Product Description
DRX-II-PS Thermal Conductivity Measurement Thermal Insulation Tester
Referance standards:ISO22007-2008, ASTM D7984 and GB/T32064-2015 transient planar heat source test method for thermal conductivity and thermal diffusion coefficient of materials.
Main features:
1. Direct measurement of transient thermal transmission, testing time in between seconds 5-160s can be set.
2. Won't influence by the thermal contact resistance like static method.
3. Don't need special sample preparation, only relatively flat sample surface.
4. It can be used on solid, powder, coating, film, liquid and anisotropic materials thermal physical parameter measurement.
5. The structure design of the sample table is clever, easy to operate, suitable for placing samples of different thickness, at the same time, simple and beautiful.





The equipment is mainly based on transient plane heat source technology in testing materials thermal conductivity, thermal resistance and thermal diffusivity by probe. It is widely used in electricity, automobile, material, biology pharmacy and other fields. Provide with multiple probe, software, devices and supporting, can used for testing thermal conduction performance of various types of materials.
Referance standards:ISO22007-2008, ASTM D7984 and GB/T32064-2015 transient planar heat source test method for thermal conductivity and thermal diffusion coefficient of materials.
Main features:
1. Direct measurement of transient thermal transmission, testing time in between seconds 5-160s can be set.
2. Won't influence by the thermal contact resistance like static method.
3. Don't need special sample preparation, only relatively flat sample surface.
4. It can be used on solid, powder, coating, film, liquid and anisotropic materials thermal physical parameter measurement.
5. The structure design of the sample table is clever, easy to operate, suitable for placing samples of different thickness, at the same time, simple and beautiful.
Main technical parameters:
Thermal conductivity | 0.005-300 W/m.K |
Temperature scope | RT ~ 40 °C, resolution: 0.1ºC |
Material type | Metal, alloy, ceramics, ore, composite materials, silicon wafer, polymer, binder, paper, fabric, printed circuit board, propellant... |
Test module | basic, thin film, plate, anistropy, single face, specific heat |
Probe size | 1# Probe Φ7.5mm, and 2# probe Φ15 mm |
Specimen type | Solid, powder, film, coating material, etc. |
Accuracy | 5 % |
Reproducibility | 3% |
Sample thickness | 0.01~5mm |
Data result analysis | Automatic thermal analysis software, Windows 10/7/XP English |
Supply voltage | AC 220V±5%, power: 3.0kw |
Main configurations | DRX-II-PS testing host, probe, testing box, testing software, communication cable. |