ES-5011ISD
Smoke Alarm
Wired Alarm
Passive
CE, ISO, RoHS, CCC
Indoor
Electro-Optical Type
Cable
Relay Output
Relay Output
Ceiling Mounted
Wired or Wireless Optional
9-24V
Relay Output and Sound & Flash Alarm
>85dB/M
Yes
Ease Security
60PCS/Carton
Suitable to use all over the world
China
8531100000
Product Description
Item Name
High sensitivity Wired Ionization Smoke Detector for Fire alarm
Main Features
12-24V
Anti white light interference, mothproof, dustproof;
Test button;
Alarm Output: RF wireless Signal and Sound & flash alarm& relay output;
Alarm volume: ≥ 85dB/m.
Auto reset ASIC adopted
SMT Design
High stability, strong adaptability for circumstance
High sensitivity
Technical Specification
Operating Voltage: DC 12V to 24V (network type)
9V Battery (independence or wireless type)
Static Current: 200uA ( network type )
10uA (independence or wireless type)
ALARM CURRENT20mA
ALARM INDICATION: RED LED FLASH
SOUND LEVEL: 85dB/m(independence or wireless type)
OPERATING TEMPERATURE: -10 +50º C
OPERATING HUMIDITY: 95RHDETECTING
AREA: 20 square meter
ALARM OUTPUT: Sound & flash alarm (independence type)
RF signal 315MHz or 433MHz (wireless type)
Relay output NO/NC (network type )
RADIO DISTANCE: 100m(open area, wireless type)
SIZE: 107 mm dia. *35mm deep
Installation and Test
1. (independence or wireless type) Taking the battery into battery box before installation.
2. (network type) Connect DC 12V power, red wire for anode, black for cathode, white for COM, orange for NO, yellow for NC.
3. Connect the power, the detector comes into operating state. Indicating LED flashes once per 40 seconds, once per 1 second at alarm state.
4. Select proper place (normally mounted on the center of the ceiling), fix the mounting base, then put the detector into the base and turn it.
5. After installation, press the test button to test the output of the detector. LED should flash once per 1s. The detector should give out sound should send out RF signal (wireless type), should drive relay (network type).
6. You can press the test button to test the detector or blow a little of smoke into the detector to test if it work properly. The detector will recover to normal working state when the smoke disperse.
Ease Security is a Hi-tech enterprise which specializes in anti-theft security alarm products and fire alarm products. Our service range covers R&D, manufacture and marketing. Our current main products are fire alarm panel,home alarm system, outdoor active IR beam detector,PIR detector, smoke detector, gas leakage detector, door magnetic switch, panic button, alarm siren and etc.
High sensitivity Wired Ionization Smoke Detector for Fire alarm
Main Features
12-24V
Anti white light interference, mothproof, dustproof;
Test button;
Alarm Output: RF wireless Signal and Sound & flash alarm& relay output;
Alarm volume: ≥ 85dB/m.
Auto reset ASIC adopted
SMT Design
High stability, strong adaptability for circumstance
High sensitivity
Technical Specification
Operating Voltage: DC 12V to 24V (network type)
9V Battery (independence or wireless type)
Static Current: 200uA ( network type )
10uA (independence or wireless type)
ALARM CURRENT20mA
ALARM INDICATION: RED LED FLASH
SOUND LEVEL: 85dB/m(independence or wireless type)
OPERATING TEMPERATURE: -10 +50º C
OPERATING HUMIDITY: 95RHDETECTING
AREA: 20 square meter
ALARM OUTPUT: Sound & flash alarm (independence type)
RF signal 315MHz or 433MHz (wireless type)
Relay output NO/NC (network type )
RADIO DISTANCE: 100m(open area, wireless type)
SIZE: 107 mm dia. *35mm deep
Installation and Test
1. (independence or wireless type) Taking the battery into battery box before installation.
2. (network type) Connect DC 12V power, red wire for anode, black for cathode, white for COM, orange for NO, yellow for NC.
3. Connect the power, the detector comes into operating state. Indicating LED flashes once per 40 seconds, once per 1 second at alarm state.
4. Select proper place (normally mounted on the center of the ceiling), fix the mounting base, then put the detector into the base and turn it.
5. After installation, press the test button to test the output of the detector. LED should flash once per 1s. The detector should give out sound should send out RF signal (wireless type), should drive relay (network type).
6. You can press the test button to test the detector or blow a little of smoke into the detector to test if it work properly. The detector will recover to normal working state when the smoke disperse.
2 Wire Smoke Detector Connection ![]() 4 Wire Smoke Detector Connection ![]() Installation Base ![]() Side Look ![]() Can WOrk WithFire Alarm Panel ![]() ![]() Product Introduction This product named Photoelectric detector detects the smoke by a couple of infrared diodes. The principle of detecting is granule in the smoke can reflect infrared light. Infrared diodes are placed in the special chamber. The chamber can shield external light, but don't affect the smoke into it. While have no smoke, the diode can receive very weak infrared light. When the smoke entering the chamber, diode can receive more and more light, when the smoke attains the certain density, the detector can give out alarm signal. In order to reduce the interference and lower power consumption, the emitting circuit adopts the pulse signal. The detector adopts the special structure design and ASIC, has the dustproof, mothproof and anti outside light interference feature etc. The detector is suitable for detect the smoke in house, shop, hotel, restaurant, office building, school, bank, library, computer house and storehouse etc.
| ||||||||||||||
Ease Security is a Hi-tech enterprise which specializes in anti-theft security alarm products and fire alarm products. Our service range covers R&D, manufacture and marketing. Our current main products are fire alarm panel,home alarm system, outdoor active IR beam detector,PIR detector, smoke detector, gas leakage detector, door magnetic switch, panic button, alarm siren and etc.
Model | LED Indicator | Power |
ES-5006OSD | 1 | 9-35V |
ES-5007OSD | 2 | 9-35V |
Type | Output | Power |
Independent | Sound & flash alarm | 9V battery |
Network | Relay Output | 9-24V dc |
Wireless | RF signal | 9V battery |