Air Cooler Evaporator for Refrigeration, Ammonia or Freon

Price $3000.00 Compare
Min Order 1 sets
Shipping From Shandong, China
Popularity 239 people viewed
Quantity
+-
 

Yantai Oceanblue Refrigeration Engineering Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
customization
1 Year
12 Months
Stainless Steel&Hot DIP Galvanized
New
Ammonia & Freon
2670*810*990
Stainless Steel Plate & Hop-DIP Galvanizing Plate
1200kg-2500kg
1 Year
Provided
Stainless Steel Coil & Hop-DIP Galvanizing Coil
Counter Flow
Easy to Operate
1525kw
380V/50Hz
1300
Provided
OCEAN|BLUE
Shandong, China
Product Description
Product Description

Product Application  (BAC Evaporative Condenser Coil)

- Whole body of condensing coil with frame are hot-dipped galvanized & Stainless Steel
  (good anti-corrosion and long lifetime).

- Special tube arrangement makes the coil much smarter and get more coil area in a fixed space.

- The tube is oval type (31.75×21.6×1.6mm) which is good for refrigerant flowing inside and good for
  water layer formatting on the tube surface so that to enhance heat-exchange.
 

Main Features  (BAC Evaporative Condenser Coil)

BAC Evaporative Condenser Coil


1.Hot dip galvanized (anti-corrosion and long lifetime)
2.Special tube arrangement ensure a smarter size and high heat-exchange rate.

  All tubes are tested at 2.5MPa air pressure.
3.Special oval tube ensure a better contacting of water on the outer surface of the tube.

 
 
 
 
 
 
Design & Features

OCEANBLUE Evaporative condenser use Oval type heat exchange tube,size 31.7*21.6mm,compare the DN25mm round tube,same length the surface more 10% than Round tube.Also the water contact tube Oval type better than Round type.Can see the bellow pictures.

The cross profile decreased then the velocity of medium in the tube comes faster.
(1) Decrease inner diameter of heat exchange tube wiith more compact tube arrangement can increase 65% of the heat exchange area in the same volume .
(2) Special oval tube ensure a better contacting of water on the outer surface of tubes .also can make the form tighter ,less filling rate of liquid and less air flow resistance.

Working

Condenser coil Working

(1)The coil section rejects heat through the fresh air evaporating ,on the other side is through the sensible heat effect of pre-cooled circulating spray water .
(2)Reducing the coils' evaporative cooling effect is helpful to reduce the possibility of the coils surface scaling

Packing & Delivery
Our Service
 
 
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA