Aas-D Double Beam Atomic Absorption Spectrophotometer with Graphite Furnace

Price $1.00 Compare
Min Order 1 Set
Shipping From Chongqing, China
Popularity 206 people viewed
Quantity
+-
 

Delta Technology (Chongqing) Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
AAS-D
Response on Customers' Questions Within 12 Hours.
12 Months
Metals Analyzer
Photoelectric Colorimetry
Computer Screen
Metal
50±1HZ
Automation
Storage
0-100Kg
AC220V±22V
Non-Customized
Double Beam Atomic Absorption Spectrophotometer
190-900nm
0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
0.004ug/Ml(Cu)
1800 Lines/mm
8
Flame Method Atomic Absorption Spectrophotometer
Graphite Furnace, Lamps
English
Yes
Automatic
10 Days
by Sea or Air
Yes
Engineer Is Availabe for Oversea Training
Delta
Packed in Veneer Case
700mm*550mm*450mm, 75Kg
China Mainland
9031809090
Product Description
AAS-D Double Beam Atomic Absorption Spectrophotometer with Graphite Furnace
 
 
Product Description

Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional)

Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term. 

Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp

Position adjusting: the best height of the flame burner and can automatically set the front and rear positions

Fully automated wavelength scanning and peak searching

Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout

Deuteriu lamp and self-absorption background regulation 

Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called

Measuring method: flame absorption method and emission method

Result printing: parameter printing, data result printing and diagram printing

Product Parameters
Wavelength range:190 - 900nm
Spectral bandwidth:Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
Accuracy of the wavelength:±0.15nm
Receptivity of the wavelength: ≤0.04nm
Base line stability:≤0.002A/30min (Cu)
Characteristic viscosity:0.02μg/ml/1% (Cu)
Checking limit:0.004μg/ml (Cu)
Preciseness:0.5%
Grating:1800 lines/mm
Inflamer:All-metal titanium burner
Atomizer:Effective glass atomizer
Lamp stand:Eight lamps 
D2 background correction ability:When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method
Size and weight:700mm×550mm×450mm  75Kg
Power source:220V±22V  AC

 

Features

Complete automatic controlling system
Advanced graphite furnace temperature controlling technology
Safe, reliable and convenient flame system