2800kw Resistive Load Bank for Generator Testing

Price $70000.00 Compare
Min Order 1 Set
Shipping From Hebei, China
Popularity 454 people viewed
Quantity
+-
 

Hebei Kaixiang Electrical Technology Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
AC400-2800KW
12 Months
Dynamic Load
Digital
Manual Control
400V
Under
400V, 3phase, 50Hz
2800kw
1, 2, 5, 10, 20, 50, 100, 13*200kw
Continuous
Forced Air Cooling
Schneider
Siemens
About 6058*2438*2591mm
Outdoor
Triumph Load
China
9030339000
Product Description

Introduction:

Intelligent AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch power and diesel generator set for electric power, telecom department and manufacturer. It can ensure the reliability of constant power charge that adopts uniformly stepped power input, energy consumption work model and forced air-cooling model. It is of high power density, no red hot phenomenon and automatic protection function overheated. It can't be overheated and broken when the fans stop working. The complete machine can be operated simply and maintain convenient that adopts module design. It can test voltage and current according to client's request, and provide scientific test measures for high-power AC equipment.

 

Main functions of 2800KW 3 phase Resistive Load Bank for Generator

1. Users can set adjustable discharge power according to capability parameter and test request.

2. Voltage and current value can be displayed with multi-functional digital meter.

3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.

4. Two or more Intelligent AC Load Bank can operate in parallel.

5. It can make stable state test, 

6. Remote control by software.

7. Testing data can be saved or  transferred by RS485, data can form curve, to be printed.

 

Function options of 2800KW 3 phase Resistive Load Bank for Generator

Intelligent AC Load Bank have two control patterns: position machine software control and local panel control

Intelligent AC load bank (LED): multi-function digital special meter of 0.5 step can be test and display: AC voltage, current, active power, power factor and frequency. It can communicate with PC via RS485 interface.

Intelligent AC load bank (LCD): Special LCD meter display: AC voltage, current, active power, power factor and voltage frequency. It is of the harmonic analysis function of 1-40 times, and can communicate with PC via RS485 interface.
 

Rating voltage/frequency

400VAC power 2800kW; 3 phase 4 wire, 50Hz, phase voltage 230VAC

 

Max Load Power

Resistive Load: 2800kW

Load Resolution

Resistive Load: 22 steps, 1, 2, 2, 5, 10, 10, 20, 50, 100, 13*200kW

Power Factor

1

Load Tolerance  (each step)

±5%

Load Tolerance(overall)

±3%

Fan Control Power

400VAC 3 phase 4 wire, 50Hz 

Wire Connection

Load bank input--Copper bar (star coupling "Y")

Control power input--Connector-bar

Communication Interface

RS485 or RS232

Insulation

F

Way of Working

Continuous Working

Cooling

Forced air cooling, horizontal inlet air and upwards exhaust cooling

Transportation

Hoisting

Color

RAL7035 or as customer's requirements

Dimensions

About 6058mm*2438mm*2591mm(L×W×H)

Weight

About 7000kg

Pictures of 2800KW 3 phase Resistive Load Bank for Generator






 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA