Profile Certified by SGS/BV
MV90 MV105
Insulated
Solid
Overhead, Heating, Underground
Copper Clad Aluminum
PVC
XLPE
Round Wire
ISO9001, CE, CCC, RoHS, VDE
Huacheng
huacheng
Flexible or Drum Packing
1.5-240 12AWG-1000KCMIL
China
8544492100
Product Description
 
 
 

APPLICATIONS

URD - TRXLPEMLPE insulated cables are designed and manufactured to meet the applications of primary underground distribution suitable for use in wet or dry location, direct burial, underground duct, and exposed to sunlight, To be used at 15kV upto 35kV at conductor temperatures not to exceed 90 deg. C for normal operation.

 

SPECIFICATIONS

TRXLPEMLP insulated URD cables meets or exceeds all applicable requirements of thefollowing standards, and guaranteed all cables manufactured and tested under this standards.

- ANSIIICEA S94-649

- AEIC CS-8

- ASTM B-3, ASTM B-8, ASTM B-230 & ASTM B-231

 

CONSTRUCTION

Conductor : Bare aluminium or copper, stranded class B compressed stranding

Conductor Shield :Extruded semi-conducting compound

Insulation : TRXLP (TreeRetardant XLPE) or XLPE

Insulation Shield : Extruded semi-conducting compound

Concentric Neutral : Uncoated copper concentric neutral wires (coated copper are optional)

Encapsulated Jacket : Non-conducting LLDPE embedded jacket with extruded red stripes.

PVC or Semi-conducting jacket are available upon request

 

MAXIMUM CONDUCTOR TEMPERATURE

Normal continuous at 90 ºC, Overload at 130  ºC and Short circuit at 250   ºC

 

FEATURES & BENEFITS, OPTIONS

- Triple extruded construction by dry curing process guarantees excellent quality of cables

- TRXLPE insulation offers proven superior life span than conventional XLPE cables

- Triplex type is optional, it brings you saving installation cost

- Strand-filled conductor & Water-blocking jacket is available upon request


Data sheet:

Condctor  Copper Neutral  (1/3) diameter(inch)  Weight (Pounds) 
 AWG orMCM  Stranding  Number of 
Wires 
Size AWG 
(Solid) 
 Conductor  Over  Over 
Insul.
 Over Neutral Over ConductorConcentric TotalNo Total WithJacket 
Insulation Shield Wires Encaps. Jkt. Neutral Jacket 
 1/0  19 wire  9  14  0.37  1.12  1.23  1.35  1.46  325.8  119.2  659  4926 
 2/0  19 wire  11  14  0.42  1.17  1.27  1.40  1.50  410.9  146.3  775  808 
 3/0  19 wire  14  14  0.47  1.22  1.32  1.48  1.59  518.1  185.9  900  923 
 4/0  19 wire  11  12  0.53  1.28  1.38  1.54  1.71  653.3  228.0  1110  1055 
 250  37 wire  13  12  0.57  1.33  1.44  1.64  1.81  771.9  282.1  1330  1292 
 350  37 wire  12  10  0.68  1.44  1.54  1.70  1.89  1081  398.0  1633  1519 
 500  37 wire  17  10  0.81  1.57  1.72  1.88  2.04  1544  543.5  2002  1886 
 750  61 wire  25  10  0.99  1.76  1.93  2.11  2.28  2316  801.5  2650  2289 
 1000  61 wire  33  10  1.14  1.92  2.06  2.27  2.43  3088  1058  3847  2960 
 

 