VGA interface, external projector or external display screen can be connected;
l Chinese and English system language;
l Built-in thermal printer, serial port printing and other printing methods;
l With quality control management and calibration management function;
l Use the cyanide-free SFT method (environmentally friendly) to measure hemoglobin;
l Floating boundary algorithm and histogram abnormal prompt function.
Performance
l Test parameters: WBC 3-part differential counting, 23 parameters (including WBC, RBC, PLT color histogram);
l Measurement principle: counting by electrical impedance method, colorimetric method to measure HGB;
l Quality control method: L-J, automatic drawing and printing of quality control charts;
l Sample volume: trace detection, 10μL peripheral blood or anticoagulant blood, pre-dilution mode 20μL;
l Precision: WBC (white blood cell) CV≤4.0%, RBC (red blood cell) CV≤2.0%, HGB (hemoglobin) CV≤2.0%, PLT (platelet) CV≤8.0%, MCV
(average red blood cell volume) CV≤3.0% ;
l Accuracy: the allowable relative deviation range: WBC≤±15%, RBC≤±6.0%, HGB≤±6.0%, PLT≤±20.0%, HCT (hematocrit)≤±9.0%;
l Blank count: WBC≤0.5×109/L, RBC≤0.05×1012/L, HGB≤2.0g/L, PLT≤10.0×109/L;
l Carry-over: WBC≤3.5%, RBC≤2.0%, HGB≤2.0%, PLT≤5.0%;
l Linearity deviation: WBC≤±5%, RBC≤±5%, HGB≤±3%, PLT≤±10%;
l Related coefficient: WBC≥0.990, RBC≥0.990, HGB≥0.990, PLT≥0.990;
l Display: color LCD touch screen;
l Detection channel: dual channel;
l Test speed: 35 (or 60) specimens/hour, continuous working for 24 hours;
l Data storage: It can automatically store more than 30,000 groups of complete results (each result has three histograms);
l Interface: RS232 interface, VGA interface;
l Power supply: ~100V-240V; 50/60Hz.
Accessories
l Mouse
l Thermal print paper
l Power cord
l Grounding cable
l Serial cable
l Pipe assembly (for Diluent, Hemolytic agent,Waste liquid respectively)
l Touch pen
l User manual
l Key of device side board
Physical characteristic
Dimension: 433mm(L)×300mm(W)×430mm(H)
Weight: 19kg
Operating Environment:
Temperature: 18ºC~25ºC
Relative humidity: ≤80%
Atmospheric pressure: 86.0kPa~106.0kPa
Storage Environment:
Temperature: -10ºC~55ºC
Relative humidity: ≤93%
Atmospheric pressure: 50.0kPa~106.0kPa