AC Vlf Hipot Test Set 0.1Hz Very Low Frequency Cable Testing Equipment up to 80 Kvrms

Price $10000.00 Compare
Min Order 1 Piece
Shipping From Hubei, China
Popularity 395 people viewed
Quantity
+-
 

EP HIPOT ELECTRIC CO., LTD.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
EPVLF-80kV
Strength Testing Machine
1
Electronic Load
LCD
Computer Control
0-100Kg
110V/220V Can Be Customized
80kv
0.1Hz, 0.05Hz and 0.02 Hz (Selectable)
1.1UF @0.1Hz, 2.2UF@0.05Hz, 5.5UF@0.02Hz
220V or at Customized
Less Than 5 %
Peak Voltage Instability Less Than 1%
Indoor or Outdoor -10-+50, 85%Rh.
10kg
22kg
2kg
Microprocessor
Display
Built-in
Over Voltage and Current
Vlf Tester
EP Hipot Electric
Plywood Cases
Control unit: 4kg
Wuhan, China
9030339000
Product Description
VLF AC HIPOT TEST SET
EPVLF-80/1.1


General Information:
VLF stands for Very Low Frequency. VLF is generally considered to be 0.1 Hz and lower, its major application is for testing solid dielectric cable, transformers, motors, generators, switchgear and other electrical apparatus.

A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.


Features:
  • Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.
  • Portable, easy to move.
  • Large LCD can display waveform clearly, and test report can be printed. Built-in printer.
  • The data of current, voltage, and waveform can be sampled at HV side.
  • A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.
  • Closed-loop negative feedback circuit is adopted. No capacity rising during outputting.
  • Over voltage and current protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.

Specifications
Specifications
Peak voltage:80kV
Output frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
Fuse: 20A
Maximum load capacity: 1.1μF@0.1Hz, 2.2μF@0.05Hz, 5.5μF@0.02Hz
Power supply:220V ±10%, 50Hz ±5% (If using a portable generator, make sure the output voltage and frequency are stable. Power >3kW.)
Output voltage accuracy:peak voltage instability ≤1%, frequency instability ≤3%.
Voltage waveform distortion:≤5%.
Output voltage accuracy: peak voltage instability ≤1%, frequency instability ≤3%.
Working environment:indoor or outdoor; -10ºC-+50ºC, 85%RH.
Weight:  Control unit 4kg, HV unit I: 10kg, HV unit II: 22kg, Capacitor 2kg.