GDY-1A+
Lifetime Technical Support
1 Year
(14000~15000)J/K
0.001 K
≤60j/G
10 ºC~35 ºC
≤0.2% (Grade C)
20 MPa
31
Less Than 85%
Less Than 150W
Gold
Standard Wooden Case
600*460*430mm
Chongqing, China
9031809090
Product Description
ASTM D240 Automatic Calorific Value Bomb Calorimeter
Introduction:Parameters | GDY-1A | GDY-1A+ | GDY-1C |
Picture | ![]() | ![]() | ![]() |
Test mode | Manual | Semi-auto | Automatic |
Control model | In-build computer | Micro-computer | Computer |
Packing Size | 72*59*51 47*47*28 | 71*56*50 46*37*26 | 69*55*48 45*37*25 58*52*84 |
Gross Weight | 40kg | 33kg | 63kg |
1.It is suitable for the determination of water free oil products (gasoline, jet fuel, diesel oil and fuel oil, etc.) and combustible material such as coal, coke, paraffin wax content determination of calorific value.
2.It is a high grade instrument with the advantages of automatic, efficient, safe, high precision, fast test speed and easy to use.
Features:
1.The instrument uses a single-chip control technology, color LCD display, high-precision temperature sensor and high-performance A / D conversion device, consisting of a high degree of automation, screen effect is good, easy to use, convenient intelligent data compilation instrument.
2.The instrument is fully automated in the testing process, after the sample in place, correct input various parameters automatically without manual intervention to complete each test process; you can print measurement data directly on the A4-format printer configuration after the end of the trial.
3.This instrument adopts the self sealing type oxygen bomb, all the structure is made of stainless steel, and the strength is enough to withstand the pressure test of 20MPa at room temperature.
4.The inner tube of the instrument is made by stainless steel sheet, section of pears, put the barrel of water was 3000 grams, water cylinder with electric blender, to ensure that the inner tube water bath temperature uniformity.
5.The instrument of the external water jacket is a double container and experiment when filled with water, through the water jacket mixer to cylinder in uniform temperature, formed to meet the test requirements of the constant temperature environment.
Specifications:
Heat capacity | (14000 ~ 15000)J/K |
Temperature resolution | 0.001 K |
Thermal error | ≤60J/g |
Temperature measurement range | 10 ºC~35 ºC |
Repeatability error | ≤0.2% (Grade C) |
Pressure endured by Oxygen bomb | 20 MPa |
Ambient temperature | 15 ºC~28 ºC (room temperature), The temperature fluctuation during each test should be not more than 1 ºC |
Storage Temperature data | 31 |
Ambient humidity | less than 85% |
Power supply | AC(220±5%)V,50Hz |
Total power consumption | less than 150W |
Dimensions | 600 mm × 460 mm × 430 mm (length × width × height, PC is not included) |
Note: If the test sample is pulverized coal samples, in order to obtain better test results, we recommend separately of the company's private press cake machine. |
Full set:
No. | Name | Unit | Quantity |
1 | GDY-1A+ Main unit (including single chip, oxygen bomb, water jacket, water bucket, stirrer) | set | 1 |
2 | Oxygen bomb head holder | set | 1 |
3 | Oxygen bomb seat | set | 1 |
4 | Temperature sensor | piece | 1 |
5 | Thermometer(0-50ºC) | piece | 1 |
6 | Stopper for thermometer (silica gel stopper 2 #) | piece | 1 |
7 | Ignition wire (Ф0.1 Nickel-Chromium wire) | meter | 10 |
8 | Crucible | piece | 2 |
9 | Discharging valve | piece | 1 |
10 | Oxygen decompression device | piece | 1 |
11 | Oxygen pipe | pair | 1 |
12 | O type airproof ring(φ20×2.4mm) | piece | 5 |
13 | O type airproof ring(φ8×1.9mm) | piece | 5 |
14 | O type airproof ring(φ6×1.9mm) | piece | 5 |
15 | Airproof ring (largest O type) | piece | 2 |
16 | Benzoic acid | piece | 10 |
17 | Water aspirator | piece | 1 |
18 | Printing paper | roll | 1 |
19 | Stopping ring for thermometer (1#) | piece | 4 |
20 | Fuse 2A (Φ5×20) | piece | 2 |
21 | Silica gel stopper (7#) | piece | 1 |
Product Details:




What service can our company provide you?
Pre-sale Service:
1. The professional sales team will reply to the inquiry in real time;
2. Customize suitable solutions according to the needs of different customers;
3. Provide product technical parameters/operation manuals and evaluation reports, etc.;
After-sale Service:
1.From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services.
2.Technical Support
(1)Our technical team supports our customers at all time with our long experience, expert advice and the unlimited spirit and always be for providing the best customer service.
(2)Training how to install the machine,you can arrange your engineer to our company to get free training.
(3)If necessary, we can also arrange our engineer to your company for training and commissioning at your cost.
3.The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options.
Contact Us:
Welcome to contact us talk about details if you are interested in ASTM D240 Automatic Calorific Value Bomb Calorimeter.If you want to know more information,Don't hesitation, welcome your inquiry!Price can be negotiated !