Laboratory 300c High Temperature Heating System Hot Oil Heater

Price $6500.00 Compare
Min Order 1 Set
Shipping From Jiangsu, China
Popularity 285 people viewed
Quantity
+-
 

Nanjing Ningkai Instrument Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
Support
1 Year
Circulating Heating Machine
CE
Closed Pipeline
Xinchen
Rt ~ 300c
Air Cooling or Water Cooling
XINCHEN
Export Plywood Box
650*550*850mm
China
8419899090
Product Description
Product Description

XINCHEN specializes in the production of R&D heating systems with a temperature control range of room temperature to 300ºC.

The heat exchange area is large, the temperature rise and fail is fast, and the heat transfer oil demand is small.

Only need to connect the equipment with heat transfer oil inlet and outlet of reactor device, from the top of the equipment liquid inlet add in the heat transfer medium, turn on add liquid button can easily remove the air in the system, set the temperature requirements, the system can run automatically.

Widely used in chemical, pharmaceutical or biotechnology reactor, control mixing tank temperature, metal(glass) double layer reactor, thermal test platform, constant temperature control of material and equipment.

Product Parameters
ModelTemp. range(ºC)Pump flow(L/min)Pressure(bar)Heating(KW)Cooling Capacity(KW)
300ºC200ºC100ºC50ºC
HR-3035WRT ~ 300ºC200.83.53.53.51.50.5
HR-3050WRT ~ 300ºC251.055540.8
HR-3100WRT ~ 300ºC351.5101010101.2
HR-3150WRT ~ 300ºC501.5151515152.5
HR-3200WRT ~ 300ºC802.0202020153.2
HR-3250WRT ~ 300ºC1102.0252525205.5
Working Principle

Product Features

1. HR series of products can be carried out continuous heating from room temperature to 300 degrees. 
2. The circulation pipeline is enclosed, high temperature without volatile oil mist, oil will not be oxidation and browning.
3. With the function of correcting internal circulation temperature probe PT100 probe.
4. The liquid circulation system is closed, the system with expansion vessel. The expansion vessel and the liquid circulation is adiabatic, does not participate in the liquid circulation, just connected. Although the temperature of liquid circulation is under the condition of high temperature, medium temperature in expansion vessel is lower than 60 ºC
5. High lift design, to meet the requirements of long-distance transportation conducting medium.