Profile Certified by SGS/BV
30kw load bank
Forever
12months
500mm
<900kg
Testing Electrical Equipment
>1000KN
0.5
Electronic Load
Static Load
Digital
Computer Control
1000-2000Kg
AC220V
No
Variety
6 U , 430mm*266mm*620mm
5%
Data Center Server Simulator
220V 230V 380V 400V
triumph load
Plywood Cases
30kw
China
90303390
Product Description
Product Description

Liquid Cooling Load Bank 30kw resistive Load Bank for data center testing

Product introduction
Liquid-cooled loads can be used to simulate the actual heat generation and power consumption of real servers in the server room, to test the effect of liquid cooling in the server room and the safety of power consumption in the server room lines, and to provide a data basis and test means for the availability of the server room system.
Liquid-cooled load adopts modularized design scheme, which is easy to maintain and replace, and can be used as a single unit or multiple units in parallel, with multiple gears adjusted for each unit.
Specification sheet

 


Specification
Technical Parameters
Rated voltageAC three-phase, phase voltage 220V/50Hz or DC 240~270V
Rated power30KW (10kW per Section @ AC 220V/50Hz)
Load StepsA single module has 3 independent input ports, each with 10kW.
Load Steps (AC220V/50Hz):
Section A: 1kW, 2kW, 3kW, 4kW;
Section B: 1kW, 2kW, 3kW, 4kW;
Phase C: 1kW, 2kW, 3kW, 4kW;
Note:
1. The three sections of ABC are controlled independently, and each section is divided into different steps. It can be used in either single-phase or three-phase.
2. The heating material is alloy resistor. When DC is 240~270V, the gear power changes according to Ohm's law based on AC220V .
Power Factor1
Heat Exchange Efficiency≥95%
Full Load Tolerance≤±5%
Main Circuit power InterfaceC14 interface, 5 per section, with protective cover.
Load ModeThe panel is equipped with a load switch (small circuit breaker) and manual loading
Control PowerPower supply by the power interface under test
Insulation LevelAC1000V, Insulation Resistance ≥10MΩ
Inlet Water Temperature5-80ºC
Water Circuit Interface1 water inlet pipe and 1 return water pipe, clamp type quick connector, pipe diameter: DN25.
Water outlet with exhaust/water valve (manual). The return pipe is equipped with a flow regulating valve and a filter. The filter is installed at the return pipe outside the module.
PressureThe liquid cooling container or resistor can withstand 1.0MPa working pressure, and the ultimate experimental pressure is 1.5 times the working pressure.
Air TightnessNo leakage for 2 hours under 1Mpa pressure
Water Flow1-10m3/h
Cooling ModeHigh grade pure water cooling
Insulation levelClass F
Protection GradeIP23
Working ModeContinuously working
Pipe MaterialAll pipes are made of stainless steel 304. The containers and pipes are pickled and passivated before delivery to ensure the cleanliness of the water during testing.
Panel Instruction and
Parameter Display
The load panel has a power working indicator light and a fault alarm indicator light.
The inlet and outlet water temperature sensors display temperature, current, voltage, and power data (the display screen has a protective cover), and the sensor accuracy is 0.5.
Parameter Expansion Display
(Extensions)
The equipment reserves 4 sets of 4~20mA signal acquisition modules and input signal access positions, and provides a 24V power supply interface. Users can expand the collection function by adding corresponding collection sensors (such as inlet and outlet water pressure sensors, flow sensors, etc.) Extended acquisition function, the local touch screen design reserves the display and storage functions of the corresponding blocks for users to expand functions.
Installation ProcessThe pipelines adopt reliable connection methods such as flanges and clamps, and the seals meet the requirements of durability and non-pollution of cooling water. The internal pipeline part is insulated and protected. The external interface of the load is equipped with a stainless steel blind plate. When the equipment is idle, the interior can be filled with nitrogen for protection, meeting dust proof and anti-corrosion requirements.
Welding ProcessAll use argon arc welding bottom welding process.
Over Temperature ProtectionThe load brings in and out water temperature monitoring, and alarm prompts when the water temperature is abnormal (inlet and outlet water temperature upper and lower limit alarms, adjustable values, two-stage alarm, one-stage alarm prompt, two-stage alarm for unloading).
Over Current ProtectionWhen switching over-current protection, the audible and visual alarm prompts and cuts off the over-current load;
Pressure protection (extended function)The load can monitor the inlet and outlet water pressure. When the pressure exceeds the set value (the alarm value can be set), an alarm will be given and the load will be cut off.
Ground ProtectionThe load input port has a ground wire connected to the chassis, and the chassis body has a ground terminal for user grounding.
Protection and InterlockWhen one or more AC and DC circuit breakers are over current, in addition to the audible and visual alarm, the load of the over current circuit breaker must be cut off at the same time. It must be manually confirmed to be powered off and reset before it can continue to be used.
It is required that the load cannot be loaded when the coolant is not detected; when the temperature is too high, in addition to the audible and visual alarm, the load must be cut off at the same time, and the power-off reset must be manually confirmed before continued use.
Cabinet Dimension6 U , 430mm*266mm*620mm (W*H*D), excluding the size of the caster.
Cabinet ColorAs per your request
Weight≤35kg
TransportationThere are lifting handles on the side and casters at the bottom for easy transportation;
Load CableThe internal cables are made of multi-core flame-retardant soft wires, protected by fiberglass casings and have waterproof and anti-corrosion capabilities.

Why Choosing Us?

1. Hebei Kaixiang Electrical Technology Co., Ltd is the largest and earliest load bank manufacturer in China, we have 20 years experience. Our factory has 25,000 square meters. We are the leader in domestic market.
2. The sole company that draft the enterprise standard "dry-type load bank".
3. China Power Industry Top Ten Famous Products.
4.  China Power Supply Recommend Products.
5.  Our Intelligent High Power Marine Use Gensets Dry Type Load Bank wins International advanced level by Science and Technology Department of Hebei Province.
6. Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
7.  Certified by SGS.
certificate




Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA