SA1200P
Shiantech
Customized
Portable
CE
CO2
Infrared Absorption Analyzer
Available
Negotiable
0-5000ppm
Available
Available
Shiantech
Carton Box
120*90*33.5mm
Beijing, China
Product Description
Indoor Air quality monitor co2 relay output controller
Brief introduction:
It's an air quality monitor and controller that
1. shows real-time readings of CO2, temperature and humidity
2. shows MIN & MAX readings of above parameters
3. shows a chart with blocks representing values of different parameters in different time scale.
4. (optional) controls start-up and speeds of ventilator to improve air quality and create a healthier, more comfortable and energy-saving living & working environment.
Features:
Application:
Home, office meeting room, school classroom, auditorium, hospital, hotel, library, gym, brewery, laboratory, shopping center, cafe, workshop, warehouse, greenhouse, etc





Production Scene:

Brief introduction:
It's an air quality monitor and controller that
1. shows real-time readings of CO2, temperature and humidity
2. shows MIN & MAX readings of above parameters
3. shows a chart with blocks representing values of different parameters in different time scale.
4. (optional) controls start-up and speeds of ventilator to improve air quality and create a healthier, more comfortable and energy-saving living & working environment.
Features:
- Super large LCD monitors CO2 concentration, temperature, humidity, simultaneously
- Built-in data logger enables data review and analysis of CO2 concentration, temperature and humidity
- Three-level indoor quality indicating system Good, Normal, Poor
- High-end touch buttons
- NDIR sensor for CO2 monitoring
- Audible and visual alarms
- OEM and ODM are welcomed
Application:
Home, office meeting room, school classroom, auditorium, hospital, hotel, library, gym, brewery, laboratory, shopping center, cafe, workshop, warehouse, greenhouse, etc

Measurement | Specifications |
Operating Temperature | 32°F to 122°F (0°C to 50°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Operating & Storage RH | 0-95%, non-condensing |
CO2 Measurement | |
Measurement Range | 0-5000ppm |
Display Resolution | 1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000) |
Accuracy at 0~3000ppm | ±50ppm or ±5% of reading, whichever is greater |
Accuracy over 3000ppm | ±7% of the reading |
Repeatability | 20ppm at 400ppm (standard dev. of 10 readings in 1 minute) |
Temp Dependence | ±0.2% of reading per °C or ±2ppm per °C, whichever is greater, referenced to 25°C |
Response Time | <2min for 63% of step change or <4.6min for 90% step change |
Warm-up Time | <20 sec |
Temp Measurement | |
Operating Temperature | 32°F to 122°F (0°C to 50°C) |
Display Resolution | 0.1°F (0.1°C) |
Response Time | <20min(63%) |
RH Measurement | |
Range | 5-95% |
Accuracy | ±5% |
Resolution | 1% on Main Reading, 0.1% on Max Min Reading |
Power Requirements | 160mA Peak, 40mA average at 5.0V |
Dimension | 120*90*33.5mm (4.7*3.5*1.3 inch) |
Weight | 103g ( 3.6oz) Device only, AC Adapter not included |




Production Scene: