YJS560 Compact three phase asynchronous motor 10KV IP54 induction motor

Price $500.00 Compare
Min Order 1 Piece
Shipping From Gansu, China
Popularity 466 people viewed
Quantity
+-
 

Gansu A&D Trading Co., Ltd.

VIP   Audited Supplier 15 years
Profile Certified by SGS/BV
YJS560
Industrial
between 370 and 1500
Three-Phase
Y, Y2 Series Three-Phase
Winding Type
Closed Type
2, 4, 6. 8
Soft Starter
ISO9001, CCC, CE
Lan Dian
One shaft extension
Induction Motor
Cpmpact
compressor, ventilator, water pump, breaker
cutting machine, grinding mill, general machine
LanDian
Naked
220KW-1400KW
China
8501530090
Product Description
General Introduction

YJS Compact three phase asynchronous Cage induction motor 6000V IP54
Application:
YJS series of compact 3 phase case induction motors are suitable to drive compressor, blower, water pump, breaker, metal cutting machine tool, coil grinder & conveying equipment etc., and can also be used as a prime motor in mining industry, mechanical industry, petrochemical industry & other industrial & mining enterprises.
Mounting arrangement:
Horizontal shaft
*Mounting arrangement of the standard motor: IMB3
*For other mounting arrangement on user's requirement, e.g. IMB35
Mounting arrangement of vertical shaft motor, please refer to the catalog for YJSL compact vertical 3 phase case induction motor.
Degree of Protection:
*IP54.
*It can be above IP54 on user's request
Method of cooling:
IC411
Motor with other cooling method can be supplied on user's request.

Main features:
*Compactness in construction, smallness in volume & lightness in weight.
*Be used to take the place of the traditional motor with enclosed cooling method.
*High running efficiency.
*Frame & end cover are cast by precisely casting workmanship with high-grade cast iron (See fig. 03). Good design & excellent machining workmanship make these motors having good heat radiation. The frame & end cover obtain high strength & rigidity. 
*Integrated stator iron-pack is forcedly fitted into the frame with good quality assembly & convenient for maintenance.
*The insulation reliability of windings is improved because they are to be treated by VPI (See fig. 05). 
* The stator core-pack is to be treated with special corona-proof finish, so the motor can run in safety in the high altitude area. 
*The ends of the stator coils are evenly arranged & fixed Reliably (See fig. 02). 
*The cage-rotor of the motor is an aluminum casting part made by special process. Cage-bar, end ring & fan-blade etc. are cast once in a whole, thus its reliability is improved, the permissible rotational inertia of the driven load is increased. the motor can be run under the adverse circumstances with its good electrical performance. 
*Frequency of standard starts are 5,000 times per year. 
*The motor has a high locked-rotor torque, a long time at locked-rotor is permitted;
*All parts of the motor are to be treated with special anti-corrosive process, so it may be run well in the humid tropical region. 
* The motor is designed with a special cooling method to make itself has a ideal cooling result. 
*The terminal box has compact construction, high-grade degree of protection & reliable connection terminals. It can be connected in multi-position.

Service Conditions and Duty
*Altitude not to exceed: 1000m;
*Ambient temperature: -15C~+40C;
*Permissible voltage deviation at running: ±59%
*Rated frequency: 50Hz, permissible deviation: ±19%
*The motor is suitable to drive load with coupling.
*Duty: S1

Capacity family for YJS compact 3 phase case induction motor (IP54, 10KV)
Frame SizeSynchronous Speed (r/min)
300015001000750
Power Output
450220220220220
250250250250
280280280 
315315315 
355355  
400400  
500450450355280
500500400315
560560450355
630630500400
710710560450
800800630 
    
560900900710500
10001000800560
11201120900630
125012501000710
140014001120800
Note: It is not recommended for the specifications between the parentheses, please consult with our sales department on your request.
Product Description

Technical date (des value) for YJS Compact three phase asynchronous Cage induction motor 6000V IP54.

