GE-F60
Yes
10 Years
Active Inverter
Three
>1000W
CE, ROHS, ISO9001
Deye
DC/AC Inverters
Solar Power
Push-pull Type
Sine Wave Inverter
IP55
Deye
Wooden Box
735*1045*2235mm
Ningbo
8504403090
Product Description


Air conditioner | Cooling the BESS. |
Travel switch | When the BESS is detected to be on fire, aerosol is emitted to extinguish the fire. Check whether the BESS's door is closed. |
Smoke detector | A device used to detect smoke in a fire and sound an alarm when smoke is detected. |
Heat detector | A device used to measure temperature and sound an alarm if it detects excessive temperature. |
Fire suppression water pipe | Fire suppression and cooling. |
Aerosol Fire Suppression Device | When the BESS is detected to be on fire, aerosol is emitted to extinguish the fire. |
Manual service disconnect | In order to protect the safety of technicians servicing in high voltage environments or respond to sudden events, the connection of the high voltage circuit can be quickly separated. |
Fan | Emission of combustible gas |
Combustible gas sensor | Detect combustible gases |
Serial relay | Control system |
Terminal line | For connecting cables |
Switching Mode Power Supply | Power source |
Combustible gas sensor | Detect combustible gases |
Miniature circuit breaker | Controlled power-on and power-off |
Water immersion sensor | Check the ESS for water leakage |
Terminal line | Connect external cables |


B- | Connection position of the common negative pole of the battery |
B+ | Connection position of the common positive pole of the battery |
Air switch | Used to manually control the connection between the battery rack and external devices |
Alarm light indicator | Battery system fault alarm indicator |
HV light indicator | High-voltage hazard indicator |
PCS- | Connection position of PCS negative pole |
PCS+ | Connection position of PCS positive pole |
USB | BMS upgrade interface and storage expansion interface |
OUT COM | Connection position with next GE-F-PDU communication output |
IN COM | Connection position with previous GE-F-PDU communication input |
PCS COM | Communication interface with charging and discharging equipment |
START | A start switch of 12VDC power inside the high-voltage control box |
COMM1 | Communicative connection with the cabinet |
COMM2 | Communicative connection with the first battery module; and providing 12VDC power for the first battery module. |
Model | GE-F60 |
Main Parameter | |
Cell Chemistry | LiFePO4 |
Module Energy (kWh) | 5.12 |
Module Nominal Voltage (V) | 51.2 |
Module Capacity (Ah) | 100 |
Battery Module Qty In Series (Optional) | 12 |
System Nominal Voltage (V) | 614.4 |
System Operating Voltage (V) | 480~700 |
System Energy (kWh) | 61.44 |
System Usable Energy (kWh) | 55.29 |
Rated DC Power | 61.44 |
Working Temperature (°C) | Working Temperature (°C) |
Status Indicator | Yellow: Battery High Voltage Power On Red: Battery System Alarm |
Communication Port | CAN2.0/ RS485 |
Humidity | 5%~85%RH |
Altitude | ≤2000m |
IP Rating of Enclosure | IP55 |
Dimension (W/D/H,mm) | 735x1045x2235 |
Weight Approximate (kg) | 1010 |
Installation Location | Rack Mounting |
Recommend Depth of Discharge | 90% |
Cycle Life | 25±2°C,0.5C/0.5C, EOL70%≥6000 |
Warranty | 10 years |
Certification | UN38.3/CB/CE/CEC/IEC62040 |



Q1: How to choose the right inverter?
Q2: How about the delivery time?
A2: Delivery time 7 days for sample; 15 days for bulk order.
Q3: What is the warranty for solar inverters?
A3: Generally warranty for solar inverter is 10 years, also we offer EU warranty.
Q4: How can I get better service from you?
A4: We have professional engineer team can give you best support based on your requirement. If you have any problems during using, we offer 24 hours online service and will solve your problem within 1 hour.