Inscinstech Laboratory Instrument Pilot Scale Fplc Chromatography System Protein Purification System (Unique AutoPure Pilot600)

Price Negotiable Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 495 people viewed
Quantity
+-
 

Inscinstech Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
Unique AutoPure pilot600
1 Year
1 Year
Biochemistry
CE, ISO
Liquid
Liquid Chromatography
Preparative Column
Unique Cdsystem
4-600ml/Min
60kg
Inscinstech
Flight Case
600X500X850mm
Product Description

System performance parameters AutoPure Pilot600 m performance parameter

Main system size L*W*H 600x500x850mm
Main system weight 65kg
Control system Unique CDSystem
Enclosure rating IP54
Electricity supply 100~ 240 V, 50 ~ 60 Hz
Working environment Temperature: 4ºC~35ºC,
Relative Humidity: 20%~95%, no condensation
System pump
(Dual pump system)
A/B pump
Flow rate range: 4~600ml/min
(2- pump packing mode: 1~ 1200ml/min)
Eligibility range: 5%~95%
Pressure range: 0~ 2MPa (20bar, 290 psi)
Viscosity: 0.7~10 cp











UV detector
280nm fixed wavelength detector
LED light source, lifespan>8000h
Detection range: - 6~ +6AU
Linearity: between±2%@0 ~ 2AU
Wavelength Accuracy: ±1nm
Wavelength Repeatability: ±0.1nm
Noise:±2*10 - 5AU
DAD full spectrum direct
reading detector,
200~400nm variable dual wavelength.
Wavelength Accuracy: ±1nm
Wavelength Repeatability: ±1 nm
Noise: ±4*10 - 5AU
(@254nm,1S)

 
Optical fiber conduction, external flow cell, avoid light source temperature
affecting the activity of protein samples, double beam design with high
stability.
Standard flow cell: 2mm optical diameter, 50μl flow cell volume,
maximum pressure resistance 2Mpa
Conductivity detectorDetection range: 0.1mS/cm ~ 999.9mS/cm
Detection cell volume: 20μl
Accuracy: ±3% or 0.2mS/cm
built-in temperature sensor, automatic compensation calibration
Temperature detectorTemperature range: 0 ~99ºC;
Temperature Accuracy:± 2ºC 2ºC ~50ºC
pH detectorDetection range:2~ 12;Accuracy: ±0.15
Inlet options 4 inlets for single pump
A total of 8 inlets of double pumps
Expandable to 12 inlets
Outlets options Maximum 8 outlets
Column valve Single column
Bubble trapEffectively remove air bubbles in flowpath, optional online or offline
MixerMixing chamber volume: 12ml
Bubble sensorSupport up to 3
Pressure sensorOne after each pump(A,B), one before the column, one after the column,
a total of four, detection range is 0- 2MPa