SX-150
Provided
1 Year
<500mm
<900kg
Cetane Octane Tester
<1000KN
0.5
Electronic Load
Static Load
Digital
Auto Control
850g
5.4V
No Need
Testing Octane and Cetane of Gasoline and Diesel
40 ~ 135 on
50-2400 Min.
20 ~ 100
0 ~ 95%
1 ~ 5 Seconds
Widely Used in Petrol Station, Lab, Oil, Eletrical
LCD Liquid Crystal Display
Portable Type with Battery
CE, ISO
More Than 6 Years
7 Days
FUOOTECH
in Standard Exportation Case
100*210*40mm
China
9025800090
Product Description
SX-150 Portable Octane and Cetane Analyzer
New oil products grade SX-150 analyzer is manufactured on the basis of advanced high precision microprocessor. the instrument can be used together with a PC a laptop through USB interface. Analyzer uses automatic computer-based calibration, saving measured data in the instrument memory with analysis date and time followed by their transfer to the PC (in Microsoft Excel or txt format).
The instrument has easy of control attrition and aggressive environments resistive 8-key antiglare keyboard (made in Germany). When determining petrol breakdown time, the petrol brand is selected in the instrument. The instrument switches to corresponding operating mode. Oxidative stability determination complies with GOST 4039-88 (ASTM D 525). Portable octane analyzers are often used for on-site analysis of octane number of power gasoline, corresponding to the motor method and research method (RON and MON), and also suitable for cetane number analysis of diesel.
In addition, the temperature of the analyzed liquid and the freezing point of diesel can also be measured, and the measurement results are displayed on the LCD liquid crystal display.
This octane analyzer is widely used all over the world. Its measurement method conforms to international standards: octane measurement conforms to: ASTM D 2699-86, ASTM D 2700-86. Diesel cetane measurement conforms to: ASTM D 4737- 03, ASTM D 613, EN ISO 5165.
Item | Unit | Value |
Gasoline octane number range | ON | 40-135 |
Gasoline octane number measurement accuracy | ON | ± 0.5 |
Limit of acceptable difference between parallel octane number measurements, max | ON | ± 0.2 |
Gasoline stability measurement range Petrol oxidation breakdown time measurement range | min. | 50-2400 |
Acceptable limit of gasoline oxidation breakdown time basic error | % | 5 |
Acceptable basic error limit of petrol oxidation breakdown time | min. | 10 |
Cetane number measurement range | CN | 20-100 |
Measurement accuracy of diesel cetane number | CN | ±1.0 |
Acceptable difference limit between cetane numbers parallel measurements, max | CN | ±0.5 |
Acceptable error limit when determining diesel fuel pour point | Co | ± 5 |
Kerosene content determination range in diesel fuels | % | 0-95 |
Acceptable basic error limit when determining kerosene content in diesel fuels | % | 3 |
Measure time | sec. | 1-5 |
Minimum power supply for instrument operation | V | 5.4 |
Instrument service life | MIN. years | 6 |
Overall dimensions of: | ||
Electronic unit | mm | 100х210х40 |
Sensor | mm | 60х100 |
Instrument weight (including 1 sensor) | g | 850 |