100W 700 MHz to 2700MHz GaN High Power RF Amplifier/RF Module/Broadband RF Power Amplifier

Price Negotiable Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 473 people viewed
Quantity
+-
 

Shenzhen Etenda Technology Limited

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
ET-PAU100W
RF Power Amplifier
Wireless
Transmitting RF Power
Without Lightning Protection
ISO, RoHS
New
5/10/20/40/50/100/200/500 Watts
40- 50dB or Customized
>30/1dB Step or Customized
SMA-50k or Other Customized
1(Max)
50
<5.5A
RS-485 or RS232 or Other Customized
ETENDA
Carton Packing
5/10/20/40/50/100/200/500 watts
Shenzhen
Product Description
100W 700 MHz to 2700mhz GaN High Power RF Amplifier/RF Module/Broadband RF Power Amplifier       
All the parameters of PA can be customized depend on your request, if you have any customized parameters pls contact us freely

Technical Specifications
 
Frequency(MHz)700-2700M
Input Power≤20dBm
Output Power(dBm)50±1(100W )
ALC Range(dB)≥25
In-Band ripple(dB)≤2
Gain(dB)45 or Customized
Gain Adjustment range(dB)>31/1dB step or Customized
Gain Adjustment Linearity(dB)≤±1
Gain Flatness(dB)±0.5(Max)
Impedance(ohm)50
VSWR≤1.4:1
Voltage(V)DC+28
Power current≤8A
RF ConnectorSMA-50K or other Customized
Monitor interfaceRS-485 or RS232 or other Customized
Monitoring communication protocolsUse Manufacturers protocol or Customized
Working Temperature-40~+65 degree
Storage Temperature-55 to +85 degree
Operating Humidity0 to 90%, relative
Surface ColorMetal color conductive oxide and other color customized
weight 2.5KG
RemarkModule with output short circuit or open circuit protection


Monitoring Function Description:
No.Monitoring functionDescription
1query PA ALARMWhen an alarm amplifier failure
2SWR ALARMAmplifier output reflection is too large, VSWR exceeds 3:1, an alarm is generated
3Over temperature alarmModule internal temperature exceeds 85 ºC, generates an alarm and turn off the amplifier until the temperature returns to below 65 ºC, re-open the amplifier
4Over  output power alarmWhen the output power exceeds the nominal full power 2dB is an alarm
5Input power detectionAccuracy of ± 1dB
6Reverse power detectionAccuracy of ± 1dB
7output power detectionDetecting the actual output power amplifier,Accuracy of ± 1dB
8Temperature detectionDetection module operating temperature, detection range: -25 ~ +90 ºC, Accuracy of ± 3 ºC
10SWRDetecting amplifier output port VSWR range of 1.2 ~ 4.0
11query and setPA attenuator Set and querySet and query the value of ATT
12PA switching query and setQuery and set the state open tube amplifier
 
 
 

Message Type