ACSR Aluminum Conductor Steel Reinforced DIN Types of ACSR Conductor

Price $5.80 Compare
Min Order 1000 Meters
Shipping From Henan, China
Popularity 401 people viewed
Quantity
+-
 

LUOYANG SANWU CABLE GROUP CO., LTD

VIP   Audited Supplier 10 years
Profile Certified by SGS/BV
ACSR-IEC-ASTM-BS-DIN
Bare
Stranded
Overhead
Aluminium Conductor Steel Reinforced
Bare
Bare
Round Wire
Overhead
ISO9001, CE, CCC, RoHS, OHSAS
Sanwu
ACSR Conductor Cable
Steel or Galvanized Steel
10-800mm2
Low, Medium, High
CSA, IEC, ASTM, DIN, BS, etc.
Overhead, State Grid, Power Station
20 Years
Since 2006
by Express or Sea
20,081mm2
SANWU CABLE
Wooden Drum/Wooden Steel Drum
10-800mm2
Luoyang, Henan, China
76141000
Product Description
LUOYANG SANWU CABLE GROUP with registered capital of 100 million RMB, is a high-tech development company for scientific research, industry producing and
trading, offering a diverse selection of quality wires and cables to industrial customers in more than 50 countries worldwide. The leading products are ACSR, overhead conductor, AAAC, AAC, power cable
 etc.

 
SANWU CABLE owns variously advanced equipment and large quantities of high skilled professionals. With complete management system, advanced production process,
strict testing procedure and reliable product quality, we have successively got IS09001, IS014001,OHSAS18001,TUV Certificate, CCC(China Compulsory Certification),
the national industrial production license and so on.

In terms of quality, it is highly controlled by our company to ensure that all the products we sell meet your requirements and give you reassurance with excellent after-
sale
 service.In terms of service, we are focusing on your need, we concern what you concern and request what you request to provide a more satisfied service.


Product Description
ASTM BS CSA Standard Overhead Aluminium Conductor Steel Reinforced Conductor Cable ACSR
ACSR (Aluminum Conductor Steel Reinforced), consisting of a galvanized steel core, is surrounded byconcentric layers of aluminum wire, and grease if necessary.
Application:
Conductor (AAC and ACSR) have been widely used in power transmission lines with various voltage, because they have such good characteristics as simple structure, convenient installation and maintenance, low cost and large transmission capacity. 
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded 
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced

 Executive Standard:IEC
Code Nam eAreaNum ber of WireWire diaDiam eterLinear Mas sRated StrengthD.c
Res is tanc
Alum iniuSteelTotalAlumSteelCoreCond
mmm ²m m ²m m ²AlStm mm mm mm mk g/k mdaMO/ek m
16162.6718.7611.841.841.845.5364.66.081.7934
25254.1729.2612.302.302.306.91100.99.131.1478
40406.6746.7612.912.912.918.74161.514.400.7174
636310.573.5613.663.663.6611.0254.421.630.4555
10010016.7117614.614.614.6113.8403.834.330.2869
1251256.941321812.972.972.9714.9397.929.170.2304
12512520.41452672.471.925.7715.7503.945.690.2310
1601608.891691813.363.363.3616.8508.336.180.1800
16016026.11862672.802.186.5317.7644.957.690.1805
20020011.12111813.763.763.7618.8636.744.220.1440
20020032.62332673.132.437.3019.8806.270.130.1444
25025024.62752273.802.116.3421.6880.668.720.1154
25025040.72912673.502.728.1622.21007.787.670.1155
31531521.83374572.991.995.9723.91039.679.030.0917
31531551.33662673.933.059.1624.91269.7106.830.0917
40040027.74284573.362.246.7326.91320.198.360.0722
40040051.94525473.073.079.2127.61510.3123.040.0723
45045031.14814573.572.387.1428.51485.2107.470.0642
45045058.35085473.263.269.7729.31699.1138.420.0643
50050034.65354573.762.517.5230.11650.2119.410.0578
50050064.85655473.433.4310.330.91887.9153.800.0578
56056038.75994573.982.657.9631.81848.2133.740.0516
56056070.963154193.632.1810.932.72103.4172.590.0516
63063043.66744574.222.818.4433.82079.2150.450.0459
63063079.871054193.852.3111.634.72366.3191.770.0459
71071049.17594574.482.998.9635.92343.2169.560.0407
71071089.980054194.092.4512.336.82666.8216.120.0407
80080034.68357273.762.517.5237.62480.2167.410.0361
80080066.78678473.483.4810.438.32732.7205.330.0362
80080010190154194.342.6113.039.13004.9243.520.0362
90090038.99397273.992.667.9839.92790.2188.330.0321
90090075.09758473.693.6911.140.63074.2226.500.0322
1000100043.210437274.212.808.4142.13100.3209.260.0259
1120112047.3116772194.451.788.9044.53464.9234.530.0258
1120112091.2121184194.122.4712.445.33811.5283.170.0258
12501250102135284194.352.6113.147.94253.9316.040.0232
1250125052.8130372194.701.889.4047.03867.1261.750.0231
   

