High Voltage Porcelain SF6 Gas Circuit Breaker LW15-252 LW15B-252 LW15A-550

Price $15000.00 Compare
Min Order 1 Piece
Shipping From Gansu, China
Popularity 258 people viewed
Quantity
+-
 

Gansu A&D Trading Co., Ltd.

VIP   Audited Supplier 15 years
Profile Certified by SGS/BV
LW15
High Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
SF6
Fixed
Porcelain
3
Circuit Breaker
Conventional Circuit Breaker, Overcurrent Protection, OVP(Overvoltage Protection)
CE, CCC
3
Outdoor
40.5kv to 550kv
2000A, 3150A, 4000A, 5000A
XD
Non-Fumigation Wooden Box
Please refer to the attachment
China
8535291000
Product Description
Outdoor High Voltage Porcelain Type SF6 Gas Power Circuit Breaker for Substation.
Product Description
1.General
H.V.A.C.porcelain type SF6 gas circuit breakers, with voltage from 40.5-550kV and rated current up to 4000A, manufac-tured by our company, are provided with three kinds of operating mechanism, pneumatic, spring and hydraulic type. Motor is used in spring mechanism to charge closing spring and charge opening spring at closing. Disk spring is used in hydraulic mechanism to be charged in stead of traditional compressed nitrogen gas for charge, and hydraulic driv ing is used at both opening and closing. Compressed air is used in pneumatic mechanism as driven force for open while spring is used for close. The three kinds of operating mechanisms have their own features and are used in circuit breakers of different voltage class respectively.Due to the unit structure in circuit breaker, there are advantages of mini-mized number of breaks,lower number of parts, simple structure,high reliability and long period of inspection.

LW25-252/T4000-50 circuit breaker with spring operating mechanism was developed and fnished testing in Sep. 2006.
LW25D-126 (145)/T3150-40 (31.5) single-phase operated circuit breaker with spring operating mechanism was developed and fnished testing in Dec. 2006.
LW25A-252/Y4000-50 three-phase mechanically circuit breaker with hydraulic operating mechanism was develped and fnished testing in Jan. 2007.

LW25-126/T4000-40 special circuit breaker for reactive compensation fnished appraisal with swithing back-to-back capacitor bank current of 1600A, switching reactor in series current of 1600A, breaking single capacitor
bank current of 3500-4000A, whinch can meet the requirement of general switchgear and branch switchgear for reactive compensation in UHV.
220kV and above circuit breakers with "XD" brand awarded "China awarded Brand" in Sept . 2007.

2.Normal Service Conditions
2.1 Altitude:≤1000m
2.2 Average relative humidity monthly:≤90%
2.3 Max.wind:≤35m/s
2.4 Pollution class: Third, Class: Fourth class
2.5 Ambient temperature :-35ºC~40ºC
(It's satisfed under the condition of -40ºC in heavy cold area)
2.6 Max.temperature difference daily:25K
2.7 Earthquake intensity:8 degree
2.8 Max.iced thickness:10mm
2.9 Max. radiance from sun:1000W/m2
Note: When product is used under the condition out of above range,
user and manufacturer shall consult to confrm.
Product Parameters
NoLtemUnitLW9-40.5/TLW9-72.5/T  LW9A-72.5/TLW25-126T/145T  LW25D-126T/145T  LW25-252T LW25A-252/YLW15B-252/Y LW15-252/QLW-252/Y
1Rated VoltageKV40.572.5126/145252252252
2Rated FrequencyHz505050505050
3Rated Normal CurrentA3150/40003150/40002000.  3150.  400040003150.  40004000.   5000
4Rated Short-Circuit Breaking CurrentKA5031.5/4031.5/4040.    505063
5Rated Short-Circuit Making CurrentKA12580/10080/100100.   125125160
6Rated Short-Time Withstand Currend And DurationKA50(3s)31.5/(4s)/40(4s)315/(4s)/40(4s)40/(4s)/50(4s)50(4s)63(3s)
7Rated Peak Whithsand CurrentKA12580/10080/100100.   125125160
8Short-Line fault breaking CurrentKAle×90%le×75% 
9Rated Out-Of-Phase BreakingCurrentKAle×25% 
10Creepage Distancecm/KV3.13.12.5.  3.12.5.  3.12.5.  3.1
111Min Power Frequency Withstand VoltageDry TestAcross Open Breaks  To EarthKV95+23.4      95160+42          160230+95             275460+145                                 460                                  520+165/520        460
 Wet TeseAcross Open Breaks  To EarthKV95              95160+42          160230+95               275460+145                              460 460+145    460
12Rated lightning Impulse Whithstand Voltage Across Open Breaks  To EarthKV185+33     185350+59          350650+100           6501050+200                          10501188+226/1188        1188
135Min.Power FrequenceyWithstand Voltage Under Zero -Gauge pressureKV1.3×40.5×31.3×72.5×√31.3×145×√31.3×252×√31.3×252×√3
14Closing Timems150≤150≤150≤110≤11055-80
15Opening Timems≤30≤30≤30≤30≤2514-30
16Breaking  Timems≤60≤60≤60≤60≤50≤50
17Close-Open  Timems40-6040-6040-6050-7040-6040-60
18Operating   Asynchronism     Between  polesOpenms2≤2≤2≤30≤3≤3
Closems≤4
19Rated Reclose Operating Sequence O-0.3s-CO-180s-CO
20Rated Pressure Of  SF6 GasMpa0.50.50 ;0.400.5;0.400.60; 0.400.60.60 
21Alarm/Lock Pressure Of  SF6 GasMpa0.45/0.400.45/0.40; 0.35/0.30.45/0.40; 0.35/0.300.55/0.50;0.35/0.330.55/0.500.55/0.50
22Annual Leakage Of SF6  Gas%≤0.5
23Number Of Breaks Per PolePiece1
24Opening Time Of  MechanisemTimes10000
25Load On teminal In Y-DirectionN7507501250150015001500
26Load On teminal In X-DirectionN500500750100010001000
27Load On teminal In Z-DirectionN7507501000125012501250
28Resistance Of Man Circuit ≤50≤50≤45≤45≤42≤42
29Operating  Mechanism Spring mechanismSpring mechanismSpring mechanismSpring Mechanism Or Hydraulic MechanismHydraulic Mechanism OrPneumatic MechanismHydraulic Mechanism
30Weight Of SF6  Gas Filled For Each CBkg646303030
31Weight Of One Set Of CBkg110011001400/210035004000/45003700
32Applied StandardsGB/T1984,    IEC62271-100,   DL/T402
Detailed Photos


 

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA