Portable UV Flue Gas Analyzer, Applied in Exhaust Emission Monitoring and Process Control in Power Plant, So2, Nox, Co, CO2, O2 Monitor, High Reliability,

Price $25000.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 449 people viewed
Quantity
+-
 

Yuanzheng (Jiangsu) Water Science & Technology Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
YZ-EM5P
12 Months
Yuan Zheng
Customized
Portable
So2, Nox, Co, CO2, O2.
UV Analyzer
UV-Doas (So2, No, No2), Electrochemis
So2, No, No2 : 0~50~1500mg/M3 O2
≤2%F.S.
≤2%F.S./24hr
≤2%F.S./24hr
(1.5±0.5)L/Min
≤90s (T90)
5~45ºC
Normal Temp Type: 10 Min; Hi
220VAC±22V, 50W or 350W
YUAN ZHENG
Carton Box
12 Kg
China
Product Description
Portable UV Flue Gas Analyzer YZ-EM5P
YZ-EM5P Portable UV Flue Gas Analyzer is mainly composed by monitoring unit of gaseous pollutants (SO2, NOX, CO, CO2), monitoring unit of flue gas parameters (e.g. oxygen content), data collection & processing unit.

The structure consists of flue gas sampler, transmission pipeline, flue gas pre-processor and analyzer.
EM-5P is equipped with easy to use touch screen, large storage capacity, multi-port output and printer for real-time monitoring data.



Feature
  1. Adopt Stoichiometric Algorithm, low detection limit and small temperature drift
  2. NOX content can be directly obtained by measuring NO and NO2 without NO2→NO converter
  3. Full UV spectrum measurement, without cross interference
  4. Electronic scanning of full spectrum, no optical moving parts
  5. Low requirements for measured gas, able to applied in dust and high humidity working condition
 
Application
Applied in exhaust emission monitoring and process control in coal-fired power plant, garbage power plant, cement plant, glass plant, lime factory, ceramics factory, sintering process, coke oven, desulfurization technology, denitration technology, etc.


Specification
Analyzer model:normal temp type: condensation & water removal
high temp type: full-course high temperature
Measurement technology:UV-DOAS (SO2, NO, NO2),
electrochemistry (O2),
nfrared/laser (CO),
infrared/laser TDLAS (CO2)
Range:0~50~1500mg/m3 (SO2, NO, NO2),
0~25% (O2),

0~500~10000ppm (CO),
0~65% (CO2)
Indication error: ≤2%F.S.
Zero drift: ≤±2%F.S./24h
Span drift:≤±2%F.S./24h
Response time:≤90s (T90)
Preheating time: ≤90s (T90)
Power: 220VAC±22V, normal temp type: 50W/high temp type: 350W
Working temperature: 5ºC~45ºC
Working humidity:0~85%RH
Dimension: 498mm×182mm×236mm
Weight:12kg