Portable Odorous Gas Detector, Doas Measuring Technology, Rapid Detection of Methyl Mercaptan, Methyl Sulfide, So2, No, Co, Tvocs

Price $22900.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 203 people viewed
Quantity
+-
 

Yuanzheng (Jiangsu) Water Science & Technology Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
YZ-POGA-100
12 Months
Yuan Zheng
Customized
Portable
Methanethiol, Dimethyl Sulfide,Methyl Disulfide
Infrared Absorption Analyzer
Spectral Absorption Method
≤ ±3%F.S./24h
≤ ±3%F.S./24h
≤ ±3%F.S.
Hj 212, Modbus-RTU
GPRS/4G
-10ºC~+30ºC
(220±22)VAC, 50/60Hz, 120W
YUAN ZHENG
Carton Box
15 Kg
China
Product Description
YZ-POGA-100 Odorous Gas Analyzer
YZ-POGA-100 Portable Gas Analyzer is developed for detection and warning of accident odor emission, comparative investigation of pollution sources, and rapid detection of ambient air odor gas.  The analyzer is based on ultraviolet differential absorption spectrum (DOAS) technology.

It can detect a variety of odorous gases simultaneously.  And it can be expanded to detect TVOCs, benzene, methylbenzene and other gases according to user needs. Besides, it can also be configured with high-temp heating pipe, and condensation pretreatment system, that can realize the simultaneous monitoring of odor gas and flue gas pollutants.



Features:
  • PLS algorithm, can effectively eliminate the cross interference between the components;
  • Built-in High-quality thermostatic components, small temperature drift, strong environmental adaptability;
  • Equipped with long-life pulse xenon lamp light source, no optical moving parts, high stability
  • Equipped with high-resolution spectrometer, low detection limit, suitable for rapid detection of odorous gases in the ambient air;
  • Equipped with a fast-automatic cleaning module, can perform gas analysis under harsh working conditions without any risk of gas chamber pollution;
  • Optional large capacity mobile power supply, fixed pollution source emission pretreatment system, portable sampling system, and other accessories can be equipped. Achieve rapid detection of organized emissions of odorous gases from fixed pollution sources;
  • Optional automatic sample retention system. Accurate analysis for both laboratory and on-site conditions;

Application:
  • Monitoring of unorganized emission sources from enterprises and chemical parks;
  • Monitoring of odorous gas emissions from urban sewage treatment plants and landfills
  • Rapid analysis of odorous gases from fixed pollution sources;
  • Rapid analysis of odorous gases from unorganized emission sources;
Specification:
 
FactorsMeasuring rangeSolution
methyl mercaptan0~50, 0~5 ppm (ultra-low)100,50 ppb (ultra-low)
methyl sulfide0~50, 0~5 ppm (ultra-low)100,50 ppb (ultra-low)
dimethyl disulfide0~50, 0~5 ppm (ultra-low)100,50 ppb (ultra-low)
hydrogen sulfide0~50, 0~5 ppm (ultra-low)100,50 ppb (ultra-low)
trimethylamine 0~50, 0~5 ppm (ultra-low)100,50 ppb (ultra-low)
carbon disulfide0~10, 0~1 ppm (ultra-low)50,10 ppb (ultra-low)
ammonia0~50, 0~5 ppm (ultra-low)100,50 ppb (ultra-low)
styrene0~10, 0~1 ppm (ultra-low)50,10 ppb (ultra-low)
TVOC0~10, 0~1 ppm (ultra-low)50,10 ppb (ultra-low)
OU0~50000, 0~10000ppm (ultra-low) 5,1 ppb (ultra-low)
Measuring principle:UV-DOAS:  C2H6S, C2H6S2, C3H9N, C6H6, CS2, H2S, NH2, etc;
PID:  TVOCs;
Empirical formula:  Odor/OU;
Zero drift: ±3%F.S./24h
Span drift: ±3%F.S./24h
Linearity error: ±3%F.S.
Communication Interface:GPRS/4G
Digital input:4 inputs, can be configured
Digital output:4 inputs, can be configured
Power supply:(220±22)VAC, 50/60Hz, 120W
Working condition:Temperature: -10ºC~+30ºC,
Humidity:≤90%RH,no condensation