ARD2-25/C
Class 0.5
AC/DC85-265V
45-65Hz
1600-160000imp/Kwh
Acrel
China
Product Description
ARD series intelligent motor protector (hereinafter referred to as protector) can perform various conditions such as start timeout, overload, phase failure, unbalance, underload, ground/leakage, blockage, short circuit and external fault during motor operation. Protection, and SOE fault event recording function, convenient for on-site maintenance personnel to find the cause of the fault. Suitable for coal, petrochemical, smelting, electric power, ships, and civil construction. The protector has RS485 remote communication interface, DC 4 ~ 20mA analog output, and PLC, PC and other control machines form a network system. Remote monitoring of motor operation.
Technical parameters | Technical indicators | |||
Auxiliary power supply | AC85-265V/DC100-350V | |||
Rated working voltage of the motor | AC220V / 380V / 660V,50Hz / 60Hz | |||
Rated operating current of the motor | 1A(0.1A~999.9A) | Small special current transformers | ||
5A(0.1A~999.9A) | ||||
1.6A(0.4A~1.6A) | ||||
6.3A(1.6A~6.3A) | ||||
25A(6.3A~25A) | ||||
100A(25A~100A) | ||||
250A(63A~250A) | Special current transformers | |||
800A(250A~800A) | ||||
Relay output contactor, rated load capacity | 4 Channel, AC250V, 3A | |||
Switching input | 2 channels, opto-coupler isolation (Optional K code) | |||
Communication | RS485(Modbus RTU) | |||
Environment | Working temperature | -10ºC~+55ºC | ||
Storage temperature | -20ºC~+65ºC | |||
Relative humidity | 5%~95%(No condensation) | |||
Altitude | ≤2000m | |||
Pollution levels | Class 2 | |||
Protection level | Main module IP20 | |||
Installation category | Class III |
Technical parameters | Technical specification | |
Auxiliary power supply of protector | AC85V~265V/DC100V~350V, power consumption ≤7VA | |
Rated working voltage of motor | AC380V/AC660V, 50H/60Hz | |
Rated working current of motor | 1A (0.1 ~9999) | Small specific current transformer |
5A (0.1 ~9999) | ||
1.6A (0.4A-1.6A) | ||
6.3A (1.6A~6.3A) | ||
25A (6.3A~25A) | ||
100A (25A~100A) | ||
250A (63A-250A) | Specific current transformer | |
800A (250A~800A) | ||
Relay output contactor, rated load capacity | 4-way, AC250V, 3A, DC30V, 3A | |
Switching input | 2-way, optical isolation | |
Communication | RS485 Modbus | |
Volume of SOE event recorder | 8 events | |
Environment | Working temperature | -10ºC-55ºC |
Storage temperature | -20ºC-65ºC | |
Relative humidity | 5%-95%, no dew | |
Altitude | ≤2000m | |
Class of pollution | 2 | |
Protection level | IP20 |
Rated current of current transformer, A | Ratio setting | Number of turns at the primary side of transformer | Range of setting current Is, A | Power of motor, kW |
1 | Yes | 5 | 0.1~9999 | 0.12~440 |
5 | 1 | 0.1~9999 | 0.12~440 | |
1.6 | No | 1 | 0.4~1.6 | 0.12~0.55 |
6.3 | 1 | 1.6~6.3 | 0.75-2.2 | |
25 | 1 | 6.3~25 | 3~11 | |
100 | 1 | 25~100 | 15-45 | |
250 | 1 | 63~250 | 55~132 | |
800 | 1 | 250-800 | 160-440 |
Additional function | Code | Additional function | Code |
Communication interface | C | 2-way switching input, 1-way relay output (programmable 3) | K |
Leakage protection | L | SOE event recorder | SR |
Analog output 4-20mA | M | Alarm output (programmable 2) | J |