ModelRated Power KWAt full loadIst---InMst--MnMmax--MnMoment of inertia of load Kg.m2Weight Kg
Rated Current  ARated Speed  r/minEfficiency  %Power factor  cos∅
YJS450-222015.8299191.60.8746.560.61.8532.43530
25018299191.80.8726.670.71.8734.43540
28020.1299091.9 0.88 6.890.621.8232.43580
31522.6299192.2 0.87 6.540.681.8434.43600
35525.3298992.2 0.8776.520.61.80 34.43660
40028.3299092.8 0.8786.530.681.8236.53740
YJS500-245031.8298192.8 0.8816.610.611.8444.64040
50035.4297892.80.886.530.61.8340.54060
56039.52981930.8816.640.631.8446.84100
63043.8297993.5 0.8886.490.681.8464.84370
71049.5297693.4 0.8856.50.61.8594390
80055.3297993.8 0.896.740.751.85734540
YJS560-290062.1298694.20.8876.830.641.85955480
100069298594.20.8856.530.61.81855490
112077.2298694.3 0.8876.70.641.841015570
125086.1298694.5 0.8876.950.681.861225590
140096.3298594.60.8876.640.651.841225720
YJS450-422015.5148792.90.886.50.741.831713530
25017.61487930.8826.40.731.821793600
28019.7148793.2 0.88 0.741.821883650
31522148693.3 0.89 6.31.822033770
35524.7148693.5 0.8870.751.822203880
40027.8148693.6 0.8886.50.791.832373950
YJS500-445031.3149193.8 0.8856.080.851.862774210
50034.7149093.80.8876.40.841.862884290
56038.81490940.8860.851.863154360
63043.5149094.0 0.8896.31.853404490
71048.9149094.1 0.8911.853644630
80055149094.2 0.896.20.881.863874720
YJS560-490061.9149094.40.8896.060.911.864195270
100068.8148894.40.8896.20.81.80 4225910
112077.2149094.6 0.8856.170.941.874406060
125085.8149094.7 0.8886.40.931.865106260
140095.9148994.70.896.30.911.846476450
YJS450-622016.2990920.8535.510.821.825343550
25018.398992.20.8565.360.80 1.826123610
28020.498792.0 0.86 4.671.80 6133650
31522.998792.2 0.86 4.641.816723720
YJS500-635525.599193.2 0.864.970.70 1.80 8054240
40028.899193.4 0.8615.061.80 9034330
45032.499293.5 0.865.320.721.8210094380
50035.899293.60.865.590.781.8311094510
56040.399393.80.8565.920.851.8412004660
63045.599393.7 0.8536.30.941.8513004810
YJS560-671049.499394.0 0.8835.80.761.8213205950
80055.799394.1 0.8826.040.811.8413506070
90062.599294.10.8845.270.70 1.8213706140
100069.599394.20.8835.70.761.8215006260
11207899394.3 0.8796.140.841.8515676470
YJS450-822016.974292.10.8145.040.821.8110183780
25019.374292.10.8135.021.8110443820
YJS500-828023.574591.7 0.75 6.420.841.8915374290
31526.174491.9 0.7576.260.831.8816064380
35529.674492.1 0.7516.121.8917654450
40033.474492.2 0.756.051.918394530
45037.274492.40.7555.951.919514670
YJS560-850036.974493.3 0.8386.20.721.8920115630
56041.474493.4 0.8346.230.731.920715700
63046.574493.5 0.8366.150.721.8822025900
71052.874493.80.5296.250.751.923046070
80059.874493.80.8236.331.8924666260
Information on ordering:
The attention should be paid to the type, power, rotation direction, protection degree, cooling mode, special condition and service requirement for fitting machine of motor on ordering.
There are six PT100 resistance thermometers embedded in stator windings of motor, every bearing is with a PT100 resistance thermometer.
One heater is mounted on the frame.
The efficiency, power, max, torque times, torque times of rotor-block, current of rotor-block listed in the table are guaranteed value.
The weight of motor is only for reference. Please see the outline drawing.
The terminal box with the leading-out wire U1, V1, W1 of motor is kept on the right side of the frame viewing from main extension. The terminal box with leading-out neutral wire U2, V2, W2 is kept on the left side of the frame.
Terminal voltage of Y series motor should be not less than 85% rated value in the course of starting. Moment of oforonerty for mechanism to be transported are those machines such as : the water pump and blowing, etc. Meanwhile, when moment of inertia(J) for equipment to be driven doesn't exceed the value in item of listed in the table, it is allowed to start twice continually at actual state (it should be stopped by itself between two starts after switch-off), or to do bot-state start once after rated running. The additional start should be done after one hour' stop of motor.
When moment of inertia of transmission mechanism of Y series motor exceed J(load) value listed in the table or has a requirement of frequently stating, please contact with manufacturer in advance for special order, in order for the reliable running.
The motor is not allowed to bear the external axial force and radial force beside coupling weight on snatt extension. When motor is used as transmission mechanism connected with elastic coupling, the limited device on the shaft be mounted, allowable axial play should be decided by the agreement with the manufacturer.
The other products made by our company are shown as below, the technique agreements should be reached on.
  1. The cpacity and specification of the electric machine xcluding in table.
  2. Other protection type beside IP23, such as IP24, IP44, IP54 etc.
  3. The electric machine with special requirements.
Detailed Photos
 

 

Message Type
* Message Content
* Name  
* Phone
* Email