High-Efficient Waste Gas Treatment Granular Activated Carbon Absorption in PP Material

Price Negotiable Compare
Min Order 1 Set
Shipping From Jiangsu, China
Popularity 407 people viewed
Quantity
+-
 

Eascle Environmental Technology(Jiangsu) Co., Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
ECH-20
Lifetime
1 Year
New
ISO
Automatic
Chemical Treatment
PP Domestic High Quality Board
99.99%
Ral7032 / Customized
6000-9000
750 Kg
2.0 Cbm
EASCLE / customized
Wooden Packing & Wooden Pallet
2800*1800*2300mm
Suzhou, China
Product Description
Detailed Photos

 

 

Product Description

Working Principle

1.Adsorption Stage
 
Physical Adsorption:
The waste gas passes through a GAC bed, where organic          pollutants (e.g., VOCs) are trapped on the surface and within the micropores of the GAC through van der Waals forces.


Chemical Adsorption (Optional):
Chemically modified GAC may adsorb specific contaminants through chemical reactions, improving treatment efficiency for targeted pollutants.


 
2.Regeneration Stage
 
Once the GAC becomes saturated with adsorbed pollutants, it is regenerated to restore its adsorption capacity.

Common regeneration methods include:
Thermal Regeneration: High-temperature desorption volatilizes the adsorbed contaminants, which are then treated or collected.
Steam Stripping: Steam passes through the GAC bed, desorbing the pollutants for recovery or destruction. 
Vacuum Desorption: Avacuum reduces the pressure, lowering the boiling points of the adsorbed pollutants for removal.
 
Product Feature

Working Process

1.Waste Gas Collection
Polluted air is collected from the emission source via a ducting system and directed into the GAC adsorption tower.
 
2.Pre-treatment (Optional)
If the waste gas contains particulates, oils, or excessive moisture, pre-treatment devices (e.g., filters, scrubbers) are used to protect the GAC from clogging or degradation.
 
3.Adsorption Stage
The waste gas flows through the GAC bed in the adsorption tower, where organic pollutants are adsorbed.
Clean air exits the tower and is discharged into the atmosphere after meeting regulatory standards.
 
4.Breakthrough Monitoring
Sensors monitor the adsorption performance. When the GAC is saturated (breakthrough point), the system signals the need for regeneration.
 
5.Regeneration Stage
The saturated GAC is regenerated in situ (within the system) or ex situ (removed and regenerated elsewhere).
 

 

Product Parameters
 
Parameters/ModelOverall dimensions(mm)
Length*Width*Height
Rated air volume/Airflow (m³/h)CMHPurification efficiencyEquipment materialEquipment weight (kg)Activated carbon
filling amount (m
³)
ECH-61800*1800*18002000-300099.99%PP domestic high quality board*10mm4680.6 
ECH-132800*1800*18003000-600099.99%PP domestic high quality board*10mm6001.3 
ECH-202800*1800*23006000-900099.99%PP domestic high quality board*10mm7502.0 
ECH-303200*2000*25009000-1200099.99%PP domestic high quality board*10mm8653.0 
ECH-423400*2000*300012000-1500099.99%PP domestic high quality board*10mm9964.2 
Message Type