250bar (25MPa) CH4 Methane Natural Gas Booster Compressor for CNG Filling Station

Price $5000000.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 267 people viewed
Quantity
+-
 

Shanghai Sunshine Industry Technology Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
SSI
12 Month
12 Month
Lubricated
Air Cooling
Duplex Arrangement
Horizontal
Closed Type
Multistage
Gas
380V
New
Computerized, Customization
Customization
Yes
Customizing
sunshine
Standard Packing
steel
China
841480
Product Description
Company Profile

 

The company's main products include desulfurization, dehydrocarbons, separation, compression, filling, storage and transportation equipment for natural gas extraction in oil and gas fields; complete sets of wellhead gas recovery equipment; complete sets of vented natural gas recovery equipment; complete sets of coalbed methane, shale gas and biogas development and utilization equipment Equipment; CNG filling station complete equipment; LNG complete equipment; BOG compressor; large-displacement screw-piston compound compressor; membrane nitrogen and adsorption nitrogen production complete equipment; in addition, hydrogen, oxygen, nitrogen, argon, carbon monoxide gas, carbon dioxide gas, coal gas, hydrogen sulfide gas, propylene gas, ethylene gas, methyl chloride gas, trifluoropropane gas, liquefied petroleum gas and other special gases, low-temperature gases and air compressors. Among them, the W and V series non-lubricated compressors produced by introducing advanced foreign technology have reached the international advanced level.

 
Product Description

The company currently has ten series of leading products and hundreds of specifications. Its volumetric flow rate: 0.05~200m3/min. Pressure range: low pressure type 0~1.6MPa, medium pressure
Type 1.6~8.0MPa, high pressure type 8.0~50.0MPa. Lubrication methods are divided into three types: oil, oil-free and completely oil-free. The structural types include Z, W, V, D, M and H types. There are three cooling methods: air cooling, water cooling, and mixed cooling. In addition to providing users with customized products, we can also carry out personalized design and manufacturing according to user needs.
CNG STANDARD STATION COMPRESSOR
CNG standard stations are built where natural gas pipelines pass through.
Gas is taken directly from the natural gas pipeline. Natural gas undergoes desulfurization, pressure regulation, metering, and
Filtration, dehydration and other processes enter the compressor unit, and then compress, cool and purify
Then the pressure is increased to 25Mpa, and finally the high-pressure trailer is supplied to the high-pressure trailer through the air filling column.
Fill up the gas, and also fill up the car through the gas vending machine. Our company can provide overall
Solutions and turnkey projects.
Equipment composition: air inlet filter pressure regulating metering device, desulfurization tower, low-pressure dehydration device, piston compressor, sequence control panel, gas storage bottle group, adding
Gas machines, gas filling columns, CNG trailers, gas alarm devices and other equipment.
Covered area: about 2000~4000m²
Optimal transportation radius: 150km
Suitable scale: ≥40000Nm²/d
Equipment installation time: about 30 days.

 

NO.TYPEIntake pressure
MPa
CAPACITY
Nm3/h
MOTOR
KW
COOLING WEIGHT(TONS)SIZE
mm
1W-5.6/0.5-2500.05500160WATER COOLING95000×2300×2200
2W-3.6/1-2500.1435110WATER/MIX COOLING62400×2220×2150
3W-4.75/1-2500.1570132WATER/MIX COOLING62400×2220×2150
4W-7.5/1-2500.1900270WATER/MIX COOLING178500×2260×2200
5W-4.5/1.4-2500.14650160WATER/MIX COOLING73820×2270×2150
6W-4.7/2-2500.2850185WATER/MIX COOLING73820×2270×2150
7WF-3.6/(1.5~2.5)-250  0.15~0.250.15~0.25540~750160AIR COOLING146200×2190×2080
8W-3.6/(1.5~3)-2500.15~0.3540~860185WATER/MIX COOLING74000×2270×2150
9V-3.2/(3-5)-2500.3~0.5760-1150220AIR COOLING146300×2525×2500
10VF-3.2/(3~5)-2500.3~0.5770~1150220WATER/MIX COOLING146300×2500×2500
11W-1.5/8-2500.8810132WATER/MIX COOLING84000×2300×2000
12VF-2/(10~16)-2501.0~1.61320~2000280AIR COOLING105600×2500×2300
13D-5/(2~4)-2500.2~0.4900~1500315WATER/AIR/MIX COOLING235000×3500×2500
14D-4.2/(3~6)-2500.3~0.61000-1760280WATER/AIR/MIX COOLING235000×3500×2500
15D-3.6/(4~7)-2500.4~0.71050~1730315WATER/AIR/MIX COOLING235000×3500×2500
16D-2.6/(7~12)-2500.7~1.21250~2000280WATER/AIR/MIX COOLING205000×3500×2500
17VF-0.76/(7~13)-2500.7~1.3365~640100WATER/AIR/MIX COOLING86000×2200×2230

CNG MOTHER STATION COMPRESSOR
The CNG mother station is built in a place where natural gas pipelines pass through.
Take the gas directly from the gas pipeline. Natural gas undergoes desulfurization, pressure regulation, metering, filtration,
Dehydration and other processes enter the compressor unit, and then are compressed, cooled and purified to make it
The pressure is increased to 25Mpa, and finally the high-pressure trailer is filled with air through the air filling column.
Sometimes, cars can also be refueled through gas vending machines. Our company provides turnkey projects.
Equipment composition: air inlet filter pressure regulating metering device, desulfurization tower, low pressure desulfurization tower
Water device, piston compressor, sequence control panel, gas storage bottle group, gas filling
machine, gas filling column, CNG trailer, gas alarm device and other equipment.
Covered area: about 2000~4000m²
Optimal transportation radius: 150km
Suitable scale: ≥40000Nm²/d
Equipment installation time: about 30 days.
NO.TYPEIntake pressure
MPa
CAPACITY
Nm3/h
MOTOR
KW
COOLING WEIGHT(TONS)SIZE
mm
1  D-5/(2-4)-2500.2~0.4900~1500315WATER/AIR/MIX COOLING235000×3500×2500
2  VF-3.2/(3~5)-2500.3~0.5770~1150220AIR COOLING146300×2500×2500
3  D-4.2/(3-6)-25003~0.61000-1760280WATER/AIR/MIX COOLING235000×3500×2500
4  D-3.6/(4~7)-2500.4~0.71050~1730315WATER/AIR/MIX COOLING235000×3500×2500
5  D-2.6/(7~12)-2500.7~1.21250~2000280WATER/MIX COOLING205000×3500×2500
6  VF-0.76/(7~13)-2500.7~0.3365~640100MIX COOLING86000×2200×2230
7  D-2.8/(8-12)-2500.8~1.21350-2150280WATER/AIR/MIX COOLING235000×3500×2500
8  V-2/(9-14)-2500.9~1.41200-1800280WATER/AIR/MIX COOLING126500×2525×2300
9  VFD-2/14-2101.41800280AIR COOLING1510000×4000×3000
10  D-2.5/(12-14)-2501.2~1.41950-225018WATER/AIR/MIX COOLING235000×3500×2500
11  VF-2/(10~16)-2501.0~1.61320~2000280AIR COOLING105600×2500×2300
12  D-2.8/(10~16)-2501.0~1.61800-2850355WATER/AIR/MIX COOLING235000×3500×2500
13  V-1.43/(16~20)-2501.6~2.01460~1800220WATER/AIR/MIX COOLING116000×2500×2250
14  D-2.4/(16-20)-2501.6~2.02450-3000355WATER/AIR/MIX COOLING235000×3500×2500
15  D-2.4/(16-23)-2101.6~2.32450-3450355WATER/AIR/MIX COOLING235000×3500×2500
16  V-1.8/(18-23)-2101.8~2.32000-2590280WATER/AIR/MIX COOLING126500×2525×2200
17  D-1.45/(20-35)-2502.0~3.51830-3100280WATER/AIR/MIX COOLING235000×3500×2500
18  V-0.8/(19~35)-2501.9~3.5960~1720160WATER/AIR/MIX COOLING136500×2525×2200
19  VF-1/(25~40)-2502.5~4.01560~2700220AIR COOLING13.54250×2525×2100
20  D-1.45/(40~60)-2504.0~6.03600~5300315WATER/AIR/MIX COOLING235000×3500×2100
21  D-1.3/(50-70)-2505.0~7.03970~5530315WATER/AIR/MIX COOLING235000×3500×2100
22  D-1.3/(60-70)-2506.0~7.04758~5530315WATER/AIR/MIX COOLING235000×3500×2100
23  D-1.2/(40-80)-2504.0~8.04758~5530315WATER/AIR/MIX COOLING235000×3500×2100
24  D-3.5/(7-10)-2500.7~11680~2240550AIR COOLING286600×4300×2500

CNG SUBSTATION COMPRESSOR
CNG substations are built in places where no natural gas pipelines pass through.
The CNG trailer transfers the gas from the mother station to the station and unloads the gas through the gas unloading column.
Gas machines refill cars.
Equipment composition: gas unloading column, sub-station compressor, sequence control panel, storage
Gas cylinder sets, gas dispensers, gas alarm devices, CNG trailers and other equipment.
Covered area: about 1000~1500m²
Way of working:
After natural balance, the direct intake air is compressed and supercharged, and the average working capacity is
More than 1000 square meters
Compressor exhaust volume changes range as trailer pressure drops:
1800-400Nm²/h
NO.TYPEIntake pressure
MPa
CAPACITY
Nm3/h
MOTOR
KW
COOLING WEIGHT(TONS)SIZE
mm
1VF-0.32/(30~200)-2503~20150075AIR5.55538×2134×1680
2VFD-0.32/(30~200)-2503~20150075AIR9.655538×2438×2438
3DFD-0.32/(30-200)-2503~20150075AIR8.54400×2610×2591
4VFD-0.32/(20~200)-2502~20150075AIR9.655538×2438×2438
5VF-0.26/(30-200)-2503~20100055AIR5.55538×2350×2000
6VFD-0.26/(30-200)-2503~20100055AIR9.55538×2350×2438
7ZFD-0.1/(30~200)-2503~2065037AIR8.57000×2700×2700
8ZFD-0.24/(30-200)-2503~20140037×2AIR8.57000×2700×2700
9KR-1500/(20-200)-2502~20150030×2AIR105500×2500×2950
10KR-2000/(20-200)-2502~20200037×2AIR105500×2500×2950
11DFD-3[0.28]/(2-4)[25-200]-2500.2~0.4

2.5~20
540-900
(STANARD STATION AND SUBSTATION)
1300
160

75
AIR12.54050×3450×2100
Detailed Photos

 

After Sales Service

In addition to the high-quality performance of our products, we also attach great importance to providing customers with comprehensive services. We have an independent service operation and maintenance team, providing customers with various support and services, including technical support, debugging services, spare parts supply, renovation and upgrading, and major maintenance. We always adhere to the principle of customer-centrism, ensuring the safe and stable operation of customer equipment. Our service team is committed to providing reliable support for customers' operations 24/7.
 

Training plan

Technical training is divided into two parts: company training and on-site training.
1)Company training
Before the unit is delivered, that is during the unit assembly period, users will be provided with a one-week on-site training by the company. Provide local accommodation and transportation facilities, and provide free venues, teaching materials, equipment, tools, etc. required for training. The company training content is as follows:
The working principle, structure and technical performance of the unit.
Unit assembly and adjustment, unit testing.
Operation of the unit, remote/local operation, manual/automatic operation, daily operation and management, familiar with the structure of each system of the unit.
Routine maintenance and upkeep of the unit, and precautions for operation and maintenance.
Analysis and troubleshooting of common faults, and emergency handling methods.
2) On-site training
During the installation and trial operation of the unit, on-site training will be conducted to teach the principles, structure, operation, maintenance, troubleshooting of common faults and other knowledge of the unit, so as to further become familiar with the various systems of the unit, so that the purchaser can independently and correctly operate the unit. Operation, maintenance and management.

 

Packaging & Shipping

 







Message Type
* Message Content
* Name  
* Phone
* Email