6kw Rack Mounting Load Bank for Data Centre

Price $1000.00 Compare
Min Order 100 Sets
Shipping From Hebei, China
Popularity 357 people viewed
Quantity
+-
 

Hebei Kaixiang Electrical Technology Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
AC240-6KW
12 Months
Universal Testing Machine
>1000KN
0.5
Electronic Load
Dynamic Load
Digital
Manual Control
0-100Kg
AC220V
Under
6kw Rack Mounting Load Bank for Data Centre
Simulating The Server
AC Single Phase 240V 50Hz/60 Hz
Resistive Load: 6kw
1
AC Single Phase 240V 50Hz/60 Hz
About 445 mm*445mm*267mm
Triumph Load
Wooden Case
ISO9001: 2008
Shijiazhuang, Hebei, China
9030390000
Product Description

 6KW Rack Mounting Load Bank for Data Centre

Foreword

(1)This load bank is special designed for data centre, with the feacture of safe,reliable,small size, can complete simulation the site server load, custom made for data centre.

(2)This load bank is a kind of electric power load equipment, which is independent research and development by Kaixiang company.

(3)All the schematic diagram of the provisions of this agreement are for reference only, and ultimately please in kind prevail.

Technical Parameters Sheet

Technical Parameters

Rated voltage/Frequency

AC Single Phase 240V  50Hz/60 Hz

Max Load Power

Resistive Load: 6kW

Load Steps

Total 4 steps A loop: 1.5kW, 5kW. B loop:1.5kW,1.5kW.

Power Factor

1

Load Accuracy  (each step)

±5%

Load Accuracy (overall)

±3%

Fan Power Supply

AC Single Phase 240V 50Hz/60 Hz

Wire Connection

Load Power Supply Input--3 core socket(C19/C13)

Insulation grade

F grade

Duty Cycle

Continuous

Cooling Type

Forced air cooling, horizontal airinlet, horizontal air outlet

Casing Color

Black

Casting Dimension

About 445 mm*445mm*267mm(W*D*H)

Weight

About 18kgs

Operating Environment Parameter

Temperature

-10ºC~+40ºC

Relative Humidity

≤95%

Altitude

≤2500 meters

Atmospheric Pressure

86~106kPa

Brands of Main Components

Load Steps Switch

ABB air switch

 

 Main Functions

(1)Load Testing: Can load any power within the rated value, test the output capacity of the power supply.

(2)Control Mode: This load bank with 4 steps switch, can control load/unloadthrough ABB air switch.

(3)Fan Power Supply: the fan is installed near the air outlet, the fan powered by A loop socket, when use this load bank, preferred to use A loop, after power on A loop power supply, fan will start, then use 4 steps switch combination the load/unload.

(4)Temperature Protection: When temperature exceed the safety threshold, it will send a sound-light alarm. 

(5)Load Cable:Inner cable adopts multicore antiflaming cord and with protection of glass fiber.