ET-PARF800100W
Wireless Repeater
Cable
Standard
Without Lightning Protection
ISO, RoHS
New
5/10/20/40/50/100/200/500 Watts
40- 50dB or Customized
>30/1dB Step or Customized
SMA-50K or Other Customized
1(Max)
50
<5.5A
RS-485 or RS232 or Other Customized
-45dbc
ETENDA
Carton Packing
5/10/20/40/50/100/200/500 watts
Shenzhen
Product Description
800Mhz 900Mhz GSM 4G LTE 45dBc high linearity good IMD3 power amplifier for SDR/repeater/base station
All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freely
Technical Specifications
Monitoring Function Description:
We welcome all OEM orders!




All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freely
Technical Specifications
Frequency(MHz) | 920-960 or Customized |
Input Power(dBm) | ≤10dBm or Customized |
Output Power(dBm) | 50±1(100W ) |
Gain(dB) | 50dB |
IMD3 | -40/45dBc or Customized |
Inband Ripple(dB) | ≤±1 or less |
ALC Range(dB) | ≥25 |
Gain flatness | ≤2dB |
Gain Adjustment range(dB) | 0-31dB(1dB step) |
Input/Output VSWR | ≤1.5:1 |
Impedance(ohm) | 50 |
Voltage(V) | DC+28 |
Working current | 2-4A |
Efficiency | ≥25%-40% or Customized |
Harmonics | ODD≥15dBc;EVEN≥15dBc |
RF In/Out Connector | SMA-Female/N-Female |
Monitor interface | RS-485 or RS232 or other Customized |
Working Temperature | -25~+65 degree |
Storage Temperature | -40 to +85 degree |
Operating Humidity | 0 to 90%, relative |
Weight | ≤1.5KG |
Protection | High temperature,High VSWR or customized |
No. | Monitoring function | Description | |
1 | query | PA ALARM | When an alarm amplifier failure |
2 | SWR ALARM | Amplifier output reflection is too large, VSWR exceeds 3:1, an alarm is generated | |
3 | Over temperature alarm | Module internal temperature exceeds 85 ºC, generates an alarm and turn off the amplifier until the temperature returns to below 65 ºC, re-open the amplifier | |
4 | Over output power alarm | When the output power exceeds the nominal full power 2dB is an alarm | |
5 | Input power detection | Accuracy of ± 1dB | |
6 | Reverse power detection | Accuracy of ± 1dB | |
7 | output power detection | Detecting the actual output power amplifier,Accuracy of ± 1dB | |
8 | Temperature detection | Detection module operating temperature, detection range: -25 ~ +90 ºC, Accuracy of ± 3 ºC | |
10 | SWR | Detecting amplifier output port VSWR range of 1.2 ~ 4.0 | |
11 | query and set | PA attenuator Set and query | Set and query the value of ATT |
12 | PA switching query and set | Query and set the state open tube amplifier |