8" Inch Multi-Parameter Patient Monitor

Price $450.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 424 people viewed
Quantity
+-
 

Pocvoda International Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
PV-2000B
Patient Monitor
Patient Monitor
CE, MSDS, ISO13485
All People
POCVODA
Cartoon Box
China
Product Description
Specification:
1. Standard parameters:ECG,RESP,NIBP,SPO2,PR/HR,TEMP.
2.13 types Arrhythmic Analysis, Multi-lead ECG waveforms display in Phase, 15 types Drug calculation and titration table.
3.Anti-ESU, anti-defibrillator; RA-LL impedance.
4.SPO2 can testing for 0.1% weak,high accuracy.
5.Unique breathing measurement technology, real-time monitoring, intelligent filter design, eliminate interference, measuring respiratory accurately.
6.Trend Coexist interface for all parameter to observe easily.
7.OxyCRG Dynamic View display, More intultive with all parameters.
8.Platform scalable with cable or wireless connecting to central monitoring.
9.Brief operation interface, Touchscreen is optional.
10.Up to 2-5 hours working capacity of built-in rechargeable Li-ion battery.
11. 8 inch high resolution color TFT LCD display.
12. Holographic waveform trends playback for 2 weeks and 12 hours off electricity saving.
13.Built-in networking to realize central monitoring function.
  1. Optional: Touchscreen, ETCO2.

15.System start up only need 10 seconds with ARM-A5 Nuclear technology.




Specifications

 
  1. ECG

Lead Mode: 5 Leads or 3 Leads
3 Leads:RA,LA,LL,Lead mode:I,II,III
5 Leads:RA,LA,LL,RL,V,Lead mode:I,II,III,aVR,aVL,aVF,V
Gain  ´250,´500,´1000,´2000

Heart Rate :

Range:          Adult:15 ~ 300bpm ;   Neonate / Pediatric:15 ~ 350 bpm
Accuracy:±1%or ±1bpm,
Resolution:1 bpm
Sensitivity  >200 uV
Differential Input Impedance >5MΩ
Bandwidth
Diagnostic:0.05~130Hz
Monitor:0.5~40Hz
Surgery:1~20Hz


 
  1. RESP

Method: Impedance between R-F(RA-LL)
Scope of base impedance:200~4000Ω
Bandwidth: 0.1~ 2.5 Hz

RESP
Range: Adult:2~120BrPM  Neonate / Pediatric :2~150 BrPM
Resolution:1 BrPM
Accuracy:±2 BrPM
Suffocation warning:10~40s

 
  1. NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring interval in AUTO MODE:1,2,3,4,5,10,15,30,60,90,120,180,240,480 MINS
Measuring interval in STAT MODE 5 MINS
PR range  40~240 bpm
Measuring Range and Resolution
Adult       SYS       40~270mmHg
                  DIA       10~215mmHg
                  MEAN     20~235mmHg
PED      SYS       40~200mmHg
                  DIA       10~150mmHg
                  MEAN           20~165mmHg
            NEO      SYS          40~135mmHg
                        DIA           10~100mmHg
                        MEAN           20~110mmHg
STATIC NIBP range: 0~300mmHg
Static NIBP accuracy:±3mmHg
Max Average tolerance ±5mmHg;Max. Standard tolerance: 8mmHg
Over-pressure protection:
Adult mode:           300 mmHg
Ped mode:       240 mmHg
Neo mode:             150 mmHg


 
  1. SpO2

Measuring range:          0~100%
Resolution:              1%
Accuracy:               70~100%:±2;0%~69%:
Pulse Rate:
Measuring range:    20~300bpm
Resolution:                  1bpm
Accuracy:               ±3bpm


 
  1. TEMP

Channels: 1
Measuring:
Range:    0~50°C
Resolution             0.1°C
Accuracy :   ±0.1°C(sensor tolerance no not included )


6. Power

Adapter
Input:AC 90 V~240V, 50/60Hz
Output:DC 12V-20V
Built-in Battery:
TYPE:14.8V, 2200mAH Li-ion rechargeable battery
Operating time:3.5-4 hours working time under full power
Charging time:2 hours

Accessories list:
Main unit 1set
  1. lead ECG cable 1pc
Adult SPO2 sensor 1pc
NIBP tube 1pc
Adult NIBP cuff 1pc
Surface temperature probe 1pc
AC power 1pc

Optional:
Touch screen