Acrel Support Over-Voltage Over-Current Di Linkage and Other Alarm Output Multi-Channel Three Phase Power Meter Adw200-D16-1s

Price $140.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 331 people viewed
Quantity
+-
 

ACREL CO., LTD.

VIP   Audited Supplier 6 years
Profile Certified by SGS/BV
ADW200-D16-1S
2 Years
Direct Connected
Three-Phase Four-Wire
Electronic Meter
Terminal
Acrel
China
Product Description
Product Description

ADW200 rail-type multi-circuit power meter is mainly used for various three-phase power parameter measurement and active and reactive power measurement of low-voltage network. It can select current input of up to four circuits at the same time. It has RS485 communication and 470MHz wireless communication functions. It can also be used with a variety of expansion modules to facilitate users to monitor, collect and manage electricity consumption. It can be flexibly installed in the distribution box to achieve sub-item power measurement, statistics and analysis of different areas and different loads.

Product Parameters
Auxiliary power
 
AC/DC 85~265V; Consumption≤10VA;


Input
Frequency
45~65Hz;
Voltage
AC 3×220V/380V; Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s; Power consumption: ≤ 0.5VA;
Current
AC 5A,100A,400A,600A;(External opening transformer); Power consumption: ≤ 0.5VA; Overload: 1.2 times of rated value (continuous);
10 times of rated value / 1s;
Measurement Accuracy
Frequency 0.05Hz, voltage,current Class 0.5; 2-31st harmonic accuracy: ± 1%; Active electric energy level 1, reactive electric
energy level 2;
Features
Pulse Output
Output mode: optocoupler pulse with open collector;
Communication
RS485,Modbus-RTU; Baud rate 1200~38400;
Switching Input
Dry contact input,Built in power supply;
Switching Output
Output mode: Relay normally open contact output; contact rating: AC 250V/3A DC 30V/3A;
Switching Module
Power
RJ45 interface,DC 12V,Power consumption≤1W;
Communication
RJ45 interface,Modbus-RTU;(Communication with the main Part)
Switching input
Dry contact input,Built in power supply;
Switching output
Output mode:Relay normally open contact output; contact rating:AC 250V/3A DC 30V/3A;
Temperature and leakage module
Power
RJ45 interface,DC 12V,Power consumption≤1W
Communication
RJ45 interface,Modbus-RTU;(Communication with the main Part)
Temperature measurement
-20~100ºC;
Leakage measurement
10~3000mA;
Measurement accuracy
temperature ±2ºC,Leakage1.0%;
Safety
Power frequency withstand voltage
>AC 2kV/1min;
Insulation resistance
>100MΩ;
Environment
Working temperature: -20ºC~+60ºC; Storage temperature: -40ºC~+70ºC; Relative humidity: ≤95% No condensation; Altitude: ≤2500m;
Electromagnetic compatibility
Better than grade 3;