Accurate Arc Resistance Properties Analyzer for Electrical Insulation Testing

Price $10000.00 Compare
Min Order 1 Set
Shipping From Jilin, China
Popularity 486 people viewed
Quantity
+-
 

Changchun Intelligent Instrument Equipment Co.,Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
NDH-15K
Online
1 Year
58kg
80kg
780*770*830mm
1set
ZNYQ
Standard Wooden Packing
670*660*590mm
China
9024800000
Product Description
Product Description

Arc Resistance Tester NDH-15K
NDH-15KImmerse yourself in the unparalleled realm of precision testing with our Arc Resistance Test System! Meticulously engineered, this top-tier system is designed to meet the exacting demands of electrical insulation material examination. As a pinnacle of excellence, it stands as a testament to our commitment to innovation and quality in testing equipment.,it's sthe quintessential choice for analyzing electrical insulation materials. It expertly evaluates a wide range of materials including plastics, films, resins, mica, ceramics, glass, insulating paints, and a multitude of other insulating materials. This ensures a superior arc resistance evaluation. Moreover, it is an indispensable asset for product testing and for exploring the electrical properties of innovative materials, truly a must-have for any serious testing laboratory.

Application area

PCB
Photovoltaic Film Materials
PTFE, ABS, Nylon, and Other Plastics
Film Material
Insulating Paint
Mica Materials
Ceramic, Glass Fiber, etc.

 
Detailed Photos

Functional features

Our cutting-edge insulation materials exhibit remarkable resistance to degradation caused by high-voltage arc activity. Typically, a standard arc flame initiates carbonization on the material's surface, transforming it until it becomes conductive. The duration for the arc to extinguish is precisely measured in seconds. Utilizing two tungsten electrodes placed at a specific interval on the sample plate,the arc begins intermittently, progressively shortening until it forms a continuous arc as the current increases. The material faces increasingly severe arc conditions, leading to eventual failure. The resistance to arcs is essential for insulating materials in high-voltage switches or low-voltage high-current switches, regularly encountering arcs during usage. Only materials demonstrating exceptional arc resistance are suitable.
In the realm of electrical and electronic devices, insulating materials exposed to high-voltage, low-current arc discharges exhibit distinctive surface damage variations near the arc. These discharges cause localized thermal and chemical deterioration and corrosion, eventually creating a conductive pathway on the material. Once a conductive channel forms, the material is deemed to have failed the test.
The Arc Resistance Tester is aligned with prestigious standards such as GB1411, IEC61621, ASTMC495, and UL746A, making it an essential instrument for conducting simulated safety testing procedures. It ensures your testing processes adhere to the highest international benchmarks.
Engineered with precision to meet rigorous standard requirements, the arc resistance tester boasts comprehensive electrical schematics and high-precision electrodes. This ensures accurate and reliable testing outcomes every time.

Product Parameters
Arc on/off time errorAll program segments are superior±1msVoltage regulator capacity1kVA
Rated test voltage12.5kVMaximum test voltage15kV
Electrode pressure on sample(0.5±0.05)NElectrode materialTungsten bars
Test voltage accuracy<1.5%Current measurement accuracy<1.5%
Distance between electrodes(6.35±0.1)mm(IEC) (6.0±0.1)mm(ASTM)Ambient temperature(23±2)ºC
Ambient humidity(50±5)%Power supply220V±5%  50Hz  10A
Program segmentArc current mAArc on&off time /sDuration of each program segment/sTotal test time/s
IEC 61621ASTM D495
1101/8son 7/8s off1/8son 7/8s off6060
2101/4s on 3/4s off1/4s on 3/4s off60120
3101/4s on 1/4s off1/4s on 1/4s off60180
410Continuous power on60240
520Continuous power on60300
630Continuous power on60360
740Continuous power on60420

Note:Ensure all instruments and equipment are properly grounded, maintaining grounding resistance at ≤4Ω to guarantee safety and optimal performance. ,The Supply and Demand parties agree that the supplier will provide technical specifications while the demander is responsible for establishing their own grounding system. This synergy ensures a seamless and effective testing setup.