Xmr150 Medical Equipment Price Scan Device 1.5t MRI Scanner Machine for Sale

Price $510000.00 Compare
Min Order 1 Piece
Shipping From Chongqing, China
Popularity 422 people viewed
Quantity
+-
 

Chongqing Vision Star Optical Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
XMR150
Imaging Diagnostic Equipment
X Ray Equipment
CE, ISO13485
Superconductive
1.5t
Active
Active +Passive + Dynamic
≤0.1ppm/H
157cm
600mm
≤2.5mx 2.5mx4.0m
≥4 Years
41mt/M
0.22ms
Visionstar
Wooden
China
Product Description
XMR150 Medical Equipment Price Scan Device 1.5T Mri Scanner Machine for Sale

Feature:

1. Golden-ratio design magnet. A long magnet will make the patient feel depressed during examination while a short magnet will greatly decrease the homogeneity. The"golden-ratio" design magnet is the elegant balance between both.
2. MRI design is inspired by sapphire,which is a transparent armor material for military vehicle. The hardness of sapphire is stronger than any other natural materials except diamond. It is a symbol of the practical performance and sound quality.
3. The smart control screen mounted on the gantry, helps the operator to confirm the table position and patient status in real-time, increases the daily patient flow.
4. Dual side operation panel, the operator can operate the system at both sides of the magnet, saves the positioning time, increases the daily patient flow.
5. With high accuracy diagnosis automatic bed design and intelligent speed control, it has greatly improved patient comfort as well as patient flow.


 
No.ItemSpecification
1Magnet System 
1.1Magnet TypeSuperconductive
1.2Field Strength1.5T
1.3Shielding MethodActive
1.4Shimming Method and TypeActive +Passive + Dynamic
1.5Magnet stability≤0.1ppm/h
1.6Homogeneity (DSV,VRMS) 
1.6.145cm≤0.832ppm
1.6.240cm≤0.323ppm
1.6.330cm≤0.107ppm
1.6.420cm≤0.041ppm
1.6.510cm≤0.01ppm
1.7Length of magnet(exclude cover)157cm
1.8Inner diameter of magnet600mm
1.95 Gauss fringe field(X,Y,Z axis)≤2.5mx 2.5mx4.0m
1.1Total capacity of liquid helium (100% liquid helium800L
full filled ]
1.11Filling liquid helium period≥4 Years
1.12Liquid helium"zero"consumption technologyYes
2Gradient System 
2.1Maximum gradient field (single axis,invalid)41mT/m
2.2Maximum gradient slew rate(single axis, invalid)187mT/m/ms
2.3Minimum gradient rise time0.22ms
2.4Maximum gradient field and slew rate reached atYes
the same time
2.5Gradient cooling systemWater cooling
2.6Full digital real-time transmit and receivingYes
gradient control system
3RF System 
3.1Max RF amplifier power18kW
3.2Center frequency63.87MHz
3.3Real-time digital RF energy monitoringYes
3.4Real-time digital RF short-term accumulationYes
monitoring
3.5Real-time digital RF long-term accumulationYes
monitoring
3.6Parallel working RF receiver channels8/16
3.7Parallel working RF A/D converters8/16
3.8Each coil unit has corresponding pre-amplifierYes
3.9Parallel acquisition technology platformYes
3.1Maximum bandwidth of each parallel≥1.0MHz
acquisition receive channels
3.11Transmission bandwidth550kHz
3.12Maximum receiver signal resolution≥16bit
3.13Fully digital RF systemYes
3.14RF receiving amplifier noise level≤0.45dB
3.15Multi-channel phased array receiver coil 
3.15.1Head coilAvailable
3.15.2Neck coilAvailable
3.15.3Body coilAvailable
3.15.4Knee coilAvailable
3.15.5Shoulder coilAvailable
3.15.6Ankle coilAvailable
3.15.7Wrist coilAvailable
3.15.8Breast coilAvailable
 Remark The coil configuration is subject to the 
final contract
4Scan environment 
4.1Patient table driven modeMotor-driven
4.2Position accuracy≤0.5mm
4.3Table length2400mm
4.4Horizontal movement range2055mm
4.5Horizontal motion maximum speed≥200mm/s
4.6Patient table lowest height675mm
4.7Maximum patient weight200kg
4.8Feet-first entry modeYes
4.9Table can be controlled by machine cover in case ofYes
emergency
4.1Table control system on both side of rackYes
4.11Lighting, ventilation, call systemBe able to adjust
5Computer system 
5.1MRI softwareBASDA
5.2System softwareWINDOWS7
5.3CPU≥3.1GHz
5.4Main memory≥4GB
5.5Hard disk≥500GB
5.6Color LCD monitor24"
5.7Monitor resolution1920×1200
5.8External storageDVD/USB
5.9DICOM3.0Yes
6Scanning parameter 
6.1Spin-echo sequenceYes
6.1.1SE 2D/3DYes
6.1.2FSE 2D/3DYes
6.1.3FSE sharingYes
6.1.4Single shot FSEYes
6.1.5Spin echo fat-suppression imagingYes
6.1.6Spin echo frequency fat suppression imagingYes
6.1.7Spin echo water suppression imagingYes
6.2GRE 2D/3DYes
6.3DWIYes
6.3.1Max.b value10000
6.4IR sequenceYes
6.4.1IRYes
6.4.2FIR(water /fat suppression)Yes
6.4.3FLAIRYes
6.4.4STIRYes
6.4.5Water-fat SeparationYes
6.5.1Pre-saturationYes
6.6GatingYes
6.7Accelerated sequenceYes
6.8Anti-movement scanning technologyYes
6.9Min.2D thickness0.1mm
6.1Min.3D thickness0.05mm
6.11Max.FOV50cm
7.6.5Applied direction of parallel acquisition factorX,Y,Z
7.7Artifact correction technologyYes
7.7.1Fluid compensationYes
7.7.2Respiratory compensationYes
7.7.3Head motion artifact correctionYes
7.7.4Elimination of magnetic sensitive artifactYes
7.7.5Eddy current adaptive correctionYes
7.7.6Gradient linearity correctionYes
7.7.7Multi-echo phase correctionYes
7.8Rapid automatic correction technologyYes
7.9Automatic frequency tracking technologyYes
7.1Automatic coil recognition technologyYes
7.11Automatic phase correction technologyYes
7.12Echo navigation technologyYes
7.13RF balance drive technologyYes
7.14RF de-phase technologyYes
7.15Gradient de-phase technologyYes
7.16Section scanning technologyYes



Our Factory