XH-SCT-1250
Electronic, Instrument, Position Sensor, Audio, Lighting
Split Core Current Transformer
Single
Indoor
Measurement
Multilayer Honeycomb Type
Epoxy Resin
Active Type
Combined Type
Capacitive Type
Split Core Current Transformer
0.33V or Ma
UL,ETL,CE,RoHS
Jiangyin spark
Outer Carton with Smaller Inner Box
UL, ROHS, ISO9001: 2008
China(Mainland)
8504
Product Description
Split core Current Transformer SCT XOBA 333mV Secondary
The JIANGYIN SPARK series of split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easy and portable current measurement. An internal precision burden resistor across the secondary winding of the CT provides a safe low voltage output and permits safe opening of the secondary
SPECIFICATIONS :
1,Rated Voltage:0.66KV;
2,Insulation Voltage:5400V
CATIII 600V or CATIV 250V
3,Rated Frequency:50HZ or 60HZ;
4,Operating Temperature:-40ºC to +55ºC;
5,Flame resistance:UL94-V0;
6,Leads:20ft (6m) UL 1015 18awg
7,Certificates:UL2808 and IEC61010-1
Application
Measures AC current flow to electric motors, lighting, air conditioning equipment, etc.Compatible with HVAC temperature control, power management,building automation systems.
Drawing of split core CTs XH-sct-1250

Performance of split core CTs XH-sct-1250
Our hot sales:

The JIANGYIN SPARK series of split core current transformer are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easy and portable current measurement. An internal precision burden resistor across the secondary winding of the CT provides a safe low voltage output and permits safe opening of the secondary
SPECIFICATIONS :
1,Rated Voltage:0.66KV;
2,Insulation Voltage:5400V
CATIII 600V or CATIV 250V
3,Rated Frequency:50HZ or 60HZ;
4,Operating Temperature:-40ºC to +55ºC;
5,Flame resistance:UL94-V0;
6,Leads:20ft (6m) UL 1015 18awg
7,Certificates:UL2808 and IEC61010-1
Application
Measures AC current flow to electric motors, lighting, air conditioning equipment, etc.Compatible with HVAC temperature control, power management,building automation systems.
Model | Input(A) | Max currnet(A) | Output |
XH-SCT-1250 | 0-600A | 600 | mA/0.333VAC/0-5VAC |
Drawing of split core CTs XH-sct-1250

Performance of split core CTs XH-sct-1250
Our hot sales: