XHHV535 series
After Sales Service
1 Year
Point Test
Network Cable Tester, HDMI Cable Tester, Audio Cable Tester, Coaxial Cable Tester, Digital Cable Tester
Forming Cable
Shielded
Electricity
CE
Customized
Black
XZH TEST
Wooden Case
China
8543201000
Product Description
High voltage surge generator XHHV535 series
Surge voltage generators enable accurate location of high resistance, low resistance and intermittent faults on high, medium and low voltage cables.Output voltage is continuously adjustable in the ranges 0 - 8 kV , 0-16kV and 0 - 32 kV.
Discharging of high voltage capacitors into the faulty cable can be made continuously or cyclically via surge switch. When the instrument is switched off, the connected cables and the internal surge capacitors are automatically discharged separately from each other.
High surge voltage include three gears, 0-8kV, 0-16kV and 0-32kV.
Three voltage ranges and capacitance switching function
3 range kV-meter direct reading
High surge energy in each voltage range
Automatic discharging device
With zero start protection function, safe and reliable
3 selectable operating programmes: single pulse ,DC , Cycle pulse
Overcurrent protection
Internally installed high-precision test cable fault sampling waveform module
The discharge time can be selected from two modes: timing and manual.
XHHV535-2TS | XHHV535-4TS | XHHV535-6TS | XHHV535-8TS | |
Mains supply | AC220V ±10% | AC220V ±10% | AC220V ±10% | AC220V ±10% |
Option | 110-120V with external auto transformer or isolating transformer | 110-120V with external auto transformer or isolating transformer | 110-120V with external auto transformer or isolating transformer | 110-120V with external auto transformer or isolating transformer |
Mains frequency | 50Hz/60Hz ±2% | 50Hz/60Hz ±2% | 50Hz/60Hz ±2% | 50Hz/60Hz ±2% |
Max. Power consumption(at short circuit) | 2000VA | 2000VA | 3500VA | 3500VA |
Max. output voltage | 32kV | 32kV | 32kV | 32kV |
Output voltage range | 0-8kV 0-16kV 0-35kV | 0-8kV 0-16kV 0-35kV | 0-8kV 0-16kV 0-35kV | 0-8kV 0-16kV 0-35kV |
Max. surge energy | 1225J@each voltage level | 2048J@each voltage level | 3072J@each voltage level | 4096J@each voltage level |
Impulse frequency | default 1 imp./7s,Can be set manually | default 1 imp./7s,Can be set manually | default 1 imp./7s,Can be set manually | default 1 imp./7s,Can be set manually |
Discharge | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device | Unique high-voltage measurement design, in the stop state, it will automatically discharge the internal capacitance of the device |
Burn current(DC output current) | Fault conditioning (burning) with current up to 60 mA @ 32 kV,When the voltage is low, the current will be larger | Fault conditioning (burning) with current up to 60 mA @ 32 kV,When the voltage is low, the current will be larger | Fault conditioning (burning) with current up to 105mA @ 32 kV,When the voltage is low, the current will be larger | Fault conditioning (burning) with current up to 105mA @ 32 kV,When the voltage is low, the current will be larger |
Precision of the KV meter | 1.5 | 1.5 | 1.5 | 1.5 |
operating temperature range | -25~+65ºC | -25~+65ºC | -25~+65ºC | -25~+65ºC |
Over current protection | 9A (greater than 5S) low voltage side | 9A (greater than 5S) low voltage side | 9A (greater than 5S) low voltage side | 9A (greater than 5S) low voltage side |
Over temperature protection | 105ºC | 105ºC | 105ºC | 105ºC |
Safety system | Over-voltage Over-current Overheating protection Automatic discharge after operation | Over-voltage Over-current Overheating protection Automatic discharge after operation | Over-voltage Over-current Overheating protection Automatic discharge after operation | Over-voltage Over-current Overheating protection Automatic discharge after operation |
Protection rating | Not lower than IP54 | Not lower than IP54 | Not lower than IP54 | Not lower than IP54 |
Net weight(kg) | Not more than 130kg | Not more than 130kg | Not more than 140kg | Not more than 150kg |
Delivery includes
Surge wave generator without accessories
Mains connection cable(1pcs-3m)
HV connection cable(1pcs-5m)
Ground line(1set-5m)
Fuse(8A)-3pcs
Discharge rod-(1pcs-50kV)
Option: For extension HV connection cable, ground line, mains connection cable, we can customize lengths of 15m, 20m, 25m, 30m, 50m, etc.
Welcome you contact us for more customization and professional service!~

Manufacturer of underground cable fault detection equipment
Since its inception in 2013, our company has grown to become one of the largest manufacturer of underground cable fault detection equipment in China. An ISO 9001 and CE certified company, we produces a broad range of:
TDR cable fault pre-locators
cable fault pin point locators
cable and pipe locators
high voltage pulse generators
cable identifiers
cable spikers
DC high voltage power supply
cable hi-pot testers
cable fault test vehicles
What we can do
We have the ability to innovate new products and technologies.
We can provide complete system solutions for your project.
We provide online and offline practical and theoretical training.
We provide instrument repair and calibration.

Packaging: Wooden case filled with foam
Shipping: by Air, Sea, Express, etc.
Shipping time: 7-15 days if it's in stock.