Executive Standard:ASTM


Code

Size
SectionStrandingDiam eterTotal WeightRated StrengthMaxim um Res is itance
@20°C
AlTotalAlSteelCableSteel
AWG or MCMm m ²m mm mk g/k mk gO/k m
Wren88.379.816×1.331×1.333.991.3333.83403.4017
Turkey613.315.486×1.681×1.685.031.6853.75402.1135
Sw an421.1524.716×2.121×2.126.352.1285.48461.3278
Sw anate421.1526.527×1.961×2.616.532.6199.710671.3133
Sparrow233.6239.236×2.671×2.678.032.6713612890.8343
Sparate233.6242.137×2.471×3.308.263.315916500.8251
Robin142.4149.486×3.001×3.009.02317116120.6621
Raven1/053.5162.396×3.371×3.3710.113.3721619870.5243
Quail2/067.4478.656×3.781×3.7811.353.7827324010.416
Pigeon3/085.0299.236×4.251×4.2512.754.2534430060.3304
Penguin4/01071256×4.771×4.7714.34.7743337870.2618
Ow l266.81351536×5.367×1.7916.095.3750743300.2109
Waxw ing266.813514318×3.091×3.0915.473.0943131170.2119
Partridge266.813515726×2.577×2.0016.315.9854751130.21
Oatrich30015217726×2.737×2.1217.276.3661457550.1867
Piper30015218830×2.547×2.5417.787.6269770000.1902
Merlin336.417118018×3.471×3.4717.373.4754439310.168
Linnet336.417119826×2.897×2.2518.316.7468967300.1663
Oriole336.417121030×2.697×2.6918.828.0778478650.1654
Chickadee397.520121318×3.771×3.7718.873.7764244990.1421
Ibis397.520123426×3.147×2.4419.897.3281474880.1411
Lark397.520124830×2.927×2.9220.478.7792792020.1401
Pelican47724225518×4.141×4.1420.684.1477153470.1184
Flicker47724227324×3.587×2.3921.497.1691477900.1178
Haw k47724228126×3.447×2.6721.798.0397788800.1171
Hen47724229830×3.207×3.2022.439.611112107830.1165
Heron50025331230×3.287×3.2822.969.841162110900.1141
Osprey556.528229818×4.471×4.4722.334.4789962330.1014
Parakeet556.528231924×3.877×2.5823.227.73106789990.101
Dove556.528232826×3.727×2.8923.558.661140100190.1007
Eagle556.528234830×3.467×3.4624.2110.391298126060.1001
Peacock60530734624×4.037×2.6924.218.03116197710.0928
Squab60530735726×3.877×3.0124.549.041240110180.0925
Teal60530737630×3.6119×2.1625.2510.821398135670.0919
Duck60530734654×2.697×2.6924.218.071158102100.0944
Kingbird63632234018×4.781×4.7823.884.78102871280.0895
Rook63632236424×4.147×2.7624.828.281219102980.0883
Grosbeak63632237526×3.977×3.0925.159.271302114270.0897
Egret63632239630×3.7019×2.2225.8811.11471143020.0876
Goose63632236454×2.767×2.7624.848.281218107300.0898
Flamingo666.633838224×4.237×2.8215.48.461278107510.0843
Gull666.633838254×2.827×2.8225.388.461276111400.0587

Executive Standard:BS


Code name
Nominal Aluminium
Area

Stranding and wire diameter
Sectioanal area of
aluminium
Total Sectional area
Overall Diameter

Linear mass
Calculate Breaking LoadCalculate D.C
Resistance at20°C
Final Modulus
of
elasticity
Corefficient of l inear expansion
mm²AluminiumSteelmm²mm²mmkg/kmdaMO/kmhhar/°C
Mole106/1.501/1.5010.6212.394.50434142.706790019.1×10-6
Squirrel206/2.111/2.1120.9424.436.33857881.368790019.1×10-6
Gopher256/2.361/2.3626.2430.627.081069611.093790019.1×10-6
Weasel306/2.591/2.5931.6136.887.7712811460.9077790019.1×10-6
Fox356/2.791/2.7936.6642.778.3714913200.7822790019.1×10-6
Ferret406/3.001/3.0042.4149.489.0017215200.6766790019.1×10-6
Rabbit506/3.351/3.3552.8861.710.0521418350.5426790019.1×10-6
Mink606/3.661/3.6663.1873.7110.9825521800.4545790019.1×10-6
Shunk6012/2.597/2.5963.27100.3012.9546553000.45671050015.3×10-6
Beav er706/3.991/3.9974.8287.2911.9730225700.3825790019.1×10-6
Horse7012/2.797/2.7973.37116.213.9553861200.39361050019.1×10-6
Raccon756/4.101/4.1079.292.412.3032027200.3622790015.3×10-6
Otter806/4.221/4.2283.8897.8613.9833928800.3419790019.1×10-6
Cat906/4.501/4.5095.4111.3015.9038632700.3007790019.1×10-6
Hare1006/4.721/4.72105.0122.5017.5042536000.2733790019.1×10-6
Dog1006/4.727/1.57105.0118.514.1539432700.2733750019.8×10-6
Hy ena1007/4.397/1.93105.8126.214.5745040900.2712750019.8×10-6
Leoperd1258/5.287/1.75131.3148.115.8149240700.2184750019.8×10-6
Coy otte12526/2.547/1.91132.1152.215.8952246400.2187850017×10-6
Congar12518/3.051/3.05130.3137.515.2541929800.2189660021.2×10-6
Tiger12530/2.367/2.36131.1161.716.5260258000.2202800017.8×10-6
Dingo15018/3.351/3.35158.7167.516.7550635700.1815660021.2×10-6
Wolf15030/2.597/2.59158.1194.918.1372669200.1828800017.8×10-6
Caracal17518/3.811/3.61184.3194.518.0558741100.1563660021.2×10-6
Ly nx17530/2.797/2.79183.4226.219.5384279800.1576800017.8×10-6
Jaguar20018/3.861/3.86210.6222.319.3067146550.1367660021.2×10-6
Panther20030/3.007/3.00212.1261.521.0097492250.1363800017.8×10-6
Lion22530/3.187/3.18238.5294.222.261095100600.1212800017.8×10-6
Bear25030/3.357/3.35264.0325.623.451213111100.1093800017.8×10-6
Goat30030/3.717/3.71324.3400.025.971489135700.0891800017.8×10-6
Sheep35030/3.997/3.99374.1461.427.931718155900.07704800017.8×10-6
Antilope35054/2.977/2.97373.1421.526.731411118200.07727690019.3×10-6
Bison35054/3.007/3.00381.8431.327.001444120900.07573690019.3×10-6
Deer40030/4.277/4.27429.3529.528.891971178500.0674800017.8×10-6
Zebra40054/3.187/3.18428.9484.528.621621131900.0674690019.3×10-6
Elk45030/4.507/4.50477.0588.331.502190198200.06056800017.8×10-6
Camel45054/3.357/3.35475.2536.830.151797145700.06073690019.3×10-6
Moose50054/3.537/3.53528.7597.231.771999161100.0547690019.3×10-6
Finch55054/3.6519/2.29564.7642.933.352243180700.0512680018.3×10-6


(ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Material Standard:
1) The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997 (equivalent to IEC 60889:1987)
2) The zinc coated steel wire used for ACSR confirms to IEC 60888:1987
3) Production can be arranged according to customers' requirement such as material standard etc.
4) We can also produce products according to the Standard of BS215, ASTM B232, and DIN48204.Technical characteristics

Certifications
ISO9001:2008, OHSAS, CCC, TUV Certifications.

Package&Shipping:
For Package: Support to pack as rolls, or with wooden drum or wooden steel drums. 
Shipment terms: 
By FOB, CFR or CIF by sea.
By DHL, UPS, Fedex express etc are also available.
Our Services
Luoyang Asian Sun Industrial Group Co., Ltd, a professional wires and cables manufacturer for 6 years in China. Asian Sun attends International Exhibitions every year, we mainly produce power cables, control cables, aerial overhead cables(ABC, AAC ACSR and AAAC cables) and solar pv cables etc. Standards Supported: ASTM, BS, CSA, IEC, DIN and GB etc.
1. Factory: 200,081 square meters, available for OEM;
2. Lead time: 5-7 working days after payment received;
3. Authentication: TUV, OHSAS, CCC, CQC, ISO9001:2008;
4. Payment terms: T/T, L/C, O/A;
5. Guarantee: 20 years;
6. QC inspection: Strict inspection before delivery;
After-sales Service:
1. All our cables will be tested well in production and before delivery.
2. Please contact us if any problem, we will respond within 24 hours.
Customers Visiting:
